Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical research study
Current Issue
Editorial Board
Literature Review
Narrative review
Original Article
Research Article
Review Article
Short Report
Surgical techniques
Systematic Review and Meta-Analysis
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical research study
Current Issue
Editorial Board
Literature Review
Narrative review
Original Article
Research Article
Review Article
Short Report
Surgical techniques
Systematic Review and Meta-Analysis
View/Download PDF
66 (); 287-292
doi:
10.1016/j.jor.2025.06.019

Translate:

Robotic-assisted “physiological alignment” TKA with a 3-degree varus inclination does not affect gait ability, regardless of pre-arthritic CPAK classification matching

Author affiliations
Ichinomiya Onsen Hospital, Department of Rehabilitation, Japan
Ichinomiya Onsen Hospital, Adult Reconstruction Center, Japan
Article History
Corresponding author(s)

⁎Corresponding author: Takao Kaneko. takaokaneko1208@yahoo.co.jp

Article tools · PDF & citations

Abstract

Abstract

Traditionally, the hip-knee-ankle (HKA) angle has been used as an indicator of lower limb mechanical alignment to predict postoperative outcomes in total knee arthroplasty (TKA). However, patients with knee osteoarthritis exhibit considerable individual variation in coronal plane alignment of the lower limb. The Coronal Plane Alignment of the Knee (CPAK) classification was introduced as a novel method to reflect these individual alignment characteristics. Nevertheless, it remains inconclusive whether aligning the lower limb to the patient's native CPAK phenotype before and after TKA leads to improved outcomes.

The purpose of this study is to investigate the impact of postoperative CPAK phenotypes and the changes from pre-to postoperative states on gait in robotic-assisted (RA) bi-cruciate stabilized (BCS) TKA using an asymmetric prosthesis aimed at achieving functional alignment (FA).

and Setting: This retrospective, single-surgeon, consecutive cohort study included 46 patients who underwent RA-BCS TKA.

Pre- and postoperative CPAK classifications were compared, and changes in the arithmetic hip-knee-ankle angle (aHKA), joint line obliquity (JLO), and gait analysis scores were evaluated both preoperatively and one year postoperatively.

No significant differences were observed between the two groups in preoperative or postoperative walking ability, or in the postoperative changes in gait parameters.

RA-BCS TKA using physiological alignment and an asymmetric prosthesis with a built-in 3° varus inclination demonstrated no significant differences in walking ability, regardless of the prearthritic CPAK classification.

Level Ⅲ

Keywords

  • Robotic assisted bi-cruciate stabilized total knee arthroplasty
  • Coronal plane alignment of the knee
  • Arithmetic hip knee ankle angle
  • Joint line obliquity
  • Gait analysis
Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

Total knee arthroplasty (TKA) is a common and cost-effective surgical treatment for knee osteoarthritis, known to reduce pain and improve quality of life.1–3 However, according to patient-reported outcome measures (PROMs), up to 19 % of patients remain dissatisfied with the results of primary TKA.4 Postoperative dissatisfaction is a well-documented phenomenon.5

Lustig advocates for personalized alignment to restore knee kinematics and enhance functional outcomes following TKA.6 Therefore, precise osteotomy and implant placement are crucial in TKA surgery. At our institution, we utilize the semiautonomous CORI robotic system. This imageless, handheld robotic platform enables real-time planning and gap assessment, optimized alignment and balance, and robotic-assisted bone resection, all under the surgeon's control, allowing for a highly individualized approach.

In recent years, robot-assisted TKA has been increasingly adopted and has demonstrated effectiveness in achieving accurate osteotomy and implant positioning, as well as in improving PROMs.7–9

Traditionally, the hip-knee-ankle (HKA) angle has been used as an indicator of lower limb mechanical alignment to predict postoperative outcomes in TKA. However, patients with knee osteoarthritis exhibit considerable individual variation in lower limb coronal plane alignment, including femoral and tibial alignment differences.10 Some studies also report that changes in coronal alignment before and after surgery can negatively impact PROMs.11

We believe that conventional approaches aiming for uniform alignment reconstruction may not be suitable for all cases.

