View/Download PDF
55 (); 1-10
doi:
10.1016/j.jor.2024.03.041

Translate:

All-inside posterior cruciate ligament reconstruction – A systematic review of current practice

Author affiliations
Changi General Hospital, 2 Simei St 3, Singapore, 529889
Article History
Corresponding author(s)

⁎Corresponding author: Jun Rui Don Koh. kohjrd92@gmail.com

Article tools · PDF & citations

Abstract

Abstract

The All-Inside PCL Reconstruction is a surgical technique which overcomes some of the key challenges faced with traditional PCL Reconstruction, and is becoming more relevant as the rate of PCL reconstruction increases.

The purpose of this study is to review the technical practices of the all-inside PCL reconstruction since it was first introduced, with respect to the various key components involved in the surgical technique, to provide more information to the surgeon of the various surgical options available in practice.

A systematic review was performed by the authors in January 2023 as per Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) guidelines to identify all studies outlining the all-inside surgical technique in the past decade. The predetermined eligibility criteria were applied in the screening of the literature in Pubmed, Cochrane and Google Scholar databases.

A total of 14 studies were included in the final review, 9 technical studies, 2 case series, 2 book chapters and 1 review. An allograft was the preferred choice in 9 of the 14 studies. The semitendinosus was preferred when an autograft was chosen. Quadruple folding of the graft was the preferred configuration in 11 studies with the graft diameters from 8 to 12 mm and length ranging from 60 to 150 mm. The femur socket length ranged from 15 to 35 mm and the tibia socket length ranged from 20 to 70 mm. All the studies reported the use of at least 3 portals and up to 6 portals was also reported. 13 studies reported the graft docking first into tibia socket followed by the femoral socket. 7 studies reported the graft entry via the AM portal and 6 studies used a lateral portal. 9 studies used augmentation such as suture anchors (6 studies) and suture tape (3 studies). The 30° and 70° arthroscopic lenses were used alternatingly in 8 studies and fluoroscopy was utilized in 10 studies.

The current literature review of all-inside PCL reconstruction consisted mainly technical studies and more clinical outcomes studies are needed to determine its efficacy. It observed a trend to use an allograft, at least 3 portals and docking the graft in the tibia socket first. There is no obvious preference of portal for graft entry.

Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

The all-Inside surgical technique was first described in 1995 for anterior cruciate ligament (ACL) reconstruction.1,2 The evolution of the surgical technique and promising early clinical outcomes3 have led to the application in posterior cruciate ligament (PCL) reconstruction from as early as 2012.4

PCL reconstruction using the all-inside technique has been less reported largely in part due to the much lower incidence of PCL injury being approximately 3% of all knee injuries, compared to the ACL injury being more than 50%.5 The reported incidence of PCL injuries varies among the studies ranging from 1 to 44%6 and is likely related to the differences in study populations involved in sports and trauma.7 Conservative management has been widely considered acceptable in isolated PCL injuries with good long term outcomes,8 including a majority (84%) returning to sports.9 Surgical management is indicated for PCL injury when it is symptomatic, of grade II in laxity, or as part of a multiple ligament knee injury (MLKI). However, a trend of 13% increase in PCL reconstruction in the past decade had been reported.10 The all-inside technique addresses a number of the associated technical challenges in a traditional PCL reconstruction technique, including the graft passage through the tibia tunnel and circumventing the ‘killer turn’. Another possible benefit of this technique also includes the additional adjustment of graft tension, and potentially reducing graft usage. Lastly, reduction in post-operative pain is another potential benefit as there is a conservation of bone, and reduction in the breach of cortical bone with this technique.

Much of existing literature with regards to the All-Inside technique describes each authors' individual preference for surgery. Despite the rise in the number of PCL surgeries, to the best of the author's knowledge there is no available literature reviewing the various components involved in the All-Inside PCL reconstruction technique such as graft source and dimension, portal utilization and adjunct equipment usage.

As the rate of PCL Reconstruction, and similarly the use of the All-Inside PCL Reconstruction technique increases, the authors of this paper aim to provide an overview of the trends in current practice of the various components involved in the All-Inside PCL Reconstruction technique, and serve as a knowledge update for surgeons aiming to take up this technique to incorporate the best practices possible.

2

2 Materials and methods

2.1

2.1 Systematic review

In January 2023, a systemic review of existing literature since 2010 was performed by 2 independent reviewers with the search being performed with respect to Preferred Reporting Items for Systematic Review and Meta-analysis Guidelines11 (PRISMA). The Pubmed, Cochrane and Google Scholar databases were screened for papers containing the terms; all-inside and posterior cruciate ligament (see attached in appendix). A total of 65 articles were first collated during the initial database search. Duplicate studies (n = 21) were removed, and the titles and abstracts of the remaining studies (n = 44) were screened manually by both independent reviewers whilst applying our predetermined exclusion criteria. The predetermined exclusion criteria decided upon by both authors included the following: (1) Biomechanical studies (2) Abstract only studies (3) Cadaveric studies (4) Studies published in languages other than the English language. Following removal of excluded studies (n = 13), predetermined inclusion criteria was then applied for definitive inclusion. The predetermined inclusion criteria decided upon by both authors included the following: (1) Studies detailing the All-inside PCL Surgical technique (2) Published in a peer-review journal with full text available. Finally, the remaining 14 studies which were eligible for this study first had their quality assessed using a critical appraisal tool.12,13 The Preferred Reporting Items for Systematic Review and Meta-Analysis Flow Chart with reasons for exclusion is illustrated in Fig. 1.

Search results PRISMA flow chart. PRISMA, Preferred Reporting Items for Systematic Review and Meta-Analysis.
Fig. 1 Search results PRISMA flow chart. PRISMA, Preferred Reporting Items for Systematic Review and Meta-Analysis.
2.2

2.2 Data extraction

The 14 studies included in this paper then had information relating to pre-determined respective components of the All-Inside PCL Reconstruction surgical technique extracted individually by both authors. In the event of discrepancy over the interpretation of the information detailed in the results, the authors would convene and come to a mutual agreement. As the papers reviewed had no significant data points, no statistical analysis was performed. Ethical approval was not required for this paper. The respective components of the All-Inside PCL reconstruction technique which were identified for data extraction is illustrated in Fig. 2.

Identified key components of the all-inside PCL reconstruction surgical technique.
Fig. 2 Identified key components of the all-inside PCL reconstruction surgical technique.
3

3 Results

A total of 14 studies were included in our paper – 9 technique, 2 case series, 2 book chapters and 1 review paper. The studies included described reconstruction in both isolated and multi-ligament injuries. Of the 14 papers, 9 of them described debridement of the remnant PCL in their technique. The Authors, title of paper, year of publication and type of study are displayed below in Table 1.

Table 1 Author, Title, Publication year and study type for papers included.
No. Authors Title Publication year Type of study Level of evidence
1 Slullitel et al. Double-Bundle “All-Inside” Posterior Cruciate Ligament Reconstruction 2012 Technique V
2 Nancoo et al. TransMedial All-Inside Posterior Cruciate Ligament Reconstruction Using a Reinforced Tibial Inlay Graft 2013 Technique V
3 Adler All-Inside Posterior Cruciate Ligament Reconstruction With a GraftLink 2013 Technique V
4 Bait et al. Posterior cruciate ligament reconstruction with “all-inside” technique: a technical note 2014 Technique V
5 King et al. All-Inside Posterior Cruciate Ligament Reconstruction 2015 Technique V
6 Prince et al. All-Inside Posterior Cruciate Ligament Reconstruction: GraftLink Technique 2015 Technique V
7 Levy et al. Advances in Posterior Cruciate Ligament Reconstruction 2015 Book chapter V
8 Engasser et al. All-Inside Posterior Cruciate Ligament Reconstruction 2015 Book chapter V
9 Hoogeslag et al. Double-Bundle, All-Inside Posterior Cruciate Ligament Reconstruction: A Technique Using 2 Separate Autologous Grafts 2016 Technique V
10 Vasdev et al. Arthroscopic All-Inside Posterior Cruciate Ligament Reconstruction: Overcoming the “Killer Turn” 2016 Technique V
11 Yasen et al. Transmedial All-inside TriLink Posterior Cruciate Ligament Reconstruction 2017 Technique V
12 Freychet et al. All-inside Posterior Cruciate Ligament Reconstruction Surgical Technique and Outcome 2019 Case series IV
13 Martin et al. Posterior Cruciate Ligament All-Inside Reconstruction 2020 Review V
14 Waly and Gawish Outcomes of the All Inside Single Bundle Posterior Cruciate Ligament Reconstruction Using Quadrupled Semitendinosus Tendon Graft 2020 Case series IV
3.1

