Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical research study
Current Issue
Editorial Board
Literature Review
Narrative review
Original Article
Research Article
Review Article
Short Report
Surgical techniques
Systematic Review and Meta-Analysis
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical research study
Current Issue
Editorial Board
Literature Review
Narrative review
Original Article
Research Article
Review Article
Short Report
Surgical techniques
Systematic Review and Meta-Analysis
View/Download PDF
70 (); 48-53
doi:
10.1016/j.jor.2025.03.041

Translate:

High variability in pelvic orientation in the lateral decubitus position negatively affects acetabular component placement

Author affiliations
Department of Orthopaedic Surgery, Montefiore Medical Center, 1250 Waters Place, Tower 1, Bronx, NY, 10461, United States
Department of Orthopaedic Surgery, NYU Langone, 333 East 38th Street, New York, NY, 10016, United States
Article History
Corresponding author(s)

⁎Corresponding author: Xiuyi A. Yang. Xayang@montefiore.org

Article tools · PDF & citations

Abstract

Abstract

Determine factors that impart increased risk of acetabular component malposition in the lateral decubitus position.

A retrospective review of 813 X-rays from posterior THA procedures at a single institution. Pelvic tilt and rotation were measured on preoperative standing AP-pelvis and intraoperative cross-table x-rays. Proper intraoperative pelvic orientation (PPO) was defined as vertical tilt and axial rotation within ± 15° of the preoperative standing pelvis orientation. Acetabular abduction was measured on standing postoperative x-rays with Goal abduction (GA) of 30–50°.

PPO was obtained in 284/413 cases (69 %). Patient sex, weight, BMI, and operative laterality were not significantly associated with PPO. Patients with PPO were shorter (1.68m vs 1.72m, p < 0.01). PPO occurred in 168/221 patients (76 %) with the Capello or Wixson hip positioner, compared to 116/192 (60 %) with the De Mayo positioner (p < 0.01). GA was obtained in 249/284 (88 %) of patients with PPO, as compared to 103/129 (80 %) patients without PPO.

The risk of pelvic malpositioning significantly increases with the use of certain hip positioning systems, and taller patients. Acetabular component abduction is negatively affected by an improperly positioned pelvis.

Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

The number of total hip arthroplasty (THA) procedures performed annually in the United States is projected to reach over 600,000 by the year 2030.1,2 While there are various approaches to the hip for THA, the posterior approach remains the most utilized approach in the United States.3,4 The posterior approach requires the patient to be placed into the lateral decubitus position (LDP). Proper positioning in the LDP assumes that the longitudinal and coronal axes of the body are parallel and perpendicular to the floor, respectively, without pelvic tilt, rotation, or obliquity, as alteration in any of these parameters can influence acetabular orientation.5 To maintain the pelvis in this position throughout the procedure, various rigid positioning systems have been developed.

In 1978, Lewinnek et al. defined the safe zone for placement of the acetabular component to be 30°–50° of abduction, and 5°–25° of anteversion.6 While some recent studies question the validity of this safe zone,7–9 they continue to be utilized by many surgeons as a guide to approximate placement of the acetabular component. Mechanical external alignment jigs which rely on a properly positioned pelvis are commonly used to assess acetabular component positioning intra-operatively.

We sought to define variables that affect intraoperative pelvis positioning and discern whether the position of the pelvis affects the placement of the acetabular component. By comparing preoperative standing AP-pelvis x-rays and intraoperative lateral decubitus x-rays, and evaluating postoperative x-rays, we aim to1: Define variability and trends in pelvic positioning in the LDP,2 Determine demographic or clinical factors associated with improper intraoperative pelvic positioning,3 Investigate the effect that pelvic positioning has on acetabular component positioning. We hypothesized that there is wide variability in the position of the pelvis in the LDP, and that a malpositioned pelvis would result in improper placement of the acetabular component.

2

2 Materials and methods

Following IRB approval, a retrospective review of 813 consecutive cases of primary posterior THA performed in the LDP between January 2017–August 2020 at a single institution was completed. Procedures were performed by one of three adult reconstruction fellowship trained Orthopaedic surgeons who utilize intraoperative cross-table imaging, and each use a unique hip positioning system; Wixson (Innomed Savannah, GA), Capello (Innomed Savannah, GA), DeMayo (Imp Medical Plainville, CT).