In 2021, the Coronal Plane Alignment of the Knee (CPAK) classification was proposed by Samuel J. MacDessi as a novel method for categorizing individual alignment characteristics of the lower extremity.12 The CPAK classification defines nine phenotypes of coronal alignment based on arithmetic hip-knee-ankle angle (aHKA) and joint line obliquity (JLO). This classification has the potential to facilitate more individualized strategies for total knee arthroplasty (TKA). However, it remains inconclusive whether restoring lower limb alignment to a patient's native CPAK phenotype before and after surgery improves outcomes.

Gait analysis, on the other hand, is a valuable tool that provides dynamic measures of joint function and is commonly used to assess postoperative mobility and quality of life (QOL). In recent years, the widespread availability of portable gait analysis devices has enabled easier data collection and contributed to the accumulation of clinical evidence.

To date, no studies have examined the relationship between changes in CPAK classification before and after surgery and their impact on gait. Clarifying this relationship would be highly significant in advancing personalized approaches to TKA.

The purpose of this study is to investigate the impact of postoperative CPAK phenotypes and the changes from pre-to postoperative states on gait in robotic-assisted (RA) bi-cruciate stabilized (BCS) TKA using an asymmetric prosthesis aimed at achieving functional alignment (FA).

2

2 Materials and methods

2.1

2.1 Participants and study subjects

Between 2022 and 2024, a prospective cohort study was conducted involving consecutive patients who underwent total knee arthroplasty (TKA) performed by a single surgeon (T.K.). The study included 46 knees from 46 patients (14 males and 32 females) who underwent bicruciate-stabilized TKA (Journey II BCS, Smith & Nephew, Memphis, TN, USA) for the treatment of medial-type knee osteoarthritis (OA).

The mean age, height, and weight at the time of surgery were 77.4 ± 6.3 years, 155.1 ± 8.6 cm, and 61.9 ± 10.8 kg, respectively (Table 1).

Table 1 Pre-operative demographic data.
Parameter Mean (SD: range)
Age (year) 77.4 (6.3: 65–91)
Male; female 14; 32
Hight (cm) 155.1 (8.6: 144–180)
Weight (kg) 61.9 (10.8: 43∼94.6)
BMI (kg/m2) 25.7 (3.9: 18.6–29.8)
Extension angle (°) −14.5 (6.5: 25∼ −3)
Flexion angle (°) 113.7 (9.2: 100–134)

Exclusion criteria included valgus knee deformity, rheumatoid arthritis, secondary osteoarthritis, severe extra-articular deformities, a history of high tibial osteotomy, knee joint infection, and any comorbid conditions affecting postoperative recovery or gait—such as pathology involving the contralateral knee, spine, hip, or ankle.

2.2

2.2 Surgical procedure and rehabilitation

Robotic-assisted total knee arthroplasty (RA-TKA) was performed using the measured resection technique. A tourniquet was inflated to 300 mmHg at the start of the procedure, followed by a subvastus arthrotomy. Distal femoral osteotomy was performed using an intramedullary resection guide at a valgus angle determined by preoperative 3D CT planning. Rotational alignment of the femur was adjusted according to the surgical epicondylar axis. The anterior referencing technique was used for the posterior femoral cut. Femoral component size was selected based on the anteroposterior length of the femur, independent of the flexion gap. If the measurement fell between sizes, the smaller femoral component was chosen.

For the proximal tibial osteotomy, an extramedullary resection guide was used. The osteotomy angle was set perpendicular to the mechanical axis to reproduce the preoperative posterior tibial slope, based on preoperative 3D CT planning in both the coronal and sagittal planes. Tibial rotational alignment was defined by the anteroposterior axis between the medial intercondylar tubercle and the medial border of the patellar tendon. In both groups, the patella was resurfaced.

Weight-bearing was not restricted, and patients were allowed to ambulate with or without assistive devices beginning on the first postoperative day.

2.3

2.3 Radiographic measurements

All patients underwent digital long leg radiographs (LLRs) according to the method described by Paley and Pfeil.13 Each knee was classified using the CPAK system, as proposed by Samuel J. MacDessi, both preoperatively and postoperatively.12 A single experienced observer, who was not involved in the surgical procedures, measured the lateral distal femoral angle (LDFA) and the medial proximal tibial angle (MPTA) on these radiographs.

The LDFA was defined as the lateral angle between the femoral mechanical axis and the distal femoral joint line. The MPTA was defined as the medial angle between the tibial mechanical axis and the proximal tibial joint line.

In this study, a tibial implant with a built-in 3-degree internal tilt was used; therefore, postoperative MPTA values were adjusted by subtracting 3° to account for this tilt.

The arithmetic hip-knee-ankle (aHKA) angle was calculated as MPTA - LDFA, and joint line obliquity (JLO) was calculated as MPTA + LDFA.

Patients whose CPAK classification remained unchanged before and after surgery were designated as the Matching group (M group), while those whose classification changed were designated as the Change group (C group).

2.4

2.4 Gait analysis

A 10-m walk test was conducted preoperatively and one year postoperatively. The measurement setup consisted of a 3-m acceleration runway, a 10-m walkway, and a 3-m deceleration zone, for a total length of 16 m. Subjects began the test from a static standing position at the start of the runway and were verbally instructed to “walk as fast as you normally walk” before receiving a signal to start walking.

Gait analysis data were collected using a triaxial accelerometer (AYUMIEYE; Waseda Elderly Health, Inc., Association). The AYUMIEYE device instantly evaluates gait function based on acceleration data during walking, utilizing an embedded gait cycle extraction algorithm within an iOS application (Fig. 1).14 The program predicts the duration of subsequent gait cycles based on foot contact data identified through a segmentation algorithm. In accelerometer-based gait analysis, gait motion is treated as a periodic movement of the body's center of gravity (COG). Rhythmic changes in the COG are measured using the accelerometer, allowing for objective assessment of gait abnormalities.15–17

(a) AYUMIEYE (Waseda Elderly Health Association): triaxial accelerometer with an iOS application (b) Scene of gait measurement with AYUMI EYE. 3-axis acceleration sensor is attached to the subject's waist with a dedicated strap band at the height of the subject's third lumbar vertebra.
Fig. 1 (a) AYUMIEYE (Waseda Elderly Health Association): triaxial accelerometer with an iOS application (b) Scene of gait measurement with AYUMI EYE. 3-axis acceleration sensor is attached to the subject's waist with a dedicated strap band at the height of the subject's third lumbar vertebra.

The AYUMIEYE device was secured using a specialized belt positioned at the level of the subject's third lumbar vertebra (Fig. 1). The iOS application (Apple Inc., Cupertino, CA, USA) connected to the device recorded gait parameters including walking speed, stride length, root mean square (RMS), and gait cycle variability.

RMS (1/m) reflects the degree of lateral sway during walking; lower values indicate better balance. RMS was calculated by dividing lateral acceleration by the square of the walking speed. Gait cycle variability was defined as the standard deviation of the time required to complete one gait cycle (in seconds). In this device, one gait cycle is defined as the time from left heel contact to right heel contact and back to left heel contact. Lower variability indicates a more stable gait rhythm.

Walking speed was measured in both directions, and the faster value was used for analysis.

2.5

2.5 Statistical analysis

All statistical analyses were performed using IBM SPSS Statistics for Windows, Version 27.0 (IBM Corp., Armonk, NY, USA). Quantitative variables were expressed as mean ± standard deviation, and comparisons between the two groups were conducted using an unpaired t-test. A p-value of <0.05 (two-tailed) was considered statistically significant.

A priori statistical power analysis was conducted using G∗Power 3.1 (Heinrich Heine University Düsseldorf). Based on an effect size of 0.8, a significance level of 0.05, and a power of 0.80, the required sample size was calculated to be 21 participants per group. In this study, 23 participants per group were included, indicating that the sample size was sufficient to achieve adequate statistical power.

