Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical research study
Current Issue
Editorial Board
Literature Review
Narrative review
Original Article
Research Article
Review Article
Short Report
Surgical techniques
Systematic Review and Meta-Analysis
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical research study
Current Issue
Editorial Board
Literature Review
Narrative review
Original Article
Research Article
Review Article
Short Report
Surgical techniques
Systematic Review and Meta-Analysis
View/Download PDF
59 (); 27-29
doi:
10.1016/j.jor.2024.08.001

Translate:

Short-term outcomes with routine use of size ≥40 femoral heads in THA: A retrospective cohort study

Author affiliations
Loyola University Health System, Department of Orthopaedic Surgery and Rehabilitation, Maywood, IL 60153, USA
Article History
Corresponding author(s)

⁎Corresponding author: Whisper Grayson. whisper.grayson@luhs.org

Article tools · PDF & citations

Abstract

Abstract

Using larger femoral heads during total hip arthroplasty (THA) may result in a more stable hip. Greater volumetric wear and frictional torque, however, may result in increased postoperative complications. The purpose of this study was to compare outcomes of patients with femoral head size ≥40 mm compared to those with femoral head size <40 mm.

A retrospective chart review of 504 THAs performed by a single surgeon at a single institution from 2009 to 2016 was conducted. Following exclusions, 131 THAs were identified with femoral heads ≥40 mm and 348 THAs were identified with femoral heads <40 mm. In addition to demographic data, all postoperative complications were recorded. Plain radiographs were used to rule out/in periprosthetic osteolysis and/or acetabular loosening. Chi-square tests and Student's t-tests were used to compare categorical and continuous variables, respectively.

Mean follow-up period for the entire cohort was 5.5 years. Complications with ≥40 mm femoral heads included 1 superficial infection and 1 deep periprosthetic joint infection (PJI). There were no cases of dislocation, osteolysis, acetabular loosening, or trunnionosis. In contrast, complications with <40 mm femoral heads included 9 dislocations and 7 PJIs.

The routine use of large femoral heads (≥40-mm) during THA appears to be a safe option for patients at short-term clinical follow-up. Notably, 0 patients had a clinical course complicated by dislocation, osteolysis, acetabular loosening, or trunnionosis.

Level III Retrospective Cohort Study.

Keywords

  • Femoral head size
  • Total hip arthroplasty
  • Postoperative complications
  • Dislocation
  • Revision
Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

Despite the high success rate of total hip arthroplasty (THA), postoperative complications and revision surgery remain potential outcomes.1,2 This places a strain on the healthcare system, with an economic burden of approximately 1 billion dollars due to revision THA.1,3,4 As the rate of THA continues to crescendo, it is predicted that this number will double over the next decade.1,3,4

The most common early cause of THA failure is dislocation, with incidence ranging from <1 % to >5 %.5–7 In an effort to combat this, previous literature has described the use of femoral head size ≥40 mm during THA.8–11 It has been suggested that a larger femoral head size improves hip stability, provides greater range of motion, and lowers dislocation rates.8–11 Despite these potential benefits, however, it has also been well-described that use of larger femoral heads increases volumetric wear and frictional torque that may result in increased acetabular cup loosening.12–18 Aseptic loosening is one of the most common causes of late revision THA and is closely linked to component wear.19,20 Previous studies have correlated increased wear with increased diameter of femoral heads.13,14 Additionally, prior biomechanical studies have also shown minimal benefit to using heads larger than 36 mm.21 More recent studies, however, have shown little association of increased wear with larger femoral heads.22,23

With varying reports in the current landscape of orthopaedic literature, as well as a clear lack of consensus regarding optimal femoral head use during THA, further investigation is needed. The primary aim of this study was to evaluate postoperative complications in patients who underwent THA with large femoral heads sized ≥40 mm and compare them to a control cohort where femoral heads <40 mm was used. Complications of interest included infection, dislocation, osteolysis, acetabular loosening, and trunnionosis. Secondary aims included comparing implants, primarily the type of offset liner, used in each cohort.

