Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical research study
Current Issue
Editorial Board
Literature Review
Narrative review
Original Article
Research Article
Review Article
Short Report
Surgical techniques
Systematic Review and Meta-Analysis
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical research study
Current Issue
Editorial Board
Literature Review
Narrative review
Original Article
Research Article
Review Article
Short Report
Surgical techniques
Systematic Review and Meta-Analysis
View/Download PDF
72 (); 220-226
doi:
10.1016/j.jor.2025.10.025

Translate:

A systematic review examining the clinical evidence for the elbow internal joint stabilizer and associated complications

Author affiliations
McMaster University, Hamilton, Ontario, Canada
Hospital del Trabajador, Santiago, Chile
Universidad Andrés Bello, Chile
New Jahra Hospital, Al Jahra, Kuwait
AlRazi Orthopedic Hospital, Kuwait City, Kuwait
Orthopaedic Surgery Department. Pontificia Universidad Católica de Chile, Santiago, Chile
Orthopedic Surgery Department, Hospital Dra. Eloísa Díaz, La Florida, Chile
Article History
Corresponding author(s)

⁎Corresponding author: Preksha Rathod. preksha.rathod@medportal.ca

Article tools · PDF & citations

Abstract

Abstract

Elbow instability continues to be a challenging entity to manage in orthopedics due to the complex anatomy of the elbow joint. Historically, common management techniques involved ulnohumeral cross pinning, spanning plates or external fixation which can lead to complications such as infection, joint incongruity, or stiffness amongst others. More recently, an internal stabilizer has been introduced to allow early elbow range of motion while stabilizing the elbow. Our review aims to examine the literature pertaining to the internal joint stabilizer (IJS) with a focus on its safety profile and outcomes.

A systematic review of studies published in MEDLINE, EMBASE, Web of Science and Cumulative Index to Nursing and Allied Health literature (CINAHL) was conducted to assess the operative outcomes of the IJS. Data on patient demographics, indications for use, postoperative outcomes, complications, and implant removal were compiled.

Nine retrospective studies met the inclusion criteria. 246 patients with a mean age of 47.2 years were included in the analysis of acute and chronic cases of instability. There were 178 cases of acute instability and 64 cases of chronic instability. The mean follow up time was 17.5 months. The average outcome measures were DASH of 23.7 and MEPS of 83.3. Predominant complications included hardware-related complications (18.7 %, n = 46), heterotopic ossification (9.6 %, n = 24), and ulnar or median nerve-related symptoms (6.9 %, n = 17) which led to an average complication rate of 33.7 % and a 18.3 % reoperation rate. The average time to removal was 11.8 weeks with 75 % of patients having implant removal.

The IJS shows potential for treating elbow instability but does have limitations like high reoperation rates, hardware complications, and large cost which limit is routine use. Further research is needed to better understand its role.

Keywords

  • Internal joint stabilizer
  • Elbow instability
  • Terrible triad injuries
  • Elbow dislocation
  • Hinged external fixator
  • Internal stabilization
Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

The elbow comprises intricate bony and ligamentous elements that play a role to keep the joint stable. When these structures are compromised due to trauma, elbow instability can develop.1–3 Managing elbow instability poses a set of unique challenges, as treatment strategies range from conservative measures such as physical therapy to surgical intervention depending on the chronicity, severity and nature of the instability.4,5 To achieve satisfactory results, interventions should provide a stable elbow and allow for early range of motion (ROM) to avoid the problems associated with elbow immobilization.

Surgical interventions to treat elbow instability commonly include ligamentous repair or reconstruction, bony fixation, arthroplasty, or, oftentimes, a combination.4,6 In certain cases of complex elbow trauma, it is not unusual that internal fixation is unable to provide a stable joint making external fixation the preferred adjunct treatment. This can be done through static or dynamic external fixators (ExFix) to allow soft tissue and bony injuries to heal and, in the case of dynamic fixators, adding the theoretical advantage of allowing early ROM and therefore decreasing the chance of developing elbow stiffness.6–10 However, a dynamic ExFix is challenging to apply, and availability is limited. A static ExFix is more common but can be associated with pin tract infection, hardware failure and/or joint incongruency due to incorrect pin axis placement, and nerve injury amongst other complications.6,11–14 Another option to achieve stability is to apply a ulnohumeral joint cross-pinning, which is also limited by articular cartilage damage and concern for pin breakage.15 Lastly, temporary elbow arthrodesis plates are an alternative that are useful in settings of poor bone quality, low fracture line, severe comminution, or revision cases. However, the use of this plate subjects patients to lifelong activity and weightbearing restrictions, as well as risk of implant loosening or periprosthetic fracture.16