3.1 Graft characteristics

9 studies preferred an allograft, 3 studies preferred an autograft and one study chose the graft type according to the surgical requirement. The preferred autograft is the semitendinosus and was used either in isolation or combined with gracilis or the contralateral semitendinosus as described by Hoogeslag.14 Bait et al.15 routinely utilized the semitendinosus (autograft) but preferred an allograft in a multiple ligament reconstruction.

The graft configuration varies amongst the studies and include double folded, tripled folded, Tri-Link and quadruple folded (graft configuration illustrated in Fig. 3). Amongst the 3 studies that reported using the Tri-Link method, Nancoo16 indicated its use when there is rotational instability. Of the other 11 studies that reported using quadruple folded grafts, 3 also utilized the triple fold when indicated. A summary of the above information is displayed in Table 2.

Illustration of Graft Double/Triple/Quadruple Fold (Left) vs. Tri-Link method (Right).
Fig. 3 Illustration of Graft Double/Triple/Quadruple Fold (Left) vs. Tri-Link method (Right).
Table 2 Choice of graft, graft Configuration.
Choice of Graft n (%)
Autograft 4 (29%)
Allograft 9 (64%)
No preference 1 (7%)
Graft configuration
Triple Fold 8 (57%)
Quadruple Fold 1 (7%)
Tri-link 2 (14%)
Triple Fold/Tri-Link 1 (7%)
Quadruple Fold/Tri-link 2 (14%)

11 studies reported graft diameters ranging from 8 to 12 mm. The reported graft length in 12 studies ranged from 60 to 150 mm. One of the remaining 2 studies proposed calculating the graft length according to the graft length intended for the femoral and tibial sockets (Illustrated in Fig. 4).

Range of femur and tibia socket lengths (Left), graft diameter (Middle), graft length (Right).
Fig. 4 Range of femur and tibia socket lengths (Left), graft diameter (Middle), graft length (Right).
3.2

3.2 Socket lengths

The reported femur socket lengths ranged from 15 to 35 mm. The preferred tibia socket lengths ranged generally from 20 to 45 mm, although Slullitel et al. reported lengths of up to 70 mm (Illustrated in Fig. 4.)

3.3

3.3 Portals used

The highest number of portals used were 6, and the minimal number of portals used were 3. The 3 commonly used portals were anterolateral (AL), anteromedial (AM) and posteromedial (PM) as well as variations of these anatomical locations. 3 studies specified the use of high AL and low PM portals. 3 studies included the use of the superomedial (SM) portal. Levy described the use 6 portals, which included the superomedial, inferomedial, accessory inferomedial, inferolateral as well as accessory posteromedial portal.17 The use of a posterolateral portal was not reported. 7 studies reported graft entry via the anteromedial portal and 6 studies utilized a lateral portal (2 low AL portal, 2 accessory inferolateral (IL) portal, 1 accessory AL portal and 1 low accessory AL portal) for similar purpose. In the afore mentioned 13 studies, graft entry was with the tibia end first. Vasdev et al. used the PM portal for graft entry and docking the femoral end of graft first.18 The above information is summarized in Table 3 below.

Table 3 Number of portals used, Types of portals used, Portal used for graft entry.
Number of Portals used n (%)
3 Portals 9 (64%)
4 Portals 2 (14%)
5 Portals 2 (14%)
6 Portals 1 (7%)
Types of Portals used
Accessory Portala 5 (36%)
Inferolateral 1 (7%)
Inferomedial 1 (7%)
Superomedial 3 (21%)
Posteromedial 13 (93%)
Anterolateral 13 (93%)
Anteromedial 13 (93%)
Portal used for Graft Entry
Anteromedial Portal 7 (50%)
Lateral Portal 6 (43%)
Posteromedial Portal 1 (7%)
Site of Accessory Portal detailed in Appendix Table 1.
3.4

3.4 Augmentation and fluoroscopy

9 studies used augmentation in their surgical technique. 6 studies used suture anchors to increase fixation stability of the tibia sutures of the graft and 3 studies used suture tape as internal brace. 8 studies reported the use of 30° and 70° arthroscopes. The use of fluoroscopy was reported in 10 studies for purposes such as correct placement of the PCL guide, guidewire and tibial tunnel placement (Summarized in Table 4.)

