Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical research study
Current Issue
Editorial Board
Literature Review
Narrative review
Original Article
Research Article
Review Article
Short Report
Surgical techniques
Systematic Review and Meta-Analysis
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical research study
Current Issue
Editorial Board
Literature Review
Narrative review
Original Article
Research Article
Review Article
Short Report
Surgical techniques
Systematic Review and Meta-Analysis
View/Download PDF
19 (); 72-75
doi:
10.1016/j.jor.2019.11.025

Translate:

Does negative pressure intrusion cementing technique improve the cement penetration under the tibial component? A comparative retrospective study

Author affiliations
Unità di Chirurgia Protesica, Orthopaedic Institute of Southern Italy “Franco Scalabrino”, Messina, Italy
Article History
Corresponding author(s)

∗Corresponding author: Giorgio Cacciola. dr.cacciola@gmail.com

Article tools · PDF & citations

Abstract

Abstract

Intramedullary suction cementing technique of the tibial component has the theoretical advantage to allow a deeper cement penetration trough the cancellous bone. The aim of this study is to compare the cement penetration under the tibial component between patients that underwent tibial component cementation with or without the use of intramedullary suction. Two-hundred-twenty-four patients underwent primary total knee arthroplasty (TKA) during the study period, One-hundred-twenty-two TKAs using intramedullary suction with negative pressure (55.4%), while one-hundred-two TKAs without intramedullary suction (44.6%). We found that the intra-operative suction during cement application increase the depth of cement penetration better than pulsed lavage alone.

Keywords

  • Cementing technique
  • Intramedullary suction
  • Total knee arthroplasty
  • TKA
Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

Total Knee arthroplasty (TKA) is a safe and common surgical procedure, in US more than 600.000 surgeries are performed each year1; the benefits obtained after a TKA (pain relief and restoration of function) can be maintained for a long period (further than 20 years).1,2 The 2018 Annual Report of the Australian Arthroplasty Registry of Hip, Knee and Shoulder, stated that the most frequent cause of TKAs revision is the loosening of the tibial component.3 There is no shared consensus about which is the mechanism that cause the loosening, but often a progressive radiolucent line (RL) is seen at the bone-cement interface.4

The thickness of cement mantle is directly related to the mechanical properties of bone-cement and cement-implant interfaces, as compressive strength, bending strength and bending modulus. In addition, an adequate cement penetration assure fixation, primary stability and longevity of the tibial component.5 The first clinical studies focused on the appropriate depth of cement penetration were carried in the early ’80. Walker et al.,6,7 defined optimal a cement mantle between 3 and 4 mm, while Krause et al.,8,9 extend the safe area between 2 and 5 mm. Today, there is a shared consensus that the optimal depth of cement penetration must be between 3 and 5 mm.10,11

The depth of cement penetration depend from several factors, as bone density, viscosity of cement, use of pulsed lavage, dry the bone surface.10 In the present study we want to evaluate the effect of intramedullary suction during bone preparation and cement application phases on the depth of cement penetration. Recently, we introduced a novel tourniquet-less bone preparation technique in which the tibial surface is cleaned by pulsed lavage, and than it's dried with gauzes, while an intramedullary negative pressure is applied during all the bone preparation and cement application phases. This technique has the theoretically advantages to reduce the blood and soft tissues remnants within the cancellous bone allowing a deeper cement penetration and a better interdigitation. Currently, there are only few studies that report the results of cement technique using an intramedullary continue suction during cement application.12,13 At our knowledge, this is the first study that reports the results of a tourniquet-less cementing technique with suction on the intramedullary tibial canal during bone preparation and cement application phases. Therefore, the aim of this study is to compare the cement penetration under the tibial component in two groups: (1) tourniquet-less, pulsed lavage group, (2) and tourniquet-less, pulsed lavage and intramedullary suction group.

2

2 Materials and methods

After obtaining institutional review board approval, a retrospective analysis of patients that underwent primary TKAs for osteoarthritis between January and December 2016 at our institution by the senior surgeon was performed. All the surgeries were performed using the same knee prosthesis design, K-Mod (Gruppo Bioimpianti, Peschiera Borromeo, Milan, Italy) and the same cement, G3 Low-Viscosity Bone Cement (G21, San Possidonio, Modena, Italy).