An internal stabilizer in the form of a Steinmann pin through the axis of ulnohumeral rotation was initially used by Orbay et al., in 2014 as a stabilizing alternative to a hinged ExFix for complex elbow instability.17 This subsequently led to the development of a commercial hinged Internal Joint Stabilizer (IJS) device that acts as a temporary stabilizer. This device, which intends to work as an internal dynamic fixator, has piqued interest due to its potential advantages of allowing early ROM while solving cases of persistent instability intraoperatively. However, there is limited evidence regarding its use and safety profile. Therefore, this study aims to examine the existing literature that investigates the clinical application of the IJS in both acute and chronic cases of elbow instability.

2

2 Methods

This systematic review was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines it was prospectively registered with PROSPERO (International Prospective Register of Systematic Reviews) (ID: CRD42023402983).

2.1

2.1 Search strategy

A systematic search of Medline, Embase, Web of Science and CINAHL (Cumulative Index to Nursing and Allied Health Literature) databases was performed using the following key words: ((Internal joint stabilizer) OR (Internal Joint stabilizer)) AND (Elbow). This search strategy aimed to increase the incorporation of relevant articles while reducing the inclusion of studies focusing on alternative stabilization methods. Articles published on or prior to August 1, 2025 were considered for inclusion.

2.2

2.2 Eligibility criteria

Studies meeting the following criteria were included: (1) Articles reporting the use of an IJS for surgical management of acute or chronic elbow instability; (2) Studies reporting outcomes of at least 5 patients; (3) English, Spanish, or Arabic studies. Studies with the following characteristics were excluded; (1) biomechanical or cadaveric studies; (2) review articles; (3) studies whose full text were not available; (4) studies using alternative forms of IJS varying from the commercial device.

2.3

2.3 Study screening

Titles and abstracts were screened by two independent reviewers (D.M. and K.A.) using Covidence (Covidence systematic review software, Veritas Health Innovation, Melbourne, Australia, www.covidence.org). Articles meeting the initial screening criteria underwent full text screening to identify relevant articles. Any conflicts were resolved by a third reviewer (P.R.).

2.4

2.4 Quality assessment

Study quality assessment was conducted using the methodological index for non-randomized studies (MINORS) criteria. The MINORS checklist comprises 12 items, with a scoring range of up to 16 for non-comparative studies and 24 for comparative studies. Methodological quality was classified as follows: a score falling within 0–8 or 0–12 was deemed poor quality, while scores in the range of 9–12 or 13–18 were considered fair quality. For non-comparative and comparative studies, respectively, scores ranging from 13 to 16 or 19–24 were categorized as excellent quality.

2.5

2.5 Data extraction

Two authors (D.M and K.A) independently extracted pertinent information from the included studies and entered it into a Microsoft Excel spreadsheet (Microsoft, Redmond, Washington, USA). This data included general details about the articles (such as title, author, publication date, journal, and country of origin), sample data, and methodological particulars (including study design, sample size, and inclusion/exclusion criteria). Additionally, details about patient demographics and surgical procedures (such as age, gender, diagnoses, and cause of instability) were collected, along with relevant outcome measures (follow-up period, patient-reported outcome scores, range of motion, complications, and revision surgery).

The scoring systems employed in the analysis included the Disabilities of the Arm, Shoulder, and Hand (DASH), quick DASH (Q-DASH), Broberg-Morey Score, Patient Rated Elbow Evaluation (PREE) and the Mayo Elbow Performance Score (MEPS).

2.6

2.6 Data analysis

Descriptive statistics including the mean, range and measures of variance (e.g. standard deviations, 95 % confidence intervals [CI]) were utilized where applicable. Data were synthesized into pooled demographics, treatment, and outcome measures. Due to the heterogeneity of the included outcome measures, subgroup analysis was not possible. Measures of spread were calculated from each study if individual data were reported.