Pelvic measurements were obtained utilizing the preoperative standing AP pelvis and intraoperative cross-table X-ray following the placement of the final acetabular cup and trial components. Acetabular component measurements were obtained utilizing the postoperative standing AP-pelvis x-ray. Two observers (YS and AT) performed all measurements. Definitions of pelvic tilt and rotation as previously described by Otero et al. were used.10

Patients with inadequate imaging (defined as an inability to accurately visualize the sacrococcygeal joint on AP pelvis x-ray), as well as procedures performed for revision, conversion, or fracture were excluded. No external funding was received for this study.

2.1

2.1 Pelvic variables and definitions

2.1.1

2.1.1 Pelvic tilt

Pelvic tilt was measured as the distance from the horizontal axis of the sacrococcygeal joint to a horizontal line tangential to the superior aspect of the pubic symphysis (Fig. 1). Using the preoperative x-ray as a baseline, pelvic tilt as a result of positioning was determined based on the difference in the measured distance when comparing preoperative and intraoperative x-rays.

Pelvic tilt; measured as the difference (V) between the horizontal axis of the sacrococcygeal joint (solid red line) and a horizontal line across the superior aspect of the pubic symphysis (dotted blue line) (Otero et al., reproduced with permission).
Fig. 1 Pelvic tilt; measured as the difference (V) between the horizontal axis of the sacrococcygeal joint (solid red line) and a horizontal line across the superior aspect of the pubic symphysis (dotted blue line) (Otero et al., reproduced with permission).
2.1.1.1
2.1.1.1 Forward pelvic tilt (inlet view)

Forward pelvic tilt was defined as when the coccyx was more cephalad on the intraoperative x-ray as compared to the preoperative x-ray (Fig. 2). Forward pelvic tilt was assigned a positive value.

Neutral vertical tilt (A) with the axis of the sacrococcygeal joint (red dot) and superior aspect of the pubic symphysis (blue dot) superimposed; Forward/positive tilt (B) with the axis of the sacrococcygeal joint (red dot) cephalad to the superior aspect of the pubic symphysis (blue dot); Backward/negative pelvic tilt (C) with the axis of the sacrococcygeal joint (red dot) caudad to the superior aspect of the pubic symphysis (blue dot) (Otero et al., reproduced with permission).
Fig. 2 Neutral vertical tilt (A) with the axis of the sacrococcygeal joint (red dot) and superior aspect of the pubic symphysis (blue dot) superimposed; Forward/positive tilt (B) with the axis of the sacrococcygeal joint (red dot) cephalad to the superior aspect of the pubic symphysis (blue dot); Backward/negative pelvic tilt (C) with the axis of the sacrococcygeal joint (red dot) caudad to the superior aspect of the pubic symphysis (blue dot) (Otero et al., reproduced with permission).
2.1.1.2
2.1.1.2 Backward pelvic tilt (outlet view)

Backward pelvic tilt was defined as when the coccyx was more caudad on the intraoperative x-ray as compared to the preoperative x-ray (Fig. 2). Backward pelvic tilt was assigned a negative value.

2.1.2

2.1.2 Pelvic rotation

Pelvic rotation was measured as the distance from the vertical long axis of the sacrum to the vertical long axis of the pubic symphysis (Fig. 3). Using the preoperative x-ray as a baseline, pelvic rotation as a result of positioning was determined based on the difference in the measured distance when comparing preoperative and intraoperative x-rays.

Pelvic rotation; measured as the difference (H) between the vertical long axis of the sacrum (red line) and the vertical long axis of the pubic symphysis (dotted blue line) (Otero et al., reproduced with permission).
Fig. 3 Pelvic rotation; measured as the difference (H) between the vertical long axis of the sacrum (red line) and the vertical long axis of the pubic symphysis (dotted blue line) (Otero et al., reproduced with permission).
2.1.2.1
2.1.2.1 Forward pelvic rotation (obturator oblique view)

Forward pelvic rotation was defined as when the axis of the sacrum moved towards the operative hip on intraoperative x-ray as compared to the preoperative x-ray (Fig. 4). Forward pelvic tilt was assigned a positive value.

Neutral horizontal rotation (D) with the axis of the sacrum (red dot) and axis of the pubic symphysis (blue dot) superimposed; Forward/positive rotation (E) with the axis of the sacrum (red dot) deviated towards the operative hip (green ellipse); Backward/negative pelvic rotation (F) with the axis of the sacrum (red dot) deviated away from the operative hip (green ellipse) (Otero et al., reproduced with permission).
Fig. 4 Neutral horizontal rotation (D) with the axis of the sacrum (red dot) and axis of the pubic symphysis (blue dot) superimposed; Forward/positive rotation (E) with the axis of the sacrum (red dot) deviated towards the operative hip (green ellipse); Backward/negative pelvic rotation (F) with the axis of the sacrum (red dot) deviated away from the operative hip (green ellipse) (Otero et al., reproduced with permission).
2.1.2.2
2.1.2.2 Backward pelvic rotation (iliac oblique view)

Backward pelvic rotation was defined as when the axis of the sacrum moved away from the operative hip on intraoperative x-ray as compared to the preoperative x-ray (Fig. 4). Backward pelvic tilt was assigned a negative value.

2.2

2.2 Acetabular component abduction

Acetabular component abduction was measured as the angle of inclination of the component from a horizontal line connecting the apices of the teardrops on the postoperative standing AP pelvis x-ray. A Cobb angle was obtained with one horizontal line connecting the apices of the bilateral teardrops with a second line was then drawn connecting the apices of the acetabular ellipse. The angle created between these lines was defined as the acetabular component abduction (Fig. 5).

Acetabular component abduction; measured as the angle of inclination from a line connecting the apices of the teardrops and a second line bisecting the ellipse of the acetabular component.
Fig. 5 Acetabular component abduction; measured as the angle of inclination from a line connecting the apices of the teardrops and a second line bisecting the ellipse of the acetabular component.
3

3 Statistical analysis

For each case, an average of the measurements from the two observers was used for statistical analysis. The differences in tilt and rotation between the standing AP pelvis and intra-operative cross table lateral were calculated. Proper pelvic orientation (PPO) was defined as an absolute value difference less than 15° in tilt and rotation. Non-proper pelvic orientation (nPPO) was defined as an absolute value difference greater than 15° in tilt and rotation. Patient baseline characteristics (sex, height, weight, BMI) and surgical determinants (laterality, positioning system) were compared between PPO and nPPO groups by using Chi-Square tests and Mann-Whitney U-tests for categorical and continuous variables, respectively. Binary logistic regression was used to assess the effect of the positioner on PPO. Odds ratio (OR) with 95 % confidence interval was reported. P-value less than 0.05 was accepted as statistical significance. IBM SPSS version 25 was used for statistical analysis.

4

4 Results

We analyzed 813 consecutive cases (740 patients) of primary THA from January 1, 2017 to August 30, 2020 performed through a posterior approach in the lateral decubitus position. Following application of exclusion criteria, 413 cases were included in the analysis.

Regarding intraoperative pelvic positioning, pelvic tilt ranged from −29° to 30°, with an average of 5° (inlet view). 88 % (n = 362/413), 11 % (n = 47/413), and 1 % (n = 4/413) of cases had an intraoperative pelvic tilt measurement that ranged from ± 15°, ± 15-25°, and > ±25°, respectively (Fig. 6). Pelvic rotation ranged from −41°- 71°, with an average of 5° (obturator oblique view). 77 % (n = 316/413), 18 % (n = 73/413), and 6 % (n = 24/413) of cases had an intraoperative pelvic rotation measurement that ranged from ± 15°, ± 15-25°, and > ±25°, respectively (Fig. 6). 69 % (n = 284/413) of cases were positioned with pelvic tilt and rotation within ± 15°, proper pelvic orientation (PPO) (Fig. 6).