2.1

2.1 Surgical technique

A midline incision and a medial parapatellar approach was used for all surgeries. After fat pad excision, the patella was everted. The prosthesis fixation was obtained by a complete one stage cementing technique with a low-viscosity bone cement. Tibial cut on the coronal plane was performed perpendicular to the tibial anatomical axis, using an extramedullary guide. On the sagittal plane, we aimed to restore the native posterior slope according to the preoperative radiographic measurement. The tibial slope cut ranged from 3 to 7°. The distal femoral cut was performed with a valgus angle of three up to seven degrees on the femoral anatomical axis. The femoral component was 3° externally rotated concerning the posterior condylar angle. To improve cement penetration, in case of sclerotic bone a drill hole was used. Low-Viscosity bone cement was mixed with 1gr of genatmicin. A one stage cementing technique was used. A pulsed lavage was performed for at least 1 minute. Cement was applied using a pressurized gun only to the upper surface of the tibial metaphysis (Fig. 1). The only difference in the cementing technique between the two groups was the application of the suction cannula and negative pressure in the intramedullary tibial canal (Fig. 2).

Cement Application in the suction group: (a) The Bone cement is applis trough a pressurized gun on the upper surface of the tibial plate. No cement in inserted on the tibial intramedullary canal. A suction cannula is placed at the entry of the medullary canal to prevent incidental cement leakage. (b) A negative pressure is constatly applied in the suction cannula to remove blood and soft tissue remnants and to facilitate the interdigitation of cement within the cancellous bone.
Fig. 1 Cement Application in the suction group: (a) The Bone cement is applis trough a pressurized gun on the upper surface of the tibial plate. No cement in inserted on the tibial intramedullary canal. A suction cannula is placed at the entry of the medullary canal to prevent incidental cement leakage. (b) A negative pressure is constatly applied in the suction cannula to remove blood and soft tissue remnants and to facilitate the interdigitation of cement within the cancellous bone.
Suction Cannula Application: (a) A suction cannula is applied on the top of the tibial hole to prevent cement leakage on the tibial medullary canal and to facilitate cement penetration trough the cancellous bone. (b) Douring the doughing of the bone cement the suction cannula continue to suck blood and fatty marrow enhancing the interface between bone and cement.
Fig. 2 Suction Cannula Application: (a) A suction cannula is applied on the top of the tibial hole to prevent cement leakage on the tibial medullary canal and to facilitate cement penetration trough the cancellous bone. (b) Douring the doughing of the bone cement the suction cannula continue to suck blood and fatty marrow enhancing the interface between bone and cement.
2.2

2.2 Radiographic assessment

All radiographs were acquired by the same radiologist technician and observed by a fellowship-trained Orthopaedic Surgeon. A post-operative standardized anteroposterior and lateral views of the knee were acquired one week after surgery to evaluate the depth of cement penetration. The depth of cement penetration was measured using a modified scheme of the zones of the Knee Society Radiographic Evaluation System at the tibial component (Fig. 3). In addition, for cement penetration we considered the sum of the mean values of the radiographic zone as overall value. Measurements were performed at the 1 month post-operative radiographs on digital radiographs calibrated on a 3 cm metallic sphere. Measurements were performed by two authors, discrepancies greater than 1 mm were resolved by a third measurement performed by a third author.

Modified Zones of Knee Society Radiographic Evaluation System: (AP = antero-posterior view) (LL = lateral view) (m = medial side) (l = lateral side). For the present study we used a modified version of the Knee Society Radiographic Evaluation System. We did not consider the area in proximity to the tibial keel because we don't put cement in the tibial canal.
Fig. 3 Modified Zones of Knee Society Radiographic Evaluation System: (AP = antero-posterior view) (LL = lateral view) (m = medial side) (l = lateral side). For the present study we used a modified version of the Knee Society Radiographic Evaluation System. We did not consider the area in proximity to the tibial keel because we don't put cement in the tibial canal.
2.3

2.3 Statistical analysis

All data were recorded by two authors and collected into Prism 6 (GraphPad, La Jolla, California, USA) statistical analysis software. Mann-Whitney test was used to assess differences between the two groups, a p-value < 0.05 was considered statistically significant.

3

3 Results

3.1

3.1 Demographic

Two-hundred twenty four TKAs were performed on two-hundred eleven patients, with a mean age of 64.4 years (standard deviation 7.5 years), there were one-hundred-twenty-seven women (60.2%) and eighty-four men (39.8%). One-hundred-twenty-two TKAs were performed using intramedullary suction with negative pressure (55.4%), while one-hundred-two TKAs were performed without intramedullary suction (44.6%). Demographic data are listed in Table 1, no differences were found between the two groups for age, sex, side and body mass index.