3

3 Results

After removal of duplicates, 889 studies were included in the initial screening. There were 869 studies that did not meet the inclusion criteria therefore 20 studies underwent full text review. Of the 14 studies considered for data extraction, 3 were excluded because they utilized alternative methods for construction of the IJS which differed from the original device to be assessed. These studies commonly utilized a Steinnman Pin or K-wire to construct an internal stabilizer along the axis of ulnohumeral rotation. 11 studies were included in the final data analysis (Fig. 1).

PRISMA flow diagram summarizing the study selection process.
Fig. 1 PRISMA flow diagram summarizing the study selection process.
3.1

3.1 Study data

The study design and demographics are detailed in Table 1. All included studies were retrospective in nature. The total number of patients included were 246 with a mean age of 47.2 years. There was a predominance of male patients (n = 167, 67.9 %). The mean MINORS score was 10 which indicates moderate quality evidence. The IJS was used mostly in cases of acute instability (n = 178, 73.5 %), particularly for terrible triad injuries (52.3 %) as outlined in Table 218–28 The average time of follow up was 17.5 months.

Table 1 Study designs and demographic information of included studies.
Study Country Study Type MINORS Sample Size (N) Female, N (%) Age, mean Acute Cases Chronic Cases
Orbay 2017 USA Cohort 10 26 14 (54) 57 19 7
Sochol 2019 USA Case Series 9 20 7 (35) 48.8 9 11
Pasternack 2020 USA Case series 10 10 6 (60) 50.8 9 1
Pardo-Garcia 2021 Spain Case Series 8 5 1 (20) 37.4 5 0
Salazar 2022 USA Cohort 10 22 10 (45.4) 46 20 1
Fene 2022 USA Case Series 9 20 8 (40) 41 13 4
London 2023 USA Cohort 11 29 NR 50.7 29 0
Wynn 2023 USA Cohort 11 12 6 (50) 52 12 0
Sheth 2023 USA Cohort 10 30 7 (23) 43 25 5
Crescenzo 2024 Italy Case Series 11 16 5 (31) 45.1 5 11
Heifner 2024 USA Case Series 10 56 15 (27) NR 32 24
Pooled Data 246 79 (32.1) a 47.2 b 178 64
With data from London 2023 removed.
With data from Heifner 2025 removed.
Table 2 Indications for the use of IJS.
Acute Chronic
Fracture-Dislocations Dislocation Fracture Dislocation Instability
Terrible Triad Monteggia Other
Orbay 2017 12 1 5 1 6 1
Sochol 2019 8 1 11
Pasternack 2020 6 2 1 1
Pardo-Garcia 2021 5
Salazar 2022 8 9 1 2 1
Fene 2022 7 5 1 2 2
London 2023 29
Sheth 2023 20 5 5
Wynn 2023 12a
Crescenzo 2024 3 1 1 11
Heifner 2024 32a 24a
Did not specify injury type for acute or chronic subgroup.
3.2

3.2 Outcomes

The mean removal time of the IJS was 15.9 weeks. 44 (17.8 %) patients did not have the IJS removed due to various reasons including patients lost to follow up, patients not interested in further surgery, or its removal was not routinely offered by the authors. The patient reported outcome measures (PROMs) are displayed in Table 3. The mean DASH score was the most commonly reported measure with ten studies reporting a pooled mean score of 23.718−21, 23-28. This was followed by the MEPS score reported in six studies with a mean of 83.319,21,25-28. Overall, the PROMs indicated favorable results. The post-operative protocol for ten of eleven studies included early ROM within two weeks post-operative from IJS implantation; there was one study that did not report its post-operative protocol.18–28 Final ROM data demonstrated a mean flexion-extension arc of 110° and pronation-supination arc of 147°18-28.

