Robotic assisted versus conventional total knee arthroplasty in obese patients: A systematic review and meta-analysis
Article History
-
Received: ,
Accepted: ,
Abstract
Abstract
Total knee arthroplasty (TKA) effectively treats advanced knee osteoarthritis, but obesity increases surgical complexity and complication risk. Robotic-assisted TKA (RA-TKA) may mitigate these challenges by enhancing surgical precision. To date, no study has compared robotic-assisted TKA with conventional total knee arthroplasty in obese patients. Therefore, we aimed to conduct such a comparison.
A systematic review and meta-analysis were performed in accordance with PRISMA 2020 guidelines. A comprehensive search of MEDLINE, Scopus, and Cochrane Central was performed from database inception to July 2025, to identify randomized controlled trials (RCTs) and observational studies with ≥3 months of follow-up, reporting at least one outcome of interest including operative time, complications rates, estimated blood loss (EBL), radiological alignment, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) or Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC).
A total of 5 studies comprising 979 obese patients were included. Of these, 561 patients (57.3 %) underwent C-TKA. The mean age in the RA-TKA group was 66.76 ± 2.28 years, with a mean BMI of 33.39 ± 3.49 kg/m2. Operative time was significantly longer in patients undergoing RA-TKA compared with C-TKA (MD 12.14 min; CI 95 % 7.24 to 17.05; p = < 0.001). Postoperative hip-knee-ankle (HKA) alignment demonstrated significant difference with RA-TKA (MD -0.88°; CI 95 % −1.76 to −0.01; p = 0.05). Conversely, no significant differences were detected across the remaining clinical outcomes.
Our meta-analysis demonstrated that RA-TKA required significantly longer operative time compared with C-TKA, while other perioperative and functional outcomes remained comparable between both techniques.
II.
Keywords
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1 Introduction
In 2000, the World Health Organization (WHO) formally recognized obesity as a global epidemic, continues to rise at an alarming rate, with projections indicate that by 2030, over 40 % of the United States population will be obese (body mass index [BMI] > 30 kg/m2), with more than 10 % classified as severely obese (BMI >40 kg/m2).1,2 This growing epidemic, combined with an aging population, has markedly increased the incidence of knee osteoarthritis, a leading cause of disability worldwide.3,4 In the United States alone, the annual number of total knee arthroplasty (TKA) is projected to approach 1.3 million by 2025, representing a 110 % increase compared with 2014.5 Obesity not only accelerates osteoarthritic degeneration through mechanical overload and chronic inflammation but also heightens the risk of perioperative complications, making it a critical factor influencing both the indication and outcomes of TKA.6
Conventional TKA (C-TKA) has been the gold standard for decades, offering excellent long-term implant survival and functional outcomes.7 However, robotic-assisted TKA (RA-TKA) has emerged as a technological advancement aimed at enhancing surgical accuracy. By integrating preoperative three-dimensional planning with intraoperative real-time feedback and haptic guidance, improve the precision of bone resections and optimize limb alignment.8 Despite its growing adoption, no prior meta-analysis has specifically compared the clinical outcomes of C-TKA and RA-TKA in obese patients.
Existing literature presents mixed results regarding the clinical advantages of RA-TKA over C-TKA. Several studies have reported enhanced radiographic indicators and patient-reported outcomes with robotic-assisted techniques, while others have found negligible differences in functional recovery or complication rates.9 Moreover, operative time remains a critical variable, prolonged duration has been associated with increased risks of surgical site and periprosthetic infections, particularly when procedures exceed 90–120 min.10 In the context of obesity, where excess soft tissue and altered joint biomechanics increase technical difficulty and the risk of suboptimal alignment or wound complications, robotic assistance may offer potential advantages. Nonetheless, the clinical relevance of these benefits and their impact on perioperative outcomes in this high-risk population remain uncertain.
This systematic review and meta-analysis specifically focuses on the obese patient population, synthesizing the best available evidence comparing RA-TKA and C-TKA, focusing on functional and perioperative outcomes as a primary endpoints, while considering its implications for surgical practice and patient care.
2 Methods
2.1 Study selection and eligibility criteria
A systematic review and meta-analysis were performed in accordance with the Cochrane Collaboration Handbook 11 for Systematic Review of Interventions and the PRISMA 2020 guidelines.12 Inclusion in this meta-analysis was restricted to studies that met all the following eligibility criteria: (1) randomized controlled trials (RCTs), prospective or retrospective cohort studies; (2) comparing C-TKA to RA-TKA; (3) enrolling adult patients with TKA; and (4) with follow up at least 3 months. In this review, we considered computer-assisted stereotaxic navigation as part of the RA-TKA category. To minimize bias related to surgical inexperience, studies in which surgeons were within the initial learning curve of robotic-assisted TKA were excluded.