Table 1 Demographic data.
Variable Suction Group No Suction Group p-value
Demographic (n = 211)
Mean Age (years) 65.6 (SD 7.6) 63.8 (SD 7.3) 0.876
Sex: Women 69 (56.6%%) 58 (56.9%) 0.765
Side: Right 64 (52.5%) 48 (47.1%)
Body Mass Index
3.2

3.2 Cement penetration

The depth of cement penetration was measured and compared in the whole eight region of interest (Fig. 4). A statistically significant differences between the two groups was observed in zones II, III, VI and VII (p < 0.05), while no differences were observed in region I, IV, V and VIII (p > 0.05). The mean depth of cement penetration was greater in the suction group than the non-suction group, respectively 4.3 mm and 3.6 mm (p < 0.05).

Depth of cement penetration in the eight zones of modified Knee Society Radiographic Evaluation System. A statistically significant differences was found in zones II, III, VI, VII and for the mean of the depth in all the eight zones.
Fig. 4 Depth of cement penetration in the eight zones of modified Knee Society Radiographic Evaluation System. A statistically significant differences was found in zones II, III, VI, VII and for the mean of the depth in all the eight zones.
4

4 Discussion

Our hypothesis is that the application of negative pressure inside the medullary tibial canal could reduce the presence of blood within the cancellous bone and could help to remove the soft tissue remnants after finishing using pulsed lavage. At our knowledge only two studies report the results of similar techniques as the one proposed in the present study.12,13 Norton et al.13 used a trochar placed into the medullary tibial canal connected to a negative pressure of 125 kPa, they use pressurized lavage and gauze to dry the bone surface, and apply the cement manually. They found in a case series of 18 patients a significant increased cement penetration into cancellous bone than in the other groups. Stannage et al.12 in addition to the suction of the medullary canal, used also two Wolfe needle applied 2 cm below the tibial cut surfaces connected via a y tube. They found in a case series of 46 patients that the use of irrigation and suction under the tibial baseplate in total knee arthroplasty allow to achieve optimal results. Using our cementing technique a reproducible and adequate depth of cement penetration was observed in each of the eight zones (Fig. 4). The optimal depth of cement penetration is between 3 and 5 mm.6–11 A shorter cement penetration could raise the risk of presence of post-operative radiolucency's line and early implant mobilization due to lack of cohesive strength at the bone cement interface.7 On the other hand, a cement penetration greater than 5 mm is associated with thermal necrosis of surrounding bone and soft tissue leading to potential aseptical mobilization of the implant.16 Four radiographic zones (II,III,VI and VII) showed a significant greater depth of cement penetration between the suction and non-suction groups of patient. These four zones are close the intramedullary canal suction cannula and are the most affected by the negative pressure. The depth of cement penetration in zones I, IV, V and VIII is partially affected by intramedullary negative pressure, and there is no a statistically significant differences between the two groups. Our results are in line with the previous studies that used similar cementing technique12,13

Previous studies have reported that the use of pulsed lavage enhance the cement penetration into cancellous bone and improve the fixation strength between bone-cement and cement-implant interfaces in both unicompartimental knee arthroplasty14,15 and TKAs. Schlegel et al.,16 in a study with twelve paired proximal third of fresh-frozen cadaveric tibiae, founded that the median pull-out forces was significantly greater when pulsed lavage was used instead of syringe lavage, respectively the pullout forces were 1275 N and 578 N. Theoretically the use of tourniquet during TKA should provide to improve visualization of structures, reducing intraoperative and post-operative bleeding and consequently allow to obtain a better cement penetration. Recent studies states that there is no difference in terms of blood loss and cement penetration comparing two group of patients (with and without Tourniquet). Alcelik and colleagues17 performed a systematic review and meta-analysis comparing the outcomes of the two different groups of patients founding no statistically significant differences in terms of surgery duration; total, intraoperative, and postoperative blood losses; deep vein thrombosis; pulmonary embolism; and minor/major complications In a recent paper, Schnettler et al.18 have found very interesting results. They affirm that using tourniquet in TKA results in a paradoxical increase in total blood loss. The debate of using of Tourniquet during TKA is still open, our surgical technique involves the placement of the Tourniquet band at the medial third of the femur but without using it (it will be used only in case of major vascular complication). The previously reported articles support out choice to not use Tourniquet during TKA. Our hypothesis is that the using of pulsed lavage, dry of the bone surface and tibial suction during cementation could substitute the role of Tourniquet of maintaining a clean bone surface avoiding the risk of developing vascular complications.