3

3 Results

There were no significant differences in baseline characteristics between Group M (n = 23) and Group C (n = 23) (Table 2).

Table 2 Pre-operative demographic data.
Parameters Matching group (n = 23) Change group (n = 23) p value
Age (year) 77.17 (6.38: 65–88) 77.68 (6.17: 65–91) n.s
Male; female 7:16 7:16 n.s
Hight (cm) 152.73 (7.67: 140–170) 157.67 (9.51:141–180) n.s
Weight (kg) 60.96 (8.7: 45∼81.2) 63.06 (12.55: 43∼94.6) n.s
BMI (kg/m2) 26.11 (2.96: 19.15–32.84) 25.35 (4.59: 19.64–36.36) n.s
Extension angle (°) −14 (6.63: 25∼-5) −15.27 (6.17: 25∼-3) n.s
Flexion angle (°) 111.87 (8.17:100–130) 116.09 (9.99: 105–134) n.s

Pre- and postoperative phenotypes distribution in Coronal Plane Alignment of the Knee Classification (CPAK) are shown in Table 3. Figs. 2 and 3 show the distribution and percentage of phenotypes before and after surgery in the matching and change groups, respectively. No significant differences were also observed in preoperative coronal alignment of the lower extremity (Table 4). Postoperative coronal alignment parameters are shown in Table 5, where significant differences were found in MPTA (p = 0.01), aHKA (p = 0.04), and JLO (p = 0.03).

Table 3 Pre- and postoperative phenotypes distribution in Coronal Plane Alignment of the Knee Classification (CPAK).
CPAK Phenotype Pre-operative (%) Post-operative (%)
I Varus + Apex distal 34 knee (73.9 %) 26 knee (56.5 %)
II Neutral + Apex distal 6 knee (13 %) 6 knee (13 %)
Ⅲ Valgus + Apex distal 1 knee (2.2 %) 0
IV Varus + Apex neutral 4 knee (8.7 %) 13 knee (28.3 %)
V Neutral + Apex neutral 1 knee (2.2 %) 1 knee (2.2 %)
Pre- and postoperative CPAK classification distribution for the Matching group CPAK, Coronal Plane Alignment of the Knee; aHKA, arithmetic hip-knee- ankle angle; JLO, joint line obliquity; LDFA, lateral distal femoral angle; MPTA, medial proximal tibial angle.
Fig. 2 Pre- and postoperative CPAK classification distribution for the Matching group CPAK, Coronal Plane Alignment of the Knee; aHKA, arithmetic hip-knee- ankle angle; JLO, joint line obliquity; LDFA, lateral distal femoral angle; MPTA, medial proximal tibial angle.
Pre- and postoperative CPAK classification distribution for the Change group CPAK, Coronal Plane Alignment of the Knee; aHKA, arithmetic hip-knee- ankle angle; JLO, joint line obliquity; LDFA, lateral distal femoral angle; MPTA, medial proximal tibial angle.
Fig. 3 Pre- and postoperative CPAK classification distribution for the Change group CPAK, Coronal Plane Alignment of the Knee; aHKA, arithmetic hip-knee- ankle angle; JLO, joint line obliquity; LDFA, lateral distal femoral angle; MPTA, medial proximal tibial angle.
Table 4 Pre-operative alignment.
Parameters Matching group (n = 23) Change group (n = 23) p value
LDFA 90.31 (2.61: 85.9–95.2) 89.09 (3.46: 82.6–95) n.s
MPTA 81.81 (2.36: 77.1–85.5) 83.38 (3.2: 77.1–91.6) n.s
aHKA −8.5 (3.85: 17.1∼-2.2) −5.7 (5.54: 17.9–9) n.s
JLO 172.1 (3.16: 166.4–179.3) 172.5 (3.7:164.7–180) n.s
Table 5 Post-operative alignment.
Parameters Matching group (n = 23) Change group (n = 23) p value
LDFA 90.2 (1.66: 85.4–93.7) 90.35 (3.12: 85.6–96.4) n.s
MPTA 84.13 (2.12:7 8.2–87.9) 85.7 (1.36: 83∼88.2) 0.01∗∗
aHKA −6.07 (2.77: 14.7∼-2.2) −4.13 (3.19: 10.4–2) 0.04∗
JLO 174.3 (2.63:165.9–179.8) 176.6 (3.88:169.5–182.7) 0.03∗