Table 4 Arthroscope lens used, Use of Augmentation, Use of Fluoroscopy.
Arthroscope lens used n (%)
Not Mentioned 6 (43%)
30, 70 8 (57%)
Use of Augmentation
Not Mentioned 5 (36%)
Tibia Anchor 5 (36%)
Tibia Anchor/Screw Post 1 (7%)
Internal Bracing 3 (21%)
Use of Fluoroscopy
Not Mentioned 4 (29%)
Yes 10 (71%)
3.5

3.5 The author’s preferred surgical technique

The current technique is described in a left knee with an isolated PCL tear. The patient is supine and placed under general anaesthesia. An examination under anaesthesia is performed. Knee hyper-extension or rotational laxity (in comparison with the contralateral knee) is specifically looked for. A calf pump is applied to the contralateral leg. A tourniquet of appropriate size is applied onto the proximal thigh and the patient is cleaned and draped. A high anterolateral (AL) portal is made and an arthroscope with 30° lens is inserted. An anteromedial (AM) portal is subsequently made under direct visualization with the arthroscope. A diagnostic arthroscopy is performed and PCL injury is confirmed. The intra-articular pathologies involving cartilage and meniscus are addressed. A posteromedial (PM) portal is made under direct visualization with the scope inserted between the PCL and the lateral side of the medial femoral condyle. A radiofrequency wand (Werewolf Flow 50 Coblation wand, Smith & Nephew) is used interchangeably with a shaver (Dyonics 4.5 Incisor Plus Blade, Platinum series, Smith & Nephew) to release the midline septum and allow the posterior capsule as well as the neurovascular structures to retract posteriorly. Limited debridement is performed and the PCL remnant is preserved.

Graft preparation and arthroscopic preparation is then performed concurrently, with help of the surgical assistant. An allograft is the preferred choice and a minimum length of 300 mm is required. The graft is thawed, prepared and quadruple folded. A folded graft length of 70 mm is required to ensure at least 20 mm of graft in each socket. A graft diameter of at least 9 mm is desired. The femoral and tibia ends of the quadrupled graft are looped over an Ultrabutton (Andover, MA, USA, Smith & Nephew). Each graft end is sutured at 10 mm and 20 mm from its corresponding loop. An Ultratape (Memphis, TN, USA, Smith & Nephew) is threaded through the outer holes of the femoral and tibia Ultrabuttons with its free ends at the tibia end of the graft. After preparation, the graft construct is then soaked in vancomycin till it is deployed.

The PCL tibia guide is introduced via the AM portal, in between the ACL and PCL on the lateral side of the PCL remnant with visualization from the PM portal. The guide tip is seated 10 mm below the joint line. The guide bullet is positioned at the mid-point between the tibia crest and medial border, with the jig angulated at 60°. The entry of the guide pin is followed by the tibia reamer (Acufex Trunav retrograde drill system, Andover, MA, USA, Smith & Nephew) under direct visualization. The Reamer is deployed and a tibia socket of 30 mm length is reamed. The passing suture is then pulled out via the AL portal. This completes the preparation for the tibia socket.

The femoral jig is introduced via the AM portal and the ring centre is positioned over the centre of the PCL anterolateral bundle femoral footprint. The guide wire entry is made under direct visualization with the arthroscope in the AL portal. The radius of the chosen reamer is checked to ensure it will not disrupt the cartilage articular surface. This is followed by deployment of the retrograde reamer. A socket of 25 mm length is made. The passing suture is then pulled out via the AM portal, and transferred to the AL portal.