Table 3 Patient Reported Outcome Measures (PROMs), postoperative protocol, and postoperative functional outcomes of the IJS.
Study PROMs Mean ± SD (Range) Post-op Flex/Ex Arc° MEAN Post-op Sup/Pro Arc° MEAN Early ROM Post-Op (Y/N)a MEAN time to IJS removal WEEKS (range)
Orbay 2017 DASH 16 ± 18 (0–68) Broberg Morey 93 ± 5.4 119 151 Y 7 (6–8)
Sochol 2019 DASH 37.3 ± 29.3 MEPS 82.5 ± 14.3 124.3 NR Y NR
Pasternack 2020 DASH 28.7 ± 19.2 Broberg Morey 68.2 ± 25.4 106 141 Y 8 (6–10)
Pardo-Garcia 2021 DASH 11.8 (4.2–20.6) MEPS 94 (85–100) 122 160 Y 14 (12–16)
Salazar 2022 NR 101.4 154 Y 19 (0–41)
Fene 2022 DASH 28.4 ± 23.2 (7.5–84.2) 92 139 Y 16 (8–24)
London 2023 qDASH 30.3 ± 5.3 PREE 35.8 ± 5.9 115b 140b NR NR
Wynn 2023 DASH 12 (8–34) MEPS 78 (65–95) 105 160 Y NR
Sheth 2023 qDASH 24 ± 19 MEPS 74 ± 18 100 122 Y 7 (4–10)
Crescenzo 2024 DASH 26.3 ± 5.3 MEPS 90.3 ± 6 123 150 Y 31 (16–56)
Heifner 2024 DASH 22 (NR) MEPS 81 (NR) 110 NR Y 24.9 (3–232c)
Early ROM defined as within 2 weeks.
Median.
Outlier that was removed from mean calculation.
3.3

3.3 Complications

The complications resulting from the IJS are outlined in Table 4. The average complication rate was 33.7 % (n = 83). The most prevalent complication was hardware complication (n = 46, 18.7 %), heterotopic ossification (n = 24, 9.6 %), followed by median or ulnar nerve injury (n = 17, 6.9 %). Persistent instability was amongst the lowest reported complications (n = 8, 3.3 %).18–28

Table 4 – Complications after the use of the IJS.
Study Complication, N patients (%) Heterotopic Ossification Nerve Symptoms Infection Contracture Stiffness Persistent Instability Wound Problems IJS Hardware related complications
Orbay 2017 4 (16.6) 2 1 1 1 1 inflammatory reaction to implant
Sochol 2019 6 (30) 4 4 1 4 1 broken implant component
4 prominent hardware
Pasternack 2020 4 (40) 1 1 2 1 None reported
Pardo-Garcia 2021 2 (40) 1 1 None reported
Salazar 2022 10 (45.4) 3 3 3 1 loosening of axis pin
2 uncoupling at proximal locking joint
Fene 2022 5 (25) 1 1 1 1 uncoupling of proximal locking joint
1 axis pin loosening
London 2023 19 (65.5) 10 6 5 6 3 5 axis pin lucency
2 broken base plate
1 IJS dissociation
Wynn 2023 4 (33.3) 2 2 symptomatic implant
Sheth 2023 8 (26) 3 1 4 uncoupling at proximal locking joint
8 axis pin lucency
Crescenzo 2024 10 (62.5) 5 3 Uncoupling at proximal locking joint
4 Axis pin loosening
Heifner 2024 11 (19.6) 2 3 5 Dissociation of proximal locking joint
1 Axis pin loosening
Totals 83 (33.7) 24 (9.6) 17 (6.9) 13 (5.3) 11 (4.5) 8 (3.3) 8 (3.3) 3 (1.2) 46 (18.7)
N, (%)

Of the 33 IJS-related hardware complications (Table 4). Radiographic axis pin lucency was the most common (n = 19, 7.7 %) followed by uncoupling at the proximal locking joint (n = 5, 6.1 %). Other hardware-related issues included prominent hardware, broken baseplate, and symptomatic implant.18–28

3.4

3.4 Implant removal and Re-operations

Implants were routinely removed in nine of the eleven studies (77.8 %), though only eight reported time to implant removal.18,20–23,26–28 The average time to implant removal was 15.9 weeks. Table 5 shows that the overall reoperation rate was 18.3 % with the reasons for re-operation being IJS-related hardware complications (n = 17), contracture release (n = 10), followed by infection, heterotopic ossification resection, and nerve surgery (n = 5 each).18–28

Table 5 – The Rate and Type of Reoperation after the use of the IJS.
Study Reoperation Rate % (N) Revision of IJS % (N) Removal of IJS % (N) Nerve Transposition and/or decompression % (N) Contracture Release % (N) Heterotopic Ossification Resection % (N) I&D for Infection % (N) Other % (N)
Orbay 2017 0 NR
Sochol 2019 27 (1) (1)
Pasternack 2020 40 (1) (2) (1) 1 total elbow for post-traumatic arthritis
1 MCL reconstruction
Pardo-Garcia 2021 0 NR
Salazar 2022 14 (2) (1) 1 ExFix application
Fene 2022 12 (2)
London 2023 41 (3) (4) (5) (4) (3)
Wynn 2023 17 (2)
Sheth 2023 66 (4) (3)
Crescenzo 2024 0
Heifner 2024 5.3 (3)
18.3 (45) 20 (9) 17.8 (8) 11.1 (5) 22.2 (10) 11.1 (5) 11.1 (5) 6.7 (3)
4

4 Discussion

Treating acute and chronic elbow instability can be a significant challenge in orthopedics as each poses a unique set of challenges. The complexity of the bony and soft tissue structures of the elbow joint adds difficulty in devising effective therapeutic strategies. Regardless of the chronicity, the optimal treatment should balance the need for stability with preservation of joint function and early ROM. This can become particularly challenging in acute cases of severe trauma where stability may be compromised for joint function, and vice versa. External fixation is occasionally needed as an adjunct in these situations. A retrospective study by Deemer et al. of acute elbow fracture/fracture-dislocations showed a rate of 7 % (26 of 391 cases) which required application of an ExFix.29 While a viable option, complication rates ranging from 26 % to 57 % limit its use.13,15,30

An early study by Orbay et al., in 2014 where an internal stabilizer was constructed using a Steinnman pin showed promising results by stabilizing the elbow while also allowing early ROM to aid the surgical community when dealing with persistent elbow instability despite attempting a comprehensive treatment of elbow injuries.17 This led to the development of a commercially available, temporary IJS device (Skeletal Dynamics). Research investigating the use of the IJS has demonstrated positive outcomes thus far as it mitigates many of the complications associated with external fixators. However, the indications, safety profile, and outcomes associated with the device are not well-outlined.

In this review, 82.5 % of the cases where the IJS was used involved acute elbow traumatic injuries, mainly terrible triad cases. A terrible triad injury is especially concerning due to the high instability it causes and lack of early ROM, leading to a poor prognosis.31 Ostergaard et al. have reported a re-operation rate as high as 47 % associated with terrible triad injuries.32 A systematic review by Chen et al. of 312 patients found that this ranged from 0 to 54.5 %, and the majority of studies reported a ∼30 % reoperation rate. The reasons for reoperation are multifactorial including ulnar neuropathy, heterotopic ossification, arthrosis, and infection.33 Our review outlines that the combined reoperation rate with the IJS was 24 %. Unfortunately, the reporting of most studies did not specify whether this rate was for patients with acute or chronic injuries. There is currently no agreement on whether the IJS is more effective in cases of acute or chronic instability.

The device was associated with achieving functional postoperative ROM. As mentioned, final ROM data demonstrated a mean flexion-extension arc of 110° and pronation-supination arc of 147°. The functional ROM in adults for most activities of living has been established as 30°-130° of flexion-extension, which equals a 100° arc, and 50° of protonation and supination.34 The IJS restored this functional ROM in 75 % of patients. A contributor to this outcome could be that most studies started ROM training early in the post-operative protocol. Nevertheless, at the final follow up, 25 % of patients exhibited a flexion-extension arc of less than 100°, indicating that a considerable portion still experienced persistent stiffness after treatment. This finding is important to highlight as this device has been proposed to allow early ROM with the alleged benefit of improving patient outcomes. Our review results indicate surgeons should be cautious when advising their patients about the potential benefit of achieving better ROM when using this device.

