View/Download PDF
64 (); 47-50
doi:
10.1016/j.jor.2024.11.008

Translate:

A retrospective comparison of Coronal Plane Alignment of the Knee

Author affiliations
Georgetown University School of Medicine, 3900 Reservoir Rd NW, Washington DC, 20007, USA
Article History
Corresponding author(s)

⁎Corresponding author: Callie Fernandez. cmf304@georgetown.edu

Article tools · PDF & citations

Abstract

Abstract

Unicompartmental arthritic degeneration is treated by unicompartmental knee arthroplasties (UKA). The two current standards are mechanical alignment, where knee placement is perpendicular to the leg's mechanical axis and kinematic alignment, that consists of aligning the knee with the angles specific to the patient's innate bone structure. The purpose of this study was to compare knee alignment between mechanical and kinematic UKA.

A retrospective study at Medstar Washington Hospital Center from 2015 to 2022 identified 156 cases of knee arthroplasties. Of these, 95 had mechanical alignments and 61 had kinematic alignments. Patients were evaluated post-surgically for Coronal Plane Alignment of the Knee (CPAK). Analysis of post-operative joint x-ray imaging was performed, and the mechanical medial proximal tibial angle (MPTA) and lateral distal femoral angle (LDFA) were measured. The arithmetic hip knee ankle angle (aHKA) and joint line obliquity (JLO) were calculated.

The CPAK results for mechanically aligned group demonstrated an average MPTA of 87.12 (±3), LDFA average of 86.04 (±3), aHKA average of 0.62 (±4) and JLO average of 172.57 (±4). The CPAK results for the kinematically aligned group demonstrated an average MPTA of 86.96 (±3), LDFA average of 84.67 (±3), aHKA average of 2.09 (±4), and JLO average of 171.1 (±4). A two-sample t-test on this data demonstrates statistically significant p-values of 0.004 for LDFA, 0.03 for aHKA, and 0.02 for JLO all below the 0.05 significance level. Both cohorts only contained CPAKs alignment types I and III.

This study demonstrated that there is a statistically significant difference in knee alignment when comparing mechanically versus kinematically aligned knees which suggests that there is an advantage for patients that undergo kinematically aligned knee replacements.

Keywords

  • Unicompartmental knee arthroplasty
  • Unicompartmental kinematic alignment
  • Coronal Plane alignment of the knee
  • Mechanical UKA alignment
  • Kinematic UKA alignment
Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

Osteoarthritis (OA) is a common joint disorder involving inflammation and structural changes that can result in pain and a decreased ability to perform daily activities.1 OA is a chronic disease often associated with numerous comorbidities and a multifactorial pathogenesis, so strategies for prevention and early treatment are difficult.2 While symptoms and radiological changes often overlap in OA, some patients may exhibit radiologic change without experiencing symptoms.1 It has been found that the prevalence of OA increases with age and that women are at a higher risk than men.2 OA of the knee is a large contributor to the global burden of OA and often necessitates surgery. In 2017, there was an estimated 300 million patients living with hip or knee OA and it was ranked as the 11th highest contributor to global disability.1,3 As our population continues to age and obesity rates continue to rise, the burden of OA on the healthcare system will continue to increase, so it is imperative we determine how to best treat patients with knee OA.1

Arthritis of the knee can be treated with total knee arthroplasty (TKA) or unicompartmental knee arthroplasty (UKA). UKA is a surgical treatment designed to only replace one compartment of the knee with cartilage injury.4 Severe arthritis is often confined to a single knee compartment and studies have shown that UKA results in a faster recovery time with fewer complications and better function than TKA.5,6 Patients undergoing UKAs were more likely to report improved functionality.5 During a unicompartmental knee arthroplasty, a surgeon makes a small incision to remove any damaged cartilage or tissue and inserts a prosthetic piece to act as the patient's knee. Successful implants have a stable, long-term fix to the host's bone and optimize knee geometry to minimize contact and limit constraint.7

Currently, the standard procedure for UKA is mechanical knee alignment where tibial and femoral components are aligned perpendicularly to their respective bones in an attempt to maintain a neutral alignment of the knee.4,8 Patients have anatomical variations in their individual knees, so this technique can impact the orientation of the patient's knee leading to complications such as changes in joint kinematics, impacts on ligament balance, decreased quadriceps function, and altered patellar tracking.8 Studies have shown that mechanical alignment can result in ligament imbalances that are difficult to correct, eventually leading to abnormalities in the gait of arthroplasty patients.9 The shortcomings of mechanical alignment have resulted in new approaches being explored for knee replacement.

Kinematic alignment is an alternative individualized approach for knee arthroplasty that attempts to maintain the inherent anatomy of each patient's knee to produce greater patient satisfaction and function.10 In kinematic knee arthