Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical research study
Current Issue
Editorial Board
Literature Review
Narrative review
Original Article
Research Article
Review Article
Short Report
Surgical techniques
Systematic Review and Meta-Analysis
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical research study
Current Issue
Editorial Board
Literature Review
Narrative review
Original Article
Research Article
Review Article
Short Report
Surgical techniques
Systematic Review and Meta-Analysis
View/Download PDF
Original Article
12 (); S62-S64
doi:
10.1016/j.jor.2014.06.015

Translate:

Recurrent atraumatic anterior hip dislocation: Treated by dual mobility system

Author affiliations
Department of Orthopaedics, Sir Charles Gairdner Hospital, Hospital Avenue, Nedlands 6009, Australia
Article History
Corresponding author(s)

∗Corresponding author: Jie X. Xu. jxxu01@gmail.com

Article tools · PDF & citations

Abstract

Abstract

To highlight a case of recurrent atraumatic anterior hip dislocation management using a dual mobility prothesis.

The stability of the patient's hip was assessed using X-ray and MRI scans. Upon the third spontaneous anterior dislocation it was decided with the patient's consent to undergo a total hip replacement. A piriformis sparing anterior approach was use with the insertion of a dual mobility bearing. This consisted of an uncemented porous titanium cup articulating with a 28 mm head in a 42 mm mobile polyethylene liner.

Mobilising pain free at 6 weeks post operation with no further dislocations at 6 months follow up.

Dual mobility hip replacements was used successfully in our patient with recurrent atraumatic anterior hip dislocation.

Keywords

  • Atraumatic anterior hip dislocation
  • Cerebellar ataxia
  • Osteoarthritis
Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.

Conflict of interest

All authors have none to declare.

References

  1. , . The long-term results of low-friction arthroplasty of the hip performed as a primary intervention. J Bone Jt Surg Br Vol. 1972;54:61-76.
    [Google Scholar]
  2. , , , . Biomechanical concept and clinical outcome of dual mobility cups. Int Orthop. 2012;36:2411-2418.
    [Google Scholar]
  3. , , . Replacement of arthritic hips by the McKee-Farrar prosthesis. J Bone Jt Surg Br Vol. 1966;48:245-259.
    [Google Scholar]
  4. , , , , , , . Recurrence of dislocation following total hip arthroplasty revision using dual mobility cups was rare in 180 hips followed over 7 years. HSS J Musculoskelet J Hosp Spec Surg. 2012;8:251-256.
    [Google Scholar]

In this article

Article statistics


Fulltext Views
1,001

PDF downloads
336

Downloads

View/Download PDF
Download Citations
BibTeX
RIS
Show Sections