The major complications associated with the IJS implantation were heterotopic ossification and hardware complications. The device failure was through three main mechanisms: axis pin loosening, uncoupling of the device at the proximal locking joint, and broken baseplate component. Thus, surgeons applying the device should pay particular attention to these components at initial implantation and subsequent follow-up radiographs. The studies documenting radiographic axis pin loosening as a complication did not establish a clear distinction between ‘normal’ versus ‘abnormal’ lucency, as some level of lucency is expected with pin placement. Consequently, it remains uncertain whether there is a consensus amongst these studies regarding what constitutes abnormal lucency. Remarkably, recurrent instability had a low complication rate of 3.3 %. A review by Heifner et al. determined that the rate of recurrent instability with external fixation was 7 %.35

The IJS poses as a promising treatment for elbow instability, however there are notable concerns with the device. This is supported by the evidence that while the overall PROMs showed good functional outcomes and patient satisfaction, the overall complication rate was 33.7 %, the overall re-operation rate was 18.3 %, and while 75 % of patients achieved functional ROM, 25 % did not. Therefore, we believe that while the IJS can be a useful adjunct in the treatment of complex elbow instability, it should be used with caution given high rates of complications and revision surgeries, and large proportion of patients with some degree of stiffness (unable to achieve functional ROM).

In addition, the IJS is designed as a temporary device, and it is recommended that it be removed approximately 3–4 months after implantation. Though all studies but one routinely removed the IJS, the average time to removal had notable variations.28 These variations may have influenced functional outcomes and complications to some degree.

This systematic review does have several limitations. Particularly, it is limited by the quality of the included studies. The mean MINORS score was 10 supporting the moderate quality of the evidence. Furthermore, all studies were retrospective in nature which further supports that the strength of the evidence is not of the highest quality. There was only one study directly comparing the use of the IJS to an alternative treatment.25 Secondly, there was a limited sample size and the mean follow up time for the included studies in this review was 17.5 months. Data from a larger prospective cohort with longer follow-up periods would provide more robust and meaningful results. However, this may be difficult to achieve given the relative low incidence of these injuries and the variety in their nature.36–38 Additionally, the studies lacked homogeneity in a few aspects. The type of injury, surgical approaches, surgeon threshold to apply the device, and post-operative management varied between studies which makes drawing firm conclusions challenging. Lastly, the authors acknowledge the existence of a prior meta-analysis on the subject, nonetheless there are differences in the conclusions drawn. The previously published paper by Heifner et al. reported low device failure and low recurrent instability rates for the IJS.39 Our review supports the low rate of recurrent instability (3.3 %). However, we report a higher incidence of complications such as hardware related complications, heterotopic ossification, nerve injury, and stiffness not previously reported underscoring the importance of assessing these risks, cost, and associated procedures before considering IJS application. This systematic review offers value to existing literature by providing a comprehensive review of the outcomes, complications, and re-operations associated with the IJS, while also offering insight into the drawbacks precluding its routine use.

Another limitation of this review is that the studies included omitted routine reporting of outcomes and complications separately for acute and chronic cases of instability, which has limited the separate analysis of outcomes. This differentiation is crucial essential for defining the optimal clinical context for the IJS. Further investigation into the utility of the device in chronic versus acute instability may help further delineate specific indications for IJS use. Future directions should also focus on larger comparative studies between the IJS and alternative fixation methods such as external fixation, internal fixation with spanning plate, or ulnohumeral joint cross-pinning. Considering the difficulties in conducting higher quality studies due to the infrequent occurrence of injuries necessitating the IJS, leveraging data from surgical registries could be a valuable approach to answer additional questions. Additionally, the high device failure rate may highlight a potential need to improve implantation techniques and consider device manufacturing modifications. Efforts can also be made to provide surgeons with specialized training in IJS implantation to decrease complication rates. Lastly, a major barrier to widespread use of the IJS is the cost of the implant. Wynn et al. examined the cost analysis between a static ExFix and the IJS showing that while the cost of the IJS is higher, the cost associated with adjunct resources used for application of the ExFix were higher.25 Further studies analyzing the implant and institution expenses for common devices used to treat elbow instability (ie. ExFix, ulnohumeral cross-pinning, IJS, and temporary elbow arthrodesis plates) will be crucial for surgeon decision-making when treating elbow instability.