After removing duplicates, two independent reviewers (D.C. and B.C.) screened all titles and abstracts for eligibility. Full-text articles were retrieved for studies that met the inclusion criteria or when relevance was uncertain. Any disagreements during the selection process were resolved by consensus or, if necessary, through consultation with the senior author (F.O.).
2.2 Outcomes of interest
Studies were included only if they reported any of the clinical outcomes of interest. Among these outcomes were operative time, estimated blood loss, tourniquet time, mechanical axis or component alignment accuracy, postoperative complication rates, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Functional score of the Knee Society Score (KSS-FS), and 12-Item Short Form Health Survey (SF-12).
All included studies reported that procedures were performed by experienced orthopaedic surgeons proficient in both robotic-assisted and conventional total knee arthroplasty techniques. The robotic systems utilized across the included studies were OMNIBotics®, Mako™ (Stryker), NAVIO (Smith & Nephew), iAssist® (Zimmer Biomet) and ROSA® (Zimmer Biomet).
2.3 Search strategy and registration
A systematic search of MEDLINE, Scopus, and the Cochrane Library was conducted from database inception to July 2025 using Medical Subject Headings (MeSH) and relevant keywords, including: “total knee arthroplasty,” “robotic assisted,” “conventional,” “body mass index,” “functional outcomes,” and “complication rates.” A comprehensive description of the full search strategy is provided in Supplementary Appendix 1. No language restrictions were applied. The study protocol was prospectively registered in PROSPERO on July 18, under registration number CRD420251107165. Available from: https://www.crd.york.ac.uk/PROSPERO/view/CRD420251107165.
2.4 Quality assessment
Risk of Bias was assessed using the Cochrane Risk of Bias 2.0 (RoB2)13 tool for RCTs and the Risk Of Bias In Non-randomized Studies of Interventions (ROBINS-I)14 tool for cohort studies. Two authors (D.C. and B.C.) independently performed all assessments, with discrepancies resolved through consensus. Publication bias was assessed by funnel plot.
2.5 Data extraction and statistical analysis
Data extraction was independently conducted by two reviewers (D.C. and B.C.) using a standardized data collection form in Microsoft Excel (version 2509). For continuous outcomes, mean differences (MD) with 95 % confidence intervals (CIs) were calculated, with statistical significance defined as p < 0.05. Heterogeneity was evaluated using Cochrane Q test (p < 0.10) and I2 statistic (>50 %) considered indicative of substantial heterogeneity. A random-effects model based on Restricted Maximum Likelihood (REML) estimation was applied. Statistical analyses were conducted using Review Manager version 5.4.15
3 Results
3.1 Study selection and characteristics
A total of 265 records were initially identified through database searches. Of these, 5 studies met the predefined eligibility criteria, comprising 979 patients in total (Fig. 1). 418 patients (42.7 %) underwent RA-TKA. The mean age in the C-TKA group was 68.35 ± 2.59 years, with a mean BMI of 34.05 ± 3.5 kg/m2. Overall study characteristics are summarized in Table 1. The mean operative time was 126.94 ± 52.02 min for the RA-TKA group compared with 114.34 ± 48.43 min for the C-TKA group. The mean follow-up was 11.8 ± 11.16 months. Additionally, 283 participants across both groups had an American Society of Anesthesiologists (ASA) classification ≥3.

| Study | Design | Patients RA-TKA/C-TKA | Robotic system | Implant system RA-TKA/C-TKA (n° patients) | Alignment strategy | Age† RA-TKA/C-TKA (years) | BMI† RA-TKA/C-TKA | Female Gender RA-TKA/C-TKA, N° (%) | Operative Time† (mins) | ASA ≥3 (%) | Follow-up (months) |
| Borazjani 202516 | Retrospective | 146/54 | OMNIBotics® and Mako™ (Stryker) | CR (137), PS (2) and AP (6)/CR (54) | Kinematic | 66.33 ± 7.51/68.93 ± 7.03 | 34.58 ± 3.20/34.77 ± 4.38 | 75 (51.4)/30 (55.6) | NA | 71.7/61.1 | 3 |
| Held 202118 | Retrospective | 111/110 | NAVIO (Smith & Nephew) | PS | Classic | 69/70 | 30.6/30.1 | 74 (67)/72 (66) | 107/123 | 36.4/34.2 | 24 |
| Richardson 202317 | Retrospective | 60/59 | Mako™ (Stryker) | PS | Classic | 63.17 ± 8.59/63.83 ± 7.34 | 39.48 ± 3.80/39.34 ± 3.41 | 47 (78.33)/43 (72.88) | 180 ± 16.34/166 ± 17.62 | 66.7/47.5 | 3 |
| Rivkin 202319 | RCT | 30/30 | iAssist® (Zimmer Biomet) | PS | Classic | 66.9/70.1 | 35.6/34.4 | NA | 77/70 | NA | 24 |
| Schrednitzki 202220 | Retrospective | 71/308 | ROSA® (Zimmer Biomet) | PS | Functional | 68.4 ± 0.9/68.9 ± 0.5 | 31.72 ± 0.3/31.67 ± 0.3 | NA | NA | NA | 5 |
The most frequent complication in both groups was surgical site complications, reported in 10 cases in the RA-TKA group and 19 cases in the C-TKA group. Manipulation under anesthesia (MUA) represented the second most common complication in both groups, with 6 and 8 cases, respectively. Additionally, reoperations were reported in 6 patients in the RA-TKA group.
Comorbidities were reported in both groups. In the C-TKA group, the most frequent condition was hypertension (22 patients), followed by diabetes (16 patients) and smoking (14 patients). Similarly, in the RA-TKA group, hypertension was the most prevalent comorbidity (13.1 %), followed by smoking (7.7 %) and obstructive sleep apnea (6.7 %).
Only one study reported postoperative outcomes using the KOOS JR, which mean was 73.15 ± 13.77 in the RA-TKA group compared with 67.54 ± 13.06 in the C-TKA group, demonstrating a statistically significant difference in favor of RA-TKA (p = 0.01).16 Additionally, another study reported tourniquet time during TKA procedures, showing significantly longer times in the robotic group (93.33 ± 9.87 min) compared with the conventional group (75.53 ± 9.29 min; p < 0.001).17
3.2 Pooled analysis of all studies
In patients who underwent with RA-TKA, operative time was significantly longer compared to those treated with C-TKA (MD 12.14 min; CI 95 % 7.24 to 17.05; p = < 0.001; I2 = 0 %). Postoperative hip-knee-ankle (HKA) alignment (°) demonstrated slightly improved with RA-TKA compared to C-TKA (MD -0.88°; CI 95 % −1.76 to −0.01; p = 0.05; I2 = 10 %). (Fig. 2).
![A: Operative time was found to be significantly longer in RA-TKA compared with C-TKA (p < 0.00001). B: RA-TKA demonstrated a statistically significant advantage in achieving more accurate HKA alignment compared to C-TKA (p = 0.05). CI = confidence interval. SD = standard deviation. REML = Restricted Maximum Likelihood. TKA = total knee arthroplasty. RA-TKA = robotic-assisted TKA. C-TKA = conventional TKA. HKA = hip-knee-ankle. [°] = degrees. [min] = minutes.](/content/220/2026/72/1/img/S0972978X2500474X-gr2.jpg)
With respect to WOMAC scores, no statistically significant differences were found in pain (MD -0.22; 95 % CI, −3.11 to 2.68; p = 0.88; I2 = 32 %), stiffness (MD 0.50; 95 % CI, −1.01 to 2.01; p = 0.52; I2 = 90 %), or function (MD –4.07; 95 % CI, −9.26 to 1.11; p = 0.12; I2 = 16 %). KSS-FS score did not differ significantly between RA-TKA and C-TKA (MD –5.65; 95 % CI, −11.72 to 0.41; p = 0.07; I2 = 0 %) (Fig. 3). Regarding estimated blood loss (EBL), no significant difference was observed between the two surgical techniques (MD 27.53 mL; 95 % CI, −13.38 to 68.45; p = 0.19; I2 = 89 %). Similarly, complication rates did not differ significantly between groups (RR 0.79; 95 % CI, 0.44–1.42; p = 0.43; I2 = 31 %) (Fig. 4).

![A: No significant difference in estimated blood loss was observed between RA-TKA and C-TKA (p = 0.19). B: Complication rates did not differ substantially between the two technique (p = 0.43). CI = confidence interval. SD = standard deviation. REML = Restricted Maximum Likelihood. TKA = total knee arthroplasty. RA-TKA = robotic-assisted TKA. C-TKA = conventional TKA. [ml] = milliliters.](/content/220/2026/72/1/img/S0972978X2500474X-gr4.jpg)
Given the substantial heterogeneity observed, a leave-one-out sensitivity analysis was performed, systematically excluding each study individually to evaluate the robustness of the pooled results. The removal of any single study did not materially affect the overall EBL. However, since this analysis was based on only two studies, the apparent stability of the results likely reflects limited statistical power rather than true robustness. Potential sources of heterogeneity may include differences in variability among robotic platforms, as well as inconsistencies in surgical techniques and perioperative protocols between the two approaches. Although all procedures were performed by experienced surgeons, no sensitivity analyses were conducted to account for potential learning curve effects.
3.3 Quality assessment
The quality of the included randomized study was evaluated using the RoB213 tool, and it was classified as having a low risk of bias. Non-randomized studies were assessed with the ROBINS-I14 tool: one study was rated as low risk, two as moderate risk, and one as serious risk (Figs. 2 and 3, Supplementary Appendix). The funnel plot analysis demonstrated a symmetrical distribution of studies around the pooled effect size (Fig. 4, Supplementary Appendix).
4 Discussion
To the best of our knowledge, this is the first systematic review and meta-analysis specifically addressing two key surgical approaches to TKA in obese patients, with a comprehensive evaluation of operative time, alignment, and functional outcomes. Our findings indicate that RA-TKA is associated with a significantly longer operative time; however, the superior postoperative HKA alignment (<1°) compared with C-TKA is unlikely to be clinically meaningful. It is noteworthy that no statistically significant differences were observed in complication rates, WOMAC and KSS-FS scores, suggesting that patient-reported functional outcomes and complication profiles remain comparable between RA-TKA and C-TKA, despite the procedural differences inherent to each surgical technique. Furthermore, the present analysis revealed no statistically significant differences in EBL, indicating that both surgical approaches demonstrate a comparable intraoperative safety profile with respect to perioperative bleeding.
Our findings are consistent with McCormick et al.21 demonstrating no significant differences in complication rates between RA-TKA and C-TKA. This may be explained by the fact that perioperative complications such as wound healing problems, patellar tendon rupture, prosthetic joint infections, or other surgical site complications are more strongly influenced by patient comorbidities, surgical environment, and postoperative care protocols rather than the surgical technique itself. Although a statistically significant difference in HKA alignment was observed with RA-TKA (MD 0.88°), the magnitude of this difference is not clinically meaningful. This finding may be influenced by factors such as surgeon experience and the limited number of studies included in the analysis. However, prior studies, including that by Banger et al.,22 have further demonstrated the superior precision of robotic-assisted techniques in restoring lower limb alignment after TKA. This advantage is likely attributable to the capacity of RA-TKA to provide three-dimensional preoperative planning and real-time intraoperative feedback, thereby facilitating more accurate bone resections and implant positioning compared to conventional manual instrumentation.
On the other hand, our study did not demonstrate any statistically significant differences in WOMAC and KSS-FS scores between RA-TKA and C-TKA. In contrast, Marchand et al.23 and Khlopas et al.24 conducted in a non-obese population reported significant improvements in pain and functional outcomes, suggesting that obesity may play a critical role in modulating patient-reported outcomes after TKA and could partly explain the discrepancies observed across studies.
We observed a significant difference in operative time, with RA-TKA procedures requiring longer durations compared to C-TKA. This finding is consistent with evidence from systematic reviews conducted in non-obese populations, Onggo et al.25 reported prolonged operative times for RA-TKA (MD = 21.50 min; p = 0.006), while Fozo et al.26 demonstrated a similar trend (MD = 16.85 min; p = 0.0002). A plausible explanation is that robotic-assisted procedures involve additional steps, such as system setup, preoperative imaging integration, intraoperative registration, and calibration of the robotic platform. This is an important consideration, as previous studies have demonstrated that prolonged operative time is associated with an increased risk of prosthetic joint infection, with an odds ratio of 5.11.27
Although it was not possible to perform a cost-effectiveness analysis within the scope of this meta-analysis, Hua et al.28 indicate that robotic-arm assisted TKA has been reported as cost-effective compared with conventional TKA at the accepted willingness-to-pay threshold. Notably, the average additional cost was approximately $747.35, while the gain in quality-adjusted life years (QALYs) was modest at 0.01 over a 10-year time horizon, the overall episode-of-care (EOC) costs for RA-TKA were 1.10 times higher than those for C-TKA (p < 0.001). Fang et al.29 reported that, when extrapolated, if all annual cases (∼4000 procedures) were performed using robotic assistance, the additional financial burden would be equivalent to the cost of approximately 370 conventional TKA procedures.