2

2 Methods

2.1

2.1 Patient selection

Following Institutional Review Board (IRB) approval, a retrospective chart review of 504 consecutive THAs performed by a single surgeon at a single institution from 2009 to 2016 was conducted. All THAs where metal-on-metal components were used were excluded (n = 25). Following exclusions, 131 THAs where size ≥40 mm femoral head were included, while 348 THAs where femoral heads <40 mm were included.

2.2

2.2 Descriptive and outcome data

Implants used were Summit Tapered Hip System (DePuy Synthes Companies; Warsaw, IN) and the Pinnacle Acetabular Cup System (DePuy Synthes Companies; Warsaw, IN). Descriptive data including age, sex, and BMI were collected for the entire cohort. Postoperative complications of interest included superficial infection, deep periprosthetic joint infection (PJI), dislocation, osteolysis, acetabular loosening, and trunnionosis. Plain radiographs were utilized to evaluate for periprosthetic osteolysis and component loosening. All cases were performed via the posterior approach and standard perioperative rehabilitation protocols were implemented. ≥40 mm heads were used in all cases where the acetabular component allowed for it or where the cup size was ≥56. Offset liners were routinely utilized to maximize polyethylene thickness.

2.3

2.3 Statistical analysis

Categorical variables were statistically compared using chi-square tests, while continuous variables were compared using the student's t-test. All statistics were completed using SPSS version 26 (Armonk, New York) with p-values <0.05 considered statistically significant.

3

3 Results

The final cohort available for analysis included 131 THAs (74 metal, 57 ceramic) with femoral head size ≥40 mm or cases and 348 THAs (227 metal, 121 ceramic) with femoral head size <40 mm or controls. Majority (87 %) of the cases were male with a mean age of 71.5 years (σ = 11.9), while most controls were female (72 %) with a mean age of 66.4 years (σ = 12.2). Sex and age both statistically differed between cases and controls (p < 0.0001).

There was a mean follow-up for the entire cohort of 5.5 years (range = 0.01–11.7 years). Cases, or those with femoral heads ≥40 mm, had a total of 2 reported complications at final clinical follow-up and included 1 incident of superficial infection and 1 incident of deep PJI. There were no cases of dislocation, osteolysis, acetabular loosening, or trunnionosis in patients with large femoral heads. Controls, or those with femoral heads <40 mm, had a total of 16 reported complications at final clinical follow-up. This included 9 unique incidents of dislocation (all in female patients) and 7 unique incidents of deep PJIs.

Regarding those with femoral head size ≥40 mm, majority of offset liners were highly cross-linked +4 neutral (n = 119) with the remaining being +4, 10° face changing (n = 6) or neutral (n = 6). Concerning the offset liners for those with femoral head size <40 mm, majority were highly cross-linked +4 neutral (n = 286) with the remaining being +4, 10° face changing (n = 13) or neutral (n = 49).

4

4 Discussion

The use of large femoral heads (≥40 mm) in THA has been suggested to improve hip stability by providing a greater range of motion and lowering the risk for dislocation.8–11 Concerns exist, however, regarding potential for increased acetabular cup loosening, trunnionosis, and impingement over time.12–18 Despite these concerns, there is a paucity of literature regarding short-to-mid-term follow-up for patients with femoral heads size ≥40-mm. Furthermore, much of the current literature reports varying results with a lack of consensus opinion.

This study examined the short-term outcomes (mean follow-up of 5.5 years) in patients where a large femoral head was used during THA. When compared to the control group, low complication rates were seen with zero incidence of dislocation, osteolysis, impingement, or loosening. This lends support to the increased stability and decreased complications seen with the use of larger femoral heads.

This study aligns with the current literature by aiming to find new ways of reducing the complication and reoperation rates associated with THA. Previous studies have demonstrated increased stability and range of motion, along with lower dislocation rates, with the use of large-sized femoral heads.8,10,11,24,25 Despite these perceived benefits, however, other studies have commented on greater volumetric wear with size 36- and 40-mm femoral heads.14,15 Additionally, there has been cited concern for greater torsional forces at the head-neck junction when using large femoral heads, which may lead to increased rates of trunnionosis.26–28 Studies by Bolland et al. and Dyrkacz et al., showed high failure rates and increased corrosion scores with large femoral heads.29,30 Conversely, other studies showed that large diameter femoral heads have no significant effect at the trunnion-neck junction and are not associated with degree of fretting or corrosion. The results of our short-term study agree with Matthies et al. and Triantafyllopoulos et al., showing no radiographic or clinical signs of trunnionosis at final clinical follow-up.31,32

4.1

4.1 Limitations

This study was limited by the fact that it was a retrospective chart review. All patients and outcomes were identified based on prior surgical procedures performed by a single surgeon from 2009 to 2016. There is possibility for recall bias and complications being under reported by patients. Additionally, we were limited in the number of patients within the cases group or those where large femoral heads ≥40 mm were used (n = 131 hips). Nonetheless, to our best knowledge, this is the largest cohort of large femoral heads currently available amongst peer-reviewed orthopaedic literature. Finally, these outcomes are not necessarily generalizable as all cases were performed by a single fellowship-trained arthroplasty surgeon at a high-volume level-1 trauma center utilizing a single hip prosthesis. External validation is necessary in future study. Although there appears to be a lower rate of dislocation in the cases cohort compared to the controls, there were fewer patients in this group and a lower percentage of females. Both factors may confound our study outcomes. Unfortunately, given the low event rate it was not possible to create a multivariable model to control for confounding factors that may influence dislocation rate.

5

5 Conclusion

The use of femoral heads sized ≥40 mm during THA did not result in osteolysis, acetabular loosening, or trunnionosis in our cohort of patients at short-term clinical follow-up. We also appreciated 0 incidences of dislocation within our study group. The results of this study demonstrated low post-operative complications with the routine use of size ≥40 mm femoral heads during THA.

Funding

No funding was received for this research.

Funding statement

This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.

Conflicts of interest

Authors report no conflicts of interest related to this research.

Author contribution

Steven Ralles: Conceptualization, methodology: validation, formal analysis, Hassan Farooq: investigation, data curation, writing – original draft, Whisper Grayson: writing – review and editing, William Hopkinson: supervision, Nicholas Brown: supervision, writing – review and editing