5

5 Conclusions

The current literature demonstrates that the IJS is a comparable alternative to external fixation or ulnohumeral joint cross-pinning in the treatment of acute and chronic elbow instability. However, a high reoperation rate and hardware related complications may limit its use clinically and caution is warranted before its widespread use. Further higher-quality studies are needed to better determine its role, the subset of patients that may benefit from its use, and its potential as an adjunct tool for treating other elbow conditions when treating elbow instability.

Ethics statement

This study did not require ethics approval as it used publicly available, de-identified data. No human participants or lab animals were directly involved. All procedures were conducted in accordance with relevant institutional and national ethical guidelines.

Credit author statement

Preksha Rathod – data curation, formal analysis, investigation, methodology, project administration, visualization, writing (original + review & editing).

Diego Martinez-Leyton – data curation, formal analysis, investigation, writing (review & editing).

Khaled Al-Awadhi – data curation, formal analysis, investigation, writing (review & editing).

Ali Lari – methodology, project administration, supervision, writing (review & editing).

Carlos Prada – methodology, project administration, supervision, writing (review & editing).

Source of funding

This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors. The authors have no affiliations.

References

  1. , , . Elbow instability: anatomy, biomechanics, diagnostic maneuvers, and testing. J Hand Surg Am. 2017 Feb 1;42(2):118.
    [Google Scholar]
  2. , , . Stability of the elbow: osseous constraints. J Shoulder Elb Surg. 2005 Jan 1;14(1)
    [Google Scholar]
  3. , , . Soft-tissue stabilizers of the elbow. J Shoulder Elb Surg. 2005 Jan 1;14(1)
    [Google Scholar]
  4. , , , , . Treatment of elbow instability: state of the art. J ISAKOS. 2021 Mar 1;6(2):102-115.
    [Google Scholar]
  5. , , . Rehabilitation of elbow instability. Hand Clin. 2020 Nov 1;36(4):511-522.
    [Google Scholar]
  6. , , . Complex elbow instability: surgical management of elbow fracture dislocations. EFORT open Rev [Internet]. 2017 May 1;1(5):183-190.
    [Google Scholar]
  7. , . Current concepts in the management of complex elbow trauma. Surgeon. 2009;7(3):151-161.
    [Google Scholar]
  8. , , , , . Unilateral hinged external fixator of the elbow in complex elbow injuries. Injury. 2004 Nov;35(11):1158-1166.
    [Google Scholar]
  9. , , , . [Hinged external fixation in orthopaedic and trauma surgery of the elbow] Acta Chir Orthop Traumatol Cech. 2013 Jan 1;80(6):391-395.
    [Google Scholar]
  10. , , . The management of acute and chronic elbow instability. Orthop Clin N Am. 2015 Apr 1;46(2):271-280.
    [Google Scholar]
  11. , , , , . Complications and range of motion of patients with an elbow dislocation treated with a hinged external fixator: a retrospective cohort study. Eur J Trauma Emerg Surg. 2022 Dec 1;48(6):4889-4896.
    [Google Scholar]
  12. , , , . Complications of hinged external fixators of the elbow. J Shoulder Elb Surg. 2008 May 1;17(3):447-453.
    [Google Scholar]
  13. , , , et al . Good functional recovery of complex elbow dislocations treated with hinged external fixation: a multicenter prospective study. Clin Orthop Relat Res. 2015;473(4):1451-1461.
    [Google Scholar]
  14. , , , et al . A hinged external fixator for complex elbow dislocations: a multicenter prospective cohort study. BMC Musculoskelet Disord. 2011 Jun 9;12(1):1-6.
    [Google Scholar]
  15. , , , . Complications of hinged external fixation compared with cross-pinning of the elbow for acute and subacute instability. Clin Orthop Relat Res. 2014;472(7)
    [Google Scholar]
  16. , , , , , , . Temporary spanning plate across the elbow for complex fractures of the distal humerus. BMC Musculoskelet Disord. 2021 Dec 1;22(1):1-8.
    [Google Scholar]