This study has some limitation. First of all the follow-up in shorter, all the surgeries were performed between January and December 2016, and today no revision due to aseptical loosening of the tibial component were observed. Another limitation is the missing data related to the bone density that is one of the most important factors that change the depth of cement penetration. On the other hand, this study has some point of strength. This is the largest case series that report results using an intramedullary suction during TKAs, and the two group did not differ for age, sex, side and mean body mass index.

To the authors’ knowledge this is the first clinical study that evaluate the depth of cement penetration using a tourniquet-less TKA, pulsed lavage and intra-operative suction. These results suggest that the intra-operative suction during cement application increase the depth of cement penetration better than pulsed lavage alone. The negative pressure applied into the intramedullary canal may lead to a better removal of blood, fatty marrow and soft tissue remnants, and consequently could reduce the risk of early and late tibial component loosening. A longer follow-up analysis of this case series of patients must be performed in order to observe if there are differences in long-term survivorship of the implant.

References

  1. , , , et al . Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002. J Bone Joint Surg Am. 2005;87(7):1487-1497.
    [Google Scholar]
  2. , , , et al . The epidemiology of revision total knee arthroplasty in the United States. Clin Orthop Relat Res. 2009;468(1):45-51.
    [Google Scholar]
  3. , .
    [Google Scholar]
  4. , , , . Radiolucent lines below the tibial component of a total knee replacement (TKR)--a comparison between single-and two-stage cementation techniques. Int Orthop. 2008;32(4):453-457.
    [Google Scholar]
  5. , , , . Mechanical and elution properties of G3 Low Viscosity bone cement loaded up to three antibiotics. J Orthop. 2018;15(4):1004-1007.
    [Google Scholar]
  6. , , et al . Control of cement penetration in total knee arthroplasty. Clin Orthop Relat Res (185):155-164.
    [Google Scholar]
  7. , , , . A cement impactor for uniform cement penetration in the upper tibia. Clin Orthop Relat Res (182):206-210.
    [Google Scholar]
  8. , , . Fatigue properties of acrylic bone cements: review of the literature. J Biomed Mater Res. 1988;22(A1 Suppl):37-53.
    [Google Scholar]
  9. , , , . Strength of the cement-bone interface. Clin Orthop Relat Res (163):290-299.
    [Google Scholar]
  10. , , , et al . Cementing the tibial component in total knee arthroplasty: which technique is the best? J Arthroplast. 2011;26(3):492-496.
    [Google Scholar]
  11. , , et al . Cementing techniques for the tibial component in primary total knee replacement. Bone Joint Lett J. 2013;95-B(3):295-300.
    [Google Scholar]
  12. , , , . Suction technique to improve cement penetration under the tibial component in total knee arthroplasty. The Knee. 2003;10(1):67-73.
    [Google Scholar]
  13. , , . Irrigation and suction technique to ensure reliable cement penetration for total knee arthroplasty. J Arthroplast. 2000;15(4):468-474.
    [Google Scholar]
  14. , , , et al . The effect of bone lavage on femoral cement penetration and interface temperature during Oxford unicompartmental knee arthroplasty with cement. J Bone Joint Surg Am. 2013;95(1):48-53.
    [Google Scholar]
  15. , , , et al . Effect of lavage and brush preparation on cement penetration and primary stability in tibial unicompartmental total knee arthroplasty: an experimental cadaver study. The Knee. 2017;24(2):402-408.
    [Google Scholar]
  16. , , , et al . Modifications of poly(methyl methacrylate) cement for application in orthopedic surgery. Adv Exp Med Biol. 2018;2018(1078):119-134.
    [Google Scholar]
  17. , , , et al . A comparison of outcomes with and without a tourniquet in total knee arthroplasty: a systematic review and meta-analysis of randomized controlled trials. J Arthroplast. 2012;27(3):331-340.
    [Google Scholar]
  18. , , , . Use of a tourniquet in total knee arthroplasty causes a paradoxical increase in total blood loss. J Bone Joint Surg Am. 2017;99(16):1331-1336.
    [Google Scholar]
Show Sections