The learning curve for robotic-assisted TKA varies considerably across systems and institutions, with improvements in operative efficiency and workflow typically observed within the first 8–30 cases; approximately 20 cases are often cited as a pragmatic threshold for proficiency.30,31 Obesity introduces additional technical challenges, such as increased soft-tissue volume and altered joint biomechanics, that heighten the risk of alignment inaccuracies and wound complications. These factors may prolong the learning curve; however, evidence specifically quantifying this effect in obese populations remains scarce.
However, several limitations must be acknowledged. Despite the use of a comprehensive search strategy, the heterogeneity among the included studies, along with the limited number of RCTs and observational studies in this specific patient subgroup, may restrict the generalizability of our findings and contribute to sample size imbalance. An additional limitation was the limited follow-up duration in several studies, potentially insufficient to detect clinically relevant differences in long-term TKA outcomes. Furthermore, not all studies reported standardized outcome measures, and in some cases, the absence of unit specifications or measures of dispersion (such as standard deviations or confidence intervals) hindered the inclusion of certain functional outcomes in the meta-analysis, even after attempts to contact the authors. Another limitation was that, although all studies reported that the surgeries were performed by fellowship-trained orthopaedic surgeons, the years of experience and annual TKA volumes were not standardized, which may limit the reliability of the findings. Including computer-assisted navigation within the RA-TKA group may have introduced heterogeneity, as these systems differ in automation and precision, potentially influencing operative time and alignment outcomes.
This study represents the first systematic review and meta-analyses to directly compare conventional and robotic-assisted TKA specifically in obese patients. A key strength of our work is the relatively large, pooled sample size of 979 patients. In addition, we carefully included a broad spectrum of studies, encompassing different levels of evidence, to ensure a comprehensive synthesis of the available literature. Importantly, our analysis revealed a statistically significant difference in operative time between the two surgical approaches, a finding that may hold substantial implications for guiding future clinical decision-making and surgical practice in orthopaedic surgery. For future research, high-quality studies focusing on this subgroup of patients are warranted, as they represent a growing proportion of the global population and would likely enhance the reliability and validity of future findings.
While RA-TKA demonstrates achieving optimal HKA alignment, its longer operative time may increase the risk of periprosthetic joint infection. Therefore, the choice of surgical approach should be individualized, particularly in obese patients who frequently present with multiple comorbidities. Careful consideration of the surgeon's expertise, the patient's functional demands, and their tolerance for potential complications remains essential in guiding clinical decision-making.
5 Conclusions
In conclusion, while RA-TKA results in longer operative durations, it offers no clinically significant advantage in postoperative HKA alignment compared with conventional TKA, nor does it demonstrate significant differences in other analyzed outcomes. Ultimately, the decision should not be a one-size-fits-all approach, but rather a personalized strategy that weighs accuracy, surgical efficiency, and cost-effectiveness. These findings set the stage for future high-quality trials to determine whether the precision of robotics can truly translate into long-term functional and survival benefits in this challenging patient population.
Guardian/patient's consent
Not applicable.
Data availability statement
All data relevant to this study are included in the article and its supplementary files.
Ethics statement
This study is a systematic review and meta-analysis of previously published data and did not involve direct participation of human subjects or access to identifiable personal information. Therefore, approval from an Institutional Review Board (IRB) or Ethics Committee was not required.
Disclosure of interest
The authors, their immediate family, and any research foundation with which they are affiliated did not receive any financial payments or other benefits from any commercial entity related to the subject of this article.
Credit author statement
○ Diego Calderon, MD: conceptualization, methodology, software, validation, formal analysis, investigation, resources, data curation, writing- original draft, writing-review and editing, supervision, project administration.
○ Betty Chumacero, MD: conceptualization, methodology, software, validation, formal analysis, investigation, writing- original draft, writing-review and editing.
○ Francis Ordinola, MD: investigation, resources, data curation, writing-review and editing, supervision.
Funding statement
This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors.
References
- 1999: Geneva S, Organization WH. Obesity : Preventing and Managing the Global Epidemic : Report of a WHO Consultation. 2000
- [Google Scholar]
- Does weight loss reduce the incidence of total knee and hip replacement for osteoarthritis?—A prospective cohort study among middle-aged and older adults with overweight or obesity. Int J Obes. 2021;45:1696-1704.