The passing suture for the femoral socket is then transferred to the AL portal. The femoral and tibia passing sutures are checked to ensure there is no soft tissue interposition or entanglement.

The graft construct is passed via the AL portal into the femoral socket with the scope located either in the AM, or high accessory AL portal. The femoral Ultrabutton is deployed and the femoral end of the graft is cinched into the socket. The tibia end of the graft construct is then pulled into the tibia socket via the AL portal until the tibia Ultrabutton is seen to exit onto the anteromedial tibia outer cortex. The arthroscope is now switched to the PM portal. The graft entry into the tibia socket is observed under direct visualization. The tibia Ultrabutton is deployed with the knee flexed at 90° and anterior drawer force applied. The knee is then cycled and additional femoral tensioning is applied accordingly under direct arthroscopic visualization. Following which, the knee is fully extended and the free ends of the suture tape are anchored onto the anteromedial tibia outer cortex distal to the tibia Ultrabutton with suture anchor(s) (Footprint Ultra PK 5.5 mm, Andover, MA, USA, Smith & Nephew). The PCL graft is probed and the reduction of ACL slack is noted. The wounds are closed and dressing applied. A cryocuff and Jackson knee brace is applied.

3.6

3.6 Rehabilitation

The inpatient stay is routinely less than 24-h, and the patient is discharged the following day after review by the surgical and physiotherapy team. For the first month, the patient is given instructions for non weight bearing, followed by partial then full weight bearing after another two weeks. However, passive range of motion of up to 90° is allowed during this period, with support from the Jackson brace which is advised to be kept on all round the clock. The initial rehabilitation focused on quadriceps strengthening and passive range of motion with the patient prone. After six weeks, full active range of motion and weight bearing as tolerated are allowed.

4

4 Discussion

In the current analysis, 9 studies reported allograft use, 4 studies used autograft and one study15 chose one or the other according to patient's condition (isolated versus multi-ligament knee injury). To meet the length required for this purpose, authors had described triple folding the graft to achieve the desired graft length. The graft diameter (maximum 9 mm) was smaller in the studies that utilized autograft and a shorter length was also reported (maximum of 90 mm). The studies that utilized allograft reported diameter of 12 mm and length of 150 mm after graft preparation. One of the challenges with the all-inside technique is the minimum length and size of the graft required to optimally reconstruct the PCL. Careful consideration must therefore be given in cases using this technique when an allograft is not readily available due to the limited length and thickness of an autograft. In cases with this limitation, the use of a new graft to augment the preserved native PCL remnant can further be explored as an alternative.

The semitendinosus is the autograft of choice compared to the gracilis, and some authors prefer combinations including both gracilis and semitendinosus, or bilateral semitendinosus.14 Though autograft preservation is a potential advantage for all-inside ACL reconstruction, this is less likely applicable in all-inside PCL reconstruction due to the requirement of a more robust graft. An autograft, depending on its source, might be adequate for an isolated PCL reconstruction but donor morbidity needs to be borne in mind when it is a MLKI. Though biomechanical studies have reported on improved knee stability with the use of autografts,19 the clinical outcome is still similar to allograft use. The use of quadriceps tendon was not observed in the current review. Good outcomes had been reported on the use of the quadriceps tendon for ACL reconstruction20 and similarly there are reports encouraging its use for PCL reconstruction.21 Given the size of the native PCL, appropriate choice of graft is important, to ensure adequate diameter and length to achieve a stable reconstruction. Furthermore, in the traditional PCL reconstruction, the longer graft is likely subjected to more creep and stress relaxation. These phenomena have lesser impact on a shorter all-inside PCL graft with larger diameter with additional stability from an internal brace. In addition to the above described considerations with regards to graft choice and configuration, practicing surgeons must also be mindful of the outcomes associated with the use of either autograft or allografts in PCL reconstruction.22

The global trend23 of remnant PCL removal is seen in 9 of the studies in the current review. The native PCL is relatively bigger24 and more vascular25 than the native ACL. The femoral footprint spans the mid-trochlea to the mid-notch point and the tibia footprint size has been proposed to be two-fifths the medial to lateral width of the interspinous distance and associated with anthropomorphic variables.26–28 The PCL remnant and its vasculature enhance graft remodeling,29,30 and the remnant-graft construct with its preserved footprints maintains the native PCL biological attachments and the tensioned graft restores its length. Furthermore, Song31 showed satisfactory outcome in graft augmentation of the PCL remnant despite heterogenous study parameters such as follow up period and graft types. The author's preference in our surgical technique is therefore to preserve the remnant PCL.