There were no significant differences in walking ability between Group M and Group C either preoperatively (Table 6) or postoperatively (Table 7). Table 8 shows the percentage change in walking parameters from before to after surgery. In both groups, walking speed and stride length increased, while RMS decreased. Gait cycle variability increased in Group M but decreased in Group C. However, no significant differences were observed between the two groups in the rate of change for any of the gait parameters.

Table 6 Pre-operative 10-m walk test.
Parameters Matching group (n = 23) Change group (n = 23) p value
Velocity (m/s) 0.86 (0.2: 0.45–1.29) 0.91 (0.23: 0.52–1.33) n.s
Stride length (cm) 51.33 (7.13: 38.7–66.6) 52.21 (10.15: 36.5–71.4) n.s
RMS (1/m) 2.91 (1.39: 1.33–6.09) 2.69 (1.56:1.05–6.5) n.s
Gait cycle variability (s) 0.04 (0.02: 0.02–0.11) 0.04 (0.02: 0.02–0.11) n.s
Table 7 Post-operative 10-m walk test.
Parameters Matching group (n = 23) Change group (n = 23) p value
Velocity (m/s) 1.05 (0.2: 0.69–1.38) 1.05 (0.21: 0.58–1.58) n.s
Stride length (cm) 58.23 (7.62: 44.2–70.9) 58.57 (8.71: 39.6–74.2) n.s
RMS (1/m) 1.86 (0.55: 1.25–3.25) 1.91 (0.91: 1.02–5.09) n.s
Gait cycle variability (s) 0.03 (0.02: 0.01–0.08) 0.03 (0.02: 0.01–0.07) n.s
Table 8 Percentage change in gait parameters before and after surgery.
Parameters Matching group (n = 23)Mean (SD: range) Change group (n = 23)Mean (SD: range) p value
Velocity (%) 26.82 (26.78: 9.3∼86.15) 20.59 (29.08: 11.93–101.67) n.s
Stride length (%) 14.49 (15.27: 10.52–48.72) 13.87 (14.45: 5.88∼44.63) n.s
RMS (%) −28.69 (21.83: 65.27–14.4) −20.47 (27.94: 65.43–40.45) n.s
Gait cycle variability (%) 3.36 (66.32: 66.67–211.76) −12.74 (51.02: 58.14–175) n.s
4

4 Discussion

Notably, alterations in CPAK classification before and after surgery had no impact on postoperative walking ability. In this study, gait performance was assessed using a 10-m walk test in two groups: Group M (no change in CPAK classification) and Group C (change in classification). At one year postoperatively, no significant differences were found between the groups in either gait performance or the rate of functional improvement.

We perform total knee arthroplasty (TKA) using robot-assisted techniques. Rather than uniformly applying mechanical alignment (MA), our approach aims to restore each patient's natural physiological alignment—whether varus or valgus—and the anatomical shape of the knee joint.18 In this study, robot-assisted (RA) technology was used to quantitatively assess and reproducibly restore ligament laxity for each patient, while determining the extent of osteotomy and implant placement based on preoperative mechanical alignment (MA) planning.

According to McClelland et al., gait analysis after TKA has revealed abnormalities in knee flexion and extension moments, as well as alterations in muscle activity patterns.19 These abnormalities may be attributed to soft tissue imbalance, which can negatively affect gait patterns. In the present study, the fact that walking ability was not influenced by changes—or lack thereof—in coronal plane alignment before and after surgery is likely due to the achievement of physiological alignment, in which soft tissue balance was appropriately optimized.

This study also included cases using the Journey II BCS implant, which features a 3-degree internal inclination of the articulating surface. This design facilitates the recreation of a natural joint line and, unlike symmetric prostheses, often results in a higher CPAK classification type.