- [Google Scholar]
- A prospective, longitudinal study of the influence of obesity on total knee arthroplasty revision rate: results from the Australian orthopaedic association national joint replacement registry. J Bone Joint Surg Am. 2022;104:1386-1392.
- [Google Scholar]
- Rates of total joint replacement in the United States: future projections to 2020-2040 using the national inpatient sample. J Rheumatol. 2019;46:1134-1140.
- [Google Scholar]
- Obesity, osteoporosis and bone metabolism. J Musculoskelet Neuronal Interact. 2020;20:372-381.
- [Google Scholar]
- Robot-assisted total knee arthroplasty improves mechanical alignment and accuracy of component positioning compared to the conventional technique. J Exp Orthop. 2022;9:108.
- [Google Scholar]
- Greater risk of periprosthetic joint infection associated with prolonged operative time in primary total knee arthroplasty: meta-analysis of 427,361 patients. J Clin Med. 2024;13:3046.
- [Google Scholar]
- Risk factors for surgical-site infection following primary total knee arthroplasty. Infect Control Hosp Epidemiol. 2004;25:477-480.
- [Google Scholar]
- Cochrane Handbook for Systematic Reviews of Interventions 2025
- [Google Scholar]
- The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. Br Med J. 2021;372:n71.
- [Google Scholar]
- RoB 2: a revised tool for assessing risk of bias in randomised trials. Br Med J. 2019;366
- [Google Scholar]
- ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions. Br Med J. 2016;355
- [Google Scholar]
- Robotic-assisted total knee arthroplasty leads to early functional improvement in patient-reported outcome among obese patients: a retrospective cross-sectional study. Adv Orthopaedics. 2025;1:1-9.
- [Google Scholar]
- Robotic-assisted total knee arthroplasty in Obese patients. Arthroplast Today. 2024;26
- [Google Scholar]
- Imageless robotic-assisted total knee arthroplasty leads to similar 24-month WOMAC scores as compared to conventional total knee arthroplasty: a retrospective cohort study. Knee Surg Sports Traumatol Arthrosc. 2022;30:1795.
- [Google Scholar]
- Total knee arthroplasty using a computerized assisted stereotaxic navigation system with bluetooth communication in obese patients - a randomized controlled study. Comput Assisted Surg. 2023;28
- [Google Scholar]
- Imageless robotic-assisted total knee arthroplasty is accurate in vivo: a retrospective study to measure the postoperative bone resection and alignment. Arch Orthop Trauma Surg. 2023;143:3471-3479.
- [Google Scholar]
- Robotic-assisted technology does not influence functional outcomes among obese and morbidly obese total knee arthroplasty patients. J Exp Orthop. 2023;10
- [Google Scholar]
- Robotic arm-assisted bi-unicompartmental knee arthroplasty maintains natural knee joint anatomy compared with total knee arthroplasty: a prospective randomized controlled trial. Bone Joint Lett J. 2020;102-B:1511-1518.
- [Google Scholar]
- One-year patient outcomes for robotic-arm-assisted versus manual total knee arthroplasty. J Knee Surg. 2019;32:1063-1068.
- [Google Scholar]
- Patient-Reported functional and satisfaction outcomes after robotic-arm-assisted total knee arthroplasty: early results of a prospective multicenter investigation. J Knee Surg. 2019;33:685-690.
- [Google Scholar]
- Robotic-assisted total knee arthroplasty is comparable to conventional total knee arthroplasty: a meta-analysis and systematic review. Arch Orthop Trauma Surg. 2020;140:1533-1549.
- [Google Scholar]
- A systematic review and meta-analysis of conventional versus robotic-assisted total knee arthroplasty. Cureus. 2023;15
- [Google Scholar]
- Risk factors for periprosthetic joint infection after total knee arthroplasty. Arch Orthop Trauma Surg. 2020;140:239-245.
- [Google Scholar]
- Cost-effectiveness analysis of robotic-arm assisted total knee arthroplasty. PLoS One. 2022;17
- [Google Scholar]
- Total knee arthroplasty hospital costs by time-driven activity-based costing: robotic vs conventional. Arthroplasty Today. 2022;13:43-47.
- [Google Scholar]
- Operative time learning curve for an image-free robotic arm assisted total knee arthroplasty: a cumulative sum analysis. Arthroplast Today. 2024;31
- [Google Scholar]
- Learning curve analysis of robotic-assisted total knee arthroplasty with a Chinese surgical system. J Orthop Surg Res. 2023;18:900.
- [Google Scholar]