In the current review, fluoroscopy use was reported in 10 studies for siting the graft in anatomical position. The trade off with the use of fluoroscopy to accurately site the graft, and therefore maintain graft stability as graft remodeling takes place, is the exposure of the patient and the surgical team to radiation.32 Furthermore, positioning of the image intensifier machine over the operated limb is an additional step which introduces risk of contamination as well as lead to increased operative time. With the PM portal that offers direct visualization of the PCL tibial footprint and the surrounding operative field, the authors find that fluoroscopy is not necessary for guide wire insertion, tibia jig placement or reaming. Of note is that the reverse reamer moves away from the vital posterior neurovascular structures during reaming and mitigate the risk of their injury.

Augmentation of the reconstruction with implants was done in 9 studies, and is also preferred in our surgical technique. Suture anchors and an internal brace are both important adjuncts for graft stability. The internal brace is only anchored down after the tibia Ultrabutton is deployed, and the graft tensioned. This allows the internal brace to perform a key function of acting as a safety mechanism to prevent overstretching of the graft during the early stages of graft remodeling.33

The visualization of the posterior knee is challenging without a posterior portal. 9 studies utilized 3 portals such as the standard AL, AM and PM portals or variations of these portals. 8 studies reported the use of 30° as well as 70° arthroscopic lenses. The PM portal offers an adequate field of vision of the posterior knee anatomy to accurately site the tibia socket, retrieve the passing sutures and dock the graft into the socket. It reduces the need for a 70° lens. This obviates the need for user familiarity with the 70° lens and to interchange it with the 30° scope during the procedure. There is variation in the choice of portal for graft entry with 7 of 14 studies preferring an AM portal. Graft entry via the AM portal may be preferred due to the shorter graft passage from the portal to the femoral socket, and there is also good visualization of the passage with the scope at the AL portal. However, graft entry via the AM portal is at a more acute angle compared to entry via the AL portal. Alternatively, graft entry via the AL portal aligns more closely with the directional pull on the graft which facilitates its entry into the femoral socket. A consideration with this option however, is the need to view the graft passage with the AM or an additional high AL portal as a viewing portal.

When the graft is docked in the tibia socket first, a counter tension on the remaining graft is applied to enable deployment of the adjustable loop device on the medial outer cortex of the medial femoral condyle. The graft passage into the femoral socket first allows the application of counter tension in a straight line outside the portal and the deployment of the femoral Ultrabutton. Subsequently the tibia end of the graft is pulled into the tibia socket under direct vision (PM portal) and the tibia Ultrabutton is deployed. This obviates the need for intra-articular counter tension with an instrument.

Various technical variations exist in PCL reconstruction. The all-inside technique has been adapted for PCL reconstruction understandably, owing to the ongoing evolution and early favorable results3,34,35 in ACL reconstruction. There is limited literature on all-inside PCL reconstruction partly due to the low incidence8 of PCL injury, as well as selected36 PCL injuries for surgery such as a symptomatic tear, laxity of grade III or multi-ligament knee injury (MLKI). This paper provides a systematic review of the existing literature covering the All-Inside PCL Reconstruction surgical technique. The current review is limited by the quality of the evidence it summarized. It consisted of 9 technical articles out of 14. All included studies were given a ‘fair’ level of evidence. There were 2 case series with different study designs. The articles that are not peer reviewed or published were excluded and this subject this paper to publication bias. As most of the articles are technically orientated, the graft survivorship, complications and revision rate are not adequate for meta-analysis. Future research including clinical outcome studies, paying attention to compare the variables of each specific component involved in the surgery should be considered to determine the best practices possible.

To the author's best knowledge, this is the first paper observing the trends in current practice with detail of each individual component involved in the surgery. Our paper provides an update for optimal practices using the All-Inside PCL reconstruction technique for the practicing surgeon.

5

5 Conclusion

The current trend in clinical practice for the All-Inside PCL Reconstruction surgical technique involves the use of an allograft, a minimum of 3 portals, and docking the graft in the tibia socket first with no identified preference for the portal used for graft entry. The 70° arthroscopic lens, fluoroscopy, suture anchors and internal brace are often used to optimize surgical outcome.

This current review of the All-Inside PCL Reconstruction surgical technique consisted mainly of technical studies, and a limited number of clinical series. Clinical outcome studies comparing the variables of each specific component involved in the surgery are required to advance our knowledge and identify the best surgical practice possible.

Identifying information

There is no identifying information in the blinded manuscript.

Grant number

There was no grant involved for this paper.

Conflict of interest statement

There are no conflicts of interest.

Data availability statement

The data involved in the writing of this paper is available directly from the author.

Guardian/Patient's consent

Consent was not required for this paper.

Ethical statement

No ethical board approval was required for this paper.

Funding statement

There was no funding received for this paper.

CRediT authorship contribution statement

Jun Rui Don Koh: Conceptualization, Methodology, Formal analysis, Data curation, Writing – original draft, Visualization. Sir Young James Loh: Conceptualization, Methodology, Formal analysis, Data curation, Writing – review & editing, Visualization, Supervision.

References

  1. , , , . All-inside anterior cruciate ligament graft-link technique: second-generation, no-incision anterior cruciate ligament reconstruction. J Arthrosc Relat Surg. 2011;27(5):717-727.
    [Google Scholar]
  2. , , , , . Preoperative prediction of anterior cruciate ligament tibial footprint size by anthropometric variables. Knee Surg Sports Traumatol Arthrosc. 2017;25(5):1638-1645.
    [Google Scholar]
  3. , , , et al . All-inside anterior cruciate ligament reconstruction-A systematic review of techniques, outcomes, and complications. Knee Surg. 2018;31(9):895-904.
    [Google Scholar]
  4. , , , . Minimum 10-year follow-up of patients after an acute, isolated posterior cruciate ligament injury treated nonoperatively. Am J Sports Med. 2013;41(7):1526-1533.
    [Google Scholar]
  5. , , , . A systematic review of evidence for anterior cruciate ligament rehabilitation: how much and what type? Phys Ther Sport. 2004;5(3):125-145.
    [Google Scholar]
  6. , , , , , , . Epidemiology of surgically treated posterior cruciate ligament injuries in Scandinavia. Knee Surg Sports Traumatol Arthrosc. 2017;25(8):2384-2391.
    [Google Scholar]
  7. , , , . History of the "All-Inside" technique and its clinical application. J Orthop. 2011;3(2):81-86.
    [Google Scholar]
  8. , , , , , . Epidemiology of posterior cruciate ligament injuries. Arch Orthop Trauma Surg. 2003;123(4):186-191.
    [Google Scholar]
  9. , , . Long-term results of nonoperative treatment of isolated posterior cruciate ligament injuries in the athlete. Am J Sports Med. 1986;14(1):35-38.
    [Google Scholar]
  10. , . An increasing trend of posterior cruciate ligament reconstruction in South Korea: epidemiologic analysis using Korean National Health Insurance System Database. Knee surg Relat Res. 2021;33(1):44.
    [Google Scholar]
  11. , , , et al . The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021;372
    [Google Scholar]
  12. , , , , . Chapter 4: systematic reviews of text and opinion. 2020
    [Google Scholar]
  13. , , , et al . Methodological quality of case series studies: an introduction to the JBI critical appraisal tool. JBI Evid Synth. 2020;18(10):2127-2133.
    [Google Scholar]
  14. , , , , . Double-bundle, all-inside posterior cruciate ligament reconstruction: a technique using 2 separate autologous grafts. J Arthrosc Relat Surg. 2016;5(5):e1095-e1103.
    [Google Scholar]
  15. , , , , , , . Posterior cruciate ligament reconstruction with "all-inside" technique: a technical note. Muscles, ligaments tendons J, ligaments and tendons journal. 2015;4(4):467-470.
    [Google Scholar]
  16. , , , , , , . TransMedial all-inside posterior cruciate ligament reconstruction using a reinforced tibial inlay graft. J Arthrosc Relat Surg. 2013;2(4):e381-e388.
    [Google Scholar]
  17. , , , , . Advances in posterior cruciate ligament reconstruction. Instr Course Lect. 2015;64:543-554.
    [Google Scholar]
  18. , , , , , . Arthroscopic all-inside posterior cruciate ligament reconstruction: overcoming the "killer turn" J Arthrosc Relat Surg. 2016;5(3):e501-e506.
    [Google Scholar]
  19. , , , et al . Influence of graft source on postoperative activity and joint laxity in posterior cruciate ligament reconstruction: a systematic review. J Arthrosc Relat Surg. 2019;35(1):262-274.
    [Google Scholar]
  20. , , , , , , . Anterior cruciate ligament reconstruction: a systematic review and meta-analysis of outcomes for quadriceps tendon autograft versus bone-patellar tendon-bone and hamstring-tendon autografts. Am J Sports Med. 2019;47(14):3531-3540.
    [Google Scholar]
  21. , , , , , . The quadriceps tendon autograft is an option for primary PCL reconstruction: a systematic review. J ISAKOS. 2022;7(1):27-34.
    [Google Scholar]
  22. , , , , . Autograft versus allograft for posterior cruciate ligament reconstruction: an updated systematic review and meta-analysis. Am J Sports Med. 2018;46(7):1752-1757.
    [Google Scholar]
  23. , , , et al . Global variation in isolated posterior cruciate ligament reconstruction. J Exp Orthop. 2022;9(1):104.
    [Google Scholar]
  24. , , , . Posterior cruciate ligament: anatomy and biomechanics. Curr Rev Musculoskelet Med. 2018;11(3):510-514.
    [Google Scholar]
  25. , . Vascular anatomy of the human cruciate ligaments and surrounding structures. Clin Anat. 1997;10(3):151-162.
    [Google Scholar]
  26. , , , et al . Morphology of anterior cruciate ligament attachments for anatomic reconstruction: a cadaveric dissection and radiographic study. J Arthrosc Relat Surg. 2006;22(9):984-992.
    [Google Scholar]
  27. , , , . Anterior cruciate ligament tibial footprint anatomy: systematic review of the 21st century literature. J Arthrosc Relat Surg. 2012;28(5):728-734.
    [Google Scholar]
  28. , , , , , . Epidemiology of posterior cruciate ligament injuries. Arch Orthop Trauma Surg. 2003;123(4):186-191.
    [Google Scholar]
  29. , , , , , , . Healing potential of the transected posterior cruciate ligament of the rabbit. J Korean Orthop Assoc. 2001 Feb;36(1):25-32.
    [Google Scholar]
  30. , , , , , . Remnant preservation is helpful to obtain good clinical results in posterior cruciate ligament reconstruction: comparison of clinical results of three techniques. Clin Orthop Surg. 2013;5(4):278-286.
    [Google Scholar]
  31. , , , et al . Clinical outcome of posterior cruciate ligament reconstruction with and without remnant preservation. J Arthrosc Relat Surg. 2015;31(9):1796-1806.
    [Google Scholar]
  32. , , , , . Radiation risk from fluoroscopically-assisted anterior cruciate ligament reconstruction. Ann R Coll Surg Engl. 2010;92(4):330-334.
    [Google Scholar]
  33. , , , et al . Posterior cruciate ligament reconstruction with independent internal brace reinforcement: surgical technique and clinical outcomes with a minimum two year follow-up. Int Orthop. 2022;46(9):2019-2028.
    [Google Scholar]
  34. , , , . All-inside ACL reconstruction: how does it compare to standard ACL reconstruction techniques? J Orthop. 2017;14(2):241-246.
    [Google Scholar]
  35. , , , et al . Randomized controlled trial of all-inside and standard single-bundle anterior cruciate ligament reconstruction with functional, MRI-based graft maturity and patient-reported outcome measures. BMC Musculoskelet Disord. 2022;23(1):289.
    [Google Scholar]
  36. , , , , . Surgical management of PCL injuries: indications, techniques, and outcomes. Curr Rev Musculoskelet Med. 2013;6(2):115-123.
    [Google Scholar]