Inappropriate inclination of the articular surface can negatively affect walking ability. Gait analysis following TKA using the mechanical alignment method has shown that the tibial component tends to tilt outward under load, with the articular surface inclined approximately 5° relative to the ground. Therefore, implants designed with internal inclination in the articulating surface are thought to better align the joint surface parallel to the ground during weight-bearing.20

We believe that restoring joint surfaces to more closely match the patient's preoperative joint geometry—regardless of changes in CPAK classification—helped achieve near-normal kinematics and contributed to maintaining or improving walking ability.

It has been reported that the muscle activity of the knee flexors and extensors three months after surgery with the Journey II TKA is equivalent to physiological timing.21 In addition, the anterior positioning of the tibial component relative to the femur may be effective in restoring quadriceps muscle strength, which could have contributed to the improvement in walking ability after surgery.

TKA improves static alignment parameters; however, it has been reported that static alignment does not necessarily influence postoperative walking ability.22 The CPAK classification is a static assessment and may not accurately reflect dynamic function. In this study, gait was evaluated one year after surgery, and it is possible that changes in static coronal alignment may not correspond to alterations in dynamic gait characteristics.

We consider the CPAK classification to be a valuable tool for capturing individual variations in lower limb alignment. However, to better correlate it with dynamic function, a comprehensive approach incorporating evaluations in the sagittal and axial (horizontal) planes may be more effective.

Even if the CPAK classification changes after surgery, gait may be maintained through compensatory mechanisms involving the hip joint, ankle joint, and trunk. It has been reported that movement patterns adapted to chronic deformity may persist for a certain period postoperatively, and the effects of alignment correction may take time to manifest.

In a previous study, we compared gait between BCS-TKA and BCR-TKA,23 and found that gait function recovery was temporarily delayed in BCS-TKA, which compensates for ligament function, for approximately six weeks postoperatively. This delay was attributed to the time required for patients to adapt to the joint damping mechanism, in contrast to BCR-TKA, which preserves the native ligaments.

In the present study, gait analysis was performed one year after surgery. Although gait parameters improved compared to the preoperative state, it remains unclear whether compensatory mechanisms in regions other than the knee—such as the hip, ankle, or trunk—were contributing to this improvement, or whether a new gait pattern had been acquired following surgery.

5

5 Limitations of the study

Several limitations of this study should be acknowledged.

First, the gait parameters used may have been insufficient to fully detect the effects of changes in CPAK classification. As previously noted, there is evidence suggesting a lack of correlation between static alignment and postoperative gait function. Therefore, it may be necessary to evaluate not only walking ability as an outcome but also joint kinematics and kinetics during gait.

Second, limitations in the study design—such as the small sample size and the fixed postoperative evaluation period—may have influenced the results.

These findings indicate that there are limitations in evaluating dynamic knee joint function using CPAK classification alone. Future research should incorporate more comprehensive functional assessment methods and include long-term postoperative evaluation in a larger cohort.

6

6 Conclusion

RA-BCS TKA using physiological alignment and an asymmetric prosthesis with a built-in 3° varus inclination demonstrated no significant differences in walking ability, regardless of the prearthritic CPAK classification.

CRediT authorship contribution statement

Kazuki Amemiya: Wrote and edited the paper. Takao Kaneko: Conception of the study, Researched the ideas. Kosuke Shiga: Analyzed the data. Shogo Horiuchi: Analyzed the data. Masaru Omata: Analyzed the data.

Ethical approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of relevant institutional and national research committees and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. The study was approved by the Institutional Review Board of Ichinomiya Onsen Hospital Adult Reconstruction Center (21013).

Ethical review committee statement

The hospital ethics committee approved the study protocol, and patients provided informed consent for participation in the study. Ethical approval All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committees and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. Institutional Review Board approval for the study was provided by Ichinomiya Onsen Hospital, Adult Reconstruction Center (21013).

Funding

No external source of funding was used.