Distribution of pelvic tilt (solid grey bar) and rotation (dashed grey bar) measurements in our population. Vertical bars denoting cutoff for PPO.
Fig. 6 Distribution of pelvic tilt (solid grey bar) and rotation (dashed grey bar) measurements in our population. Vertical bars denoting cutoff for PPO.

The average patient age was 59 (SD 11.8 years), with a range from 18 to 87 years. 238 patients (58 %) were men, and 175 patients (42 %) were women. Patient age, gender, weight, and BMI were not significantly different between PPO and nPPO cohorts (Table 1). The average height of patients with PPO (1.68m ± 0.1) were significantly shorter compared to patients with nPPO (1.72m ± 0.1) (p < 0.01), which maintained significance with gender stratification.

Table 1 Patient and clinical demographics.
Total n = 413 nPPO n = 129 PPO n = 284 p-value OR
Age, mean (STD) 59 (11.8) 58.2 (11.5) 59.4 (12.0) 0.3
Gender 0.7 0.93 (0.61–1.41)
Female 175 (42 %) 53 (30 %) 122 (70 %)
Male 238 (58 %) 76 (32 %) 162 (68 %)
Height (m) 1.69 (0.1) 1.72 (0.1) 1.68 (0.1) <0.01
Female 1.64 (0.07) 1.60 (0.09) 0.02
Male 1.78 (0.08) 1.74 (0.08) <0.01
Weight (kg) 87.8 (20) 89.9 (21.5) 86.8 (19.1)
Female 82.9 (21.6) 79.4 (18.5) 0.3
Male 94.7 (20.2) 92.4 (17.7) 0.5
BMI 30.5 (6.1) 30.6 (6.4) 30.4 (6.0)
Female 31.6 (7.2) 30.9 (6.8) 0.5
Male 30.0 (5.7) 30.1 (5.4) 0.9
Laterality 0.6 0.91 (0.6–1.4)
Right 201 (49 %) 65 (32 %) 136 (68 %)
Left 212 (51 %) 64 (30 %) 148 (70 %)
Positioning System <0.01
DeMayo (ref) 192 (46 %) 76 (59 %) 116 (41 %)
Wixson 159 (39 %) 43 (33 %) 116 (41 %) 1.8 (1.1–2.8)
Capello 62 (15 %) 10 (8 %) 52 (18 %) 3.4 (1.6–7.1)
Abduction 0.04 1.8 (1.0–3.1)
Safe 352 (85 %) 103 (80 %) 249 (88 %)
Out 61 (15 %) 26 (20 %) 35(12 %)

Each surgeon used a unique hip positioning system; these included the Wixson (n = 159, 38 %), DeMayo (n = 192, 46 %), and Capello (n = 62, 15 %) hip positioning systems. PPO and nPPO distribution was significantly different among the three positioning systems (Fig. 7). PPO was observed in 84 % (n = 52/62), 73 % (n = 116/159), and 60 % (n = 116/192) within the Capello cohort, Wixson cohort, and DeMayo cohort, respectively (p < 0.01). Binary logistic regression analysis showed that as compared to the DeMayo system, the Wixson and Capello systems are 1.7 (95 % CI, 1.1–2.8) and 3.4 (95 % CI, 1.6–7.1) times more associated with obtaining PPO (p < 0.01), respectively. Goal abduction (GA) was obtained in 88 % (n = 249/284) of cases in the PPO cohort, as compared to only 80 % (n = 103/129) of cases in the nPPO cohort (OR [95 % CI] = 1.8 [1.0–3.1], p = 0.04) (Table 1).

Distribution of cases defined as PPO (blue) and nPPO (grey) stratifies based on positioning system used.
Fig. 7 Distribution of cases defined as PPO (blue) and nPPO (grey) stratifies based on positioning system used.
5

5 Discussion

There is high variability in the orientation of the pelvis between the lateral decubitus and standing position. Our study found horizontal tilt discrepancy to be as high as 30° and axial rotation discrepancy to be as high as 70°. Without the comparison of standing AP pelvis x-rays and using only intraoperative x-rays, Otero et al.10 noted similar rates of variability in the lateral decubitus position with tilt discrepancy as high as 32.5° and rotation discrepancy as high at 32.3° from neutral. We compared pelvic tilt and rotation in the lateral decubitus position to orientation in the standing position to account for patient-specific variations in the spine-pelvis relationship. When compared to the anatomic standing orientation of the pelvis, only 68 % of cases were positioned with both pelvic variables within ± 15° of the anatomic standing orientation. Analyzing the effects of demographic and clinical patient factors on intraoperative pelvic positioning, we found that taller patients were more commonly associated with malpositioning. It is possible that these positioning systems fail to fully capture and stabilize taller patients.

Comparing the three positioning systems used, there was an increased rate of malpositioning when using the DeMayo positioning system. When using the DeMayo system, there was a 1.7x and 3.4x greater risk for malposition as compared to the Wixson and Capello systems respectively. To our knowledge, there are no other studies analyzing the association between different positioning systems intraoperative on pelvic orientation.

A recent study by Milone et al.5 also showed wide variability in acetabular anteversion in the LDP while using a robotic-assisted computer navigation system to assess the reliability of rigid positioning systems. Two positioning systems were used; however, there was no comparison made regarding the rate of pelvic malpositioning between the positioning systems, and no comment was made regarding the final effect on component abduction. Our data suggests the potential negative effect of improper pelvic positioning on component abduction.

Placement of the acetabular component remains one of the most technically difficult aspects of THA.9 As such, multiple tools have been developed to assist surgeons with this crucial step: external alignment guides, anatomic landmarks, intraoperative x-rays, and navigation systems. While mechanical alignment jigs are readily available and offer a low-cost option with relative ease of use, these external jigs rely on consistent and reproducible patient positioning. Previous studies have demonstrated wide variability in pelvic positioning, arguing against the use of external alignment jigs due to the variability.6,12 Alternatively, anatomic landmarks such as the transverse acetabular ligament and labrum obviate the need for precise patient positioning. However, these landmarks may be altered in patients with significant osteophytes and are unidentifiable intraoperatively in upwards of 50 % of cases, and their intra-operative accuracy as an assessment of inclincation has been called into question.11,13 Fluoroscopic assessment in the lateral decubitus position has been shown to increase operative time as it is difficult to perform, and inaccuracies have been documented in previous studies.14,15 CT-based and imageless navigation systems allow quick and precise calculations of anteversion, abduction and other parameters such as center of rotation and offset.16 However, there is a learning curve and additional cost associated with the use of these techniques. Additionally, previous studies have found that pelvic tilt can cause inaccuracies with this type of navigation.17 Although many techniques are employed to assist in the accurate placement of the acetabular component, there remains variability in inter-surgeon and intra-surgeon component orientation and a widely accepted gold standard method has yet to be developed.18 Decreasing variability in pelvis orientation in the lateral decubitus position may improve proper component placement.

There were multiple limitations with this study. Due to the retrospective design, methods for positioning the patient and obtaining the intraoperative cross-Table x ray were not standardized. Our methodology does not account for any changes in the operating table orientation that may have been performed intraoperatively. Since intraoperative x-rays were obtained after placement of final acetabular component and trial femoral components, we are unable to comment on the accuracy of positioning of the pelvis after initial positioning. Finally, the quality of a subset of x-rays made crucial anatomic landmarks unidentifiable leading to the exclusion of these patients from the study, resulting in a potential source of selection bias.

6

6 Conclusion

Pelvis orientation in the LDP is highly variable. Our data demonstrates a significant increase in the rate of pelvic malpositioning with taller patients and the use of certain hip positioning systems. There is a significant risk of placing the acetabular component outside of the Lewinnek safe zone for abduction when the pelvis is positioned in >15 degrees of tilt and rotation from the anatomic orientation. Orthopaedic surgeons performing THA should be aware of these risks to avoid component malpositioning.

CRediT authorship contribution statement

Daniel J. Sherwood: Conceptualization, Formal analysis, Investigation, Data curation, Writing – original draft. Hemant Reddy: Conceptualization, Data curation, Writing – original draft. Xiuyi A. Yang: Conceptualization, Data curation, Writing – review & editing. Yoav Zvi: Conceptualization, Formal analysis, Writing – original draft. Zeynep Seref-Ferlengez: Conceptualization, Formal analysis, Visualization. Yonatan Schwartz: Data curation, Resources. Anna Tarasova: Data curation, Investigation. Eli Kamara: Conceptualization, Formal analysis, Writing – review & editing, Project administration, Supervision.

Ethical statement

All procedures of this study were performed in accordance with the Montefiore Einstein Center for Bioethics. The study was performed with approval from the Montefiore IRB committee (IRB# 2019–10284). The study performed does not include human tissue samples. The study was performed in written to be in accordance with the Recommendations for the Conduct, Reporting, Editing, and Publication of Scholarly Work in Medical Journals.

Funding statement

For authors DJS, HR, XAY, YZ, ZSF, YS, AT, EK there are no conflict of interest. No authors or their family members have received any funding or royalties from any governmental or private entities. There has not been any financial funding for the production of this study.

References

  1. , , , . Projected volume of primary total joint arthroplasty in the U.S., 2014 to 2030. J Bone Joint Surg Am. 2018;100(17):1455-1460.
    [Google Scholar]
  2. , , . Improving the accuracy of acetabular component orientation: avoiding malposition. J Am Acad Orthop Surg. 2010;18(5):286-296.
    [Google Scholar]
  3. , , , , . Anterior vs. posterior approach for total hip arthroplasty, a systematic review and meta-analysis. J Arthroplast. 2015;30(3):419-434.
    [Google Scholar]
  4. , , , , , , . Rigid patient positioning is unreliable in total hip arthroplasty. J Arthroplast. 2017;32(6):1890-1893.
    [Google Scholar]
  5. , , , , , . Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60(2):217-220.
    [Google Scholar]
  6. , , , , , . What safe zone? The vast majority of dislocated THAs are within the Lewinnek safe zone for acetabular component position. Clin Orthop Relat Res. 2016;474(2):386-391.
    [Google Scholar]
  7. , , , et al . Can a target zone safer than Lewinnek's safe zone be defined to prevent instability of total hip arthroplasties? Case-control study of 56 dislocated THA and 93 matched controls. Orthop Traumatol Surg Res. 2017;103(5):657-661.
    [Google Scholar]
  8. , , , , . Functional safe zone is superior to the Lewinnek safe zone for total hip arthroplasty: why the Lewinnek safe zone is not always predictive of stability. J Arthroplast. 2019;34(1):3-8.
    [Google Scholar]
  9. , , , , , . Variability of pelvic orientation in the lateral decubitus position: are external alignment guides trustworthy? J Arthroplast. 2018;33(11):3496-3501.
    [Google Scholar]
  10. , , , . Acetabular component positioning using the transverse acetabular ligament: can you find it and does it help? Clin Orthop Relat Res. 2011;469(2):412-416.
    [Google Scholar]
  11. , , , , , . Placement of the acetabular component. Bone Joint Lett J. 2016;98-B(1 Suppl A):37-43.
    [Google Scholar]
  12. , , , et al . The role of the transverse acetabular ligament for acetabular component orientation in total hip replacement: an analysis of acetabular component position and range of movement using navigation software. J Bone Joint Surg Br. 2011;93(8):1021-1026.
    [Google Scholar]
  13. , , , , . A novel device to measure acetabular inclination with patients in lateral decubitus. Hip Int. 2012;22(6):683-689.
    [Google Scholar]
  14. , , , , , . Accuracy of intraoperative assessment of acetabular prosthesis placement. J Arthroplast. 1998;13(1):80-84.
    [Google Scholar]
  15. , , , , , , . Does intraoperative fluoroscopy improve component positioning in total hip arthroplasty? Orthopedics. 2015;38(1):e1-e6.
    [Google Scholar]
  16. , , , , . Pelvic tilt makes acetabular cup navigation inaccurate. Acta Orthop. 2005;76(4):517-523.
    [Google Scholar]
  17. , , , , . What do we get from navigation in primary THA? EFORT Open Rev. 2017;1(5):205-210.
    [Google Scholar]
Show Sections