References

  1. , , , et al . Current epidemiology of revision total hip arthroplasty in the United States: national inpatient sample 2009 to 2013. J Arthroplasty. 2017;32(7):2088-2092.
    [Google Scholar]
  2. , , , et al . Twelve-year risk of revision after primary total hip replacement in the U.S. medicare population. J Bone Joint Surg Am. 2012;94(20):1825-1832.
    [Google Scholar]
  3. , , , et al . Association between hospital procedure volume and risk of revision after total hip arthroplasty: a population-based study within the nordic arthroplasty register association database. Osteoarthritis Cartilage. 2016;24(3):419-426.
    [Google Scholar]
  4. , , , , , . Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am. 2007;89(4):780.
    [Google Scholar]
  5. , , , . Large femoral heads decrease the incidence of dislocation after total hip arthroplasty: a randomized controlled trial. J Bone Joint Surg Am. 2012;94(12):1095-1102.
    [Google Scholar]
  6. , , , , . Is there a benefit to head size greater than 36 mm in total hip arthroplasty? J Arthroplasty. 2016;31(1):152-155.
    [Google Scholar]
  7. , , . Dislocation of primary total hip arthroplasty with 36 and 40-mm femoral heads. Clin Orthop Relat Res. 2006;453:153-155.
    [Google Scholar]
  8. , , , , , , . Early- and late-term dislocation risk after primary hip arthroplasty in the medicare population. J Arthroplasty. 2010;25(6):21-25.
    [Google Scholar]
  9. , , , . Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear. HSS J. 2012;8(3):270-274.
    [Google Scholar]
  10. , , , , . The effect of femoral component head size on posterior dislocation of the artificial hip joint. J Bone Joint Surg Am.. 2000;82(9):1300.
    [Google Scholar]
  11. , , , , , , . Large diameter femoral heads on highly cross-linked polyethylene: minimum 3-year results. Clin Orthop Relat Res. 2006;447:53-59.
    [Google Scholar]
  12. , , , . Large metal heads and highly cross-linked polyethylene provide Low Wear and complications at 5-13 years. J Arthroplasty. 2018;33(7):2187-2191.
    [Google Scholar]
  13. , , , , , . Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36- vs 28-mm femoral heads. J Arthroplasty. 2007;22(6):125-129.
    [Google Scholar]
  14. , , , , , . Femoral head size and wear of highly cross-linked polyethylene at 5 to 8 years. Clin Orthop Relat Res. 2009;467(12):3290-3296.
    [Google Scholar]
  15. , , , . Wear and osteolysis of highly crosslinked polyethylene at 10 to 14 Years: the effect of femoral head size. Clin Orthop Relat Res. 2016;474(2):365-371.
    [Google Scholar]
  16. , , , . Current concepts of using large femoral heads in total hip arthroplasty. Hip Pelvis. 2016;28(3):134-141.
    [Google Scholar]
  17. , , , , , , . Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty. J Bone Joint Surg Am. 2007;89(10):2212-2217.
    [Google Scholar]
  18. , , , et al . The 2012 john charnley award: clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA. Clin Orthop Relat Res. 2013;471(2):393-402.
    [Google Scholar]
  19. , , , , , . Reasons for revision hip surgery: a retrospective review. Clin Orthop Relat Res. 2004;429(429):188-192.
    [Google Scholar]
  20. , , , et al . The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis. J Bone Joint Surg Am. 2011;93(8):716-722.
    [Google Scholar]
  21. , , , , , . Biomechanics of large femoral heads. Clin Orthop Relat Res. 2004;429:102-107.
    [Google Scholar]
  22. , , , . Large metal heads and highly cross-linked polyethylene provide Low Wear and complications at 5-13 years. J Arthroplasty. 2018;33(7):2187-2191.
    [Google Scholar]
  23. , , , . Wear and osteolysis of highly crosslinked polyethylene at 10 to 14 years: the effect of femoral head size. Clin Orthop Relat Res. 2015;474(2):365-371.
    [Google Scholar]
  24. , , , , , . Following total hip arthroplasty: femoral head component diameter of 32 mm or larger is associated with lower risk of dislocation in patients with a prior lumbar fusion. Bone Joint Lett J. 2020;102-B(8):1003.
    [Google Scholar]
  25. , , , et al . Effect of femoral head size on risk of revision for dislocation after total hip arthroplasty. Acta Orthop. 2013;84(4):342-347.
    [Google Scholar]
  26. , , , et al . Trunnionosis in total hip arthroplasty: a review. J Orthop Traumatol. 2016;17(1):1-6.
    [Google Scholar]
  27. , , , , , . Taper junction failure in large-diameter metal-on-metal bearings. Bone Joint Res. 2012;1(4):56-63.
    [Google Scholar]
  28. , , , , , , . Trunnion–Head stresses in THA: are big heads trouble? J Arthroplasty. 2015;30(6):1085-1088.
    [Google Scholar]
  29. , , , , , , . High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: clinical, radiological and retrieval analysis. J Bone Joint Surg Br. 2011;93(5):608-615.
    [Google Scholar]
  30. , , , , , . The influence of head size on corrosion and fretting behaviour at the head-neck interface of artificial hip joints. J Arthroplasty. 2013;28(6):1036-1040.
    [Google Scholar]
  31. , , , et al . Material loss at the taper junction of retrieved large head metal‐on‐metal total hip replacements. J Orthop Res. 2013;31(11):1677-1685.
    [Google Scholar]
  32. , , , et al . Otto aufranc award: large heads do not increase damage at the head-neck taper of metal-on-polyethylene total hip arthroplasties. Clin Orthop Relat Res. 2016;474(2):330-338.
    [Google Scholar]
Show Sections