References

  1. , , , . Cost-effectiveness of total knee arthroplasty in the United States. Arch Intern Med. 2009 Jun 22;169(12):1113-1121.
    [Google Scholar]
  2. , , , . KAT group A randomized controlled trial of the clinical effectiveness and cost-effectiveness of different knee prostheses: the Knee Arthroplasty Trial (KAT) Health Technol Assess. 2014 Mar;18(19):1-235.
    [Google Scholar]
  3. , , , . Knee replacement for osteoarthritis. Maturitas. 2013 Jun;75(2):131-136.
    [Google Scholar]
  4. , , , . Bicruciate retaining arthroplasty. Surg Technol Int. 2012;22:236-242.
    [Google Scholar]
  5. , , , . Patient dissatisfaction following total knee replacement: a growing concern? Bone Joint Lett J. 2014 Nov;96-B(11 Supple A):96-100.
    [Google Scholar]
  6. , , , , , , . Personalized alignment in total knee arthroplasty: current concepts. SICOT J. 2021;7:19.
    [Google Scholar]
  7. , , , , . Coronal alignment classes after robotic-assisted total knee arthroplasty are not associated with variation in patient-reported outcome measurements: a single-center cohort study. Knee. 2023 Mar;41:274-282.
    [Google Scholar]
  8. , , , , . Clinical and radiological outcomes in robotic-assisted total knee arthroplasty: a systematic review and meta-analysis. J Arthroplast. 2020 Nov;35(11):3393-3409.
    [Google Scholar]
  9. , , , , , , . Clinical outcomes in TKA are enhanced by both robotic assistance and patient specific alignment: a comparative trial in 120 patients. Arch Orthop Trauma Surg. 2023 Jun;143(6):3391-3399.
    [Google Scholar]
  10. , , , , , . Highly variable coronal tibial and femoral alignment in osteoarthritic knees: a systematic review. Knee Surg Sports Traumatol Arthrosc. 2019 May;27(5):1368-1377.
    [Google Scholar]
  11. , , , et al . Pre- and postoperative coronal plane alignment of the knee classification and its impact on clinical outcomes in total knee arthroplasty. Bone Joint Lett J. 2024 Oct 1;106-B(10):1059-1066.
    [Google Scholar]
  12. , , , , , . Coronal plane alignment of the knee (CPAK) classification.A new system for describing knee phenotypes. Bone Joint Lett J. 2021 Feb 1;103-B(2):329-337.
    [Google Scholar]
  13. , , . Principles of deformity correction around the knee. Orthopä. 2000;29(1):18-38.
    [Google Scholar]
  14. , , . Accelerometry:A technique for quantifying movement patterns during walking. Gait Posture. 2008;28:11-15.
    [Google Scholar]
  15. , , , et al . Association between trunk acceleration during walking and clinically assessed balance in patients with stroke. NeuroRehabilitation. 2017;41:783-790.
    [Google Scholar]
  16. , , . Comparison of gait analysis between a triaxial accelerometer-based device and an optical motion capture system. Preprints 2020
    [Google Scholar]
  17. , , , . Variability of walking and other daily activities in patients with total knee replacement. Gait Posture. 2009;30(3):288-295.
    [Google Scholar]
  18. , , , et al . Preoperative tibial mechanical axis orientation and articular surface design influence on the coronal joint line orientation relative to the ground during gait after total knee arthroplasties. Knee Surg Sports Traumatol Arthrosc. 2018 Nov;26(11):3368-3376.
    [Google Scholar]
  19. , , , , , , . Pre-operative and post-operative kinematic analysis in total knee arthroplasty. A pilot study. Acta Biomed. 2019 Dec 5;90(12-S):91-97.
    [Google Scholar]
  20. , , , , , . Is static alignment a good predictor of dynamic alignment after total knee arthroplasty? Healthcare (Basel). 2022 Feb 23;10(3):418.
    [Google Scholar]
  21. , , , et al . Anatomical bi-cruciate retaining TKA improves gait ability earlier than bi-cruciate stabilized TKA based on triaxial accelerometery data: a prospective cohort study. Asia Pac J Sports Med Arthrosc Rehabil Technol. 2021 May;31(25):35-41.
    [Google Scholar]