  17. , , . The management of elbow instability using an internal joint stabilizer: preliminary results. Clin Orthop Relat Res. 2014;472(7):2049.
    [Google Scholar]
  18. , , , et al . Multicenter trial of an internal joint stabilizer for the elbow. J Shoulder Elb Surg. 2017 Jan 1;26(1):125-132.
    [Google Scholar]
  19. , , , , . Treatment of traumatic elbow instability with an internal joint stabilizer. J Hand Surg Am. 2019 Feb 1;44(2):161.
    [Google Scholar]
  20. , , , , . Patient outcomes for the internal joint stabilizer of the elbow (IJS-E) J Shoulder Elb Surg. 2020 Jun 1;29(6)
    [Google Scholar]
  21. , , , , , . Acute complex instability of the elbow treated with internal joint stabilizer IJS-E system. Rev Española Cirugía Ortopédica Traumatol. 2021 Nov 1;65(6):433-442.
    [Google Scholar]
  22. , , , . Unique indications for internal joint stabilizer for elbow instability. J Shoulder Elb Surg. 2022 Nov 1;31(11)
    [Google Scholar]
  23. , , , , , . Internal joint stabilizer: a safe treatment for traumatic elbow instability. J Orthop Trauma. 2022 Sep;36(9):458-464.
    [Google Scholar]
  24. , , , et al . Short-term patient outcomes after placement of an internal joint stabilizer for terrible triad injuries: a multicenter study. J Hand Surg Am 2023
    [Google Scholar]
  25. , , , . Comparison of direct surgical cost and outcomes for unstable elbow injuries: internal joint stabilizer versus external fixation. JSES Int. 2023 Jul 1;7(4):692.
    [Google Scholar]
  26. , , , , . Outcomes of elbow fracture-dislocations treated with and without an Internal Joint Stabilizer of the Elbow (IJS-E): a retrospective cohort study. Shoulder Elbow. 2023 Jun 1;15(3):328-336.
    [Google Scholar]
  27. , , , . Residual elbow instability treated with a submuscular internal joint stabilizer: prospective and consecutive series with a minimum Follow-Up of 12 months. J Clin Med. 2024 Oct;13(22):6765.
    [Google Scholar]
  28. , , , , . A single surgeon experience with the internal joint stabilizer of the elbow across 56 cases. JSES Inter. 2024 Sep 10;9(1):244-249.
    [Google Scholar]
  29. , , , , , . External fixation about the elbow: indications and long-term outcomes. J Clin Orthop Trauma. 2024 Jan 1;48
    [Google Scholar]
  30. , , , , . Complications and range of motion of patients with an elbow dislocation treated with a hinged external fixator: a retrospective cohort study. Eur J Trauma Emerg Surg. 2022 Dec 1;48(6):4889-4896.
    [Google Scholar]
  31. , , , , , . Anatomy, definition, and treatment of the “terrible triad of the elbow” and contemplation of the rationality of this designation. Orthop Surg. 2015 Feb 1;7(1):13-18.
    [Google Scholar]
  32. , , , et al . What factors are associated with reoperation after operative treatment of terrible triad injuries? Clin Orthop Relat Res. 2021 Jan 1;479(1):119-125.
    [Google Scholar]
  33. , , , . Complications of treating terrible triad injury of the elbow: a systematic review. PLoS One. 2014 May 15;9(5)
    [Google Scholar]
  34. , , , et al . Functional elbow range of motion in children and adolescents. J Pediatr Orthop. 2020 Jul 1;40(6):304-309.
    [Google Scholar]
  35. , , , , , . Comparing internal and external stabilization for traumatic elbow instability: a systematic review. JSES Rev Reports, Tech 2024 Jan 18
    [Google Scholar]
  36. , , , , . Current perspectives on elbow dislocation and instability. Ann Jt. 2021 Jan 15;6(0):10.
    [Google Scholar]
  37. , , . Acute and chronic elbow instability: a review of mechanisms, patho-anatomy and management. Orthop Traumatol. 2020 Aug 1;34(4):197-205.
    [Google Scholar]
  38. , , , , , , . Incidence of elbow dislocations in the United States population. J Bone Jt Surg. 2012 Feb 1;94(3):240-245.
    [Google Scholar]
  39. , , , , . The internal joint stabilizer of the elbow: a systematic review of the clinical and biomechanical evidence. J Hand Surg Glob Online. 2023 Jan 1;6(1):62-67.
    [Google Scholar]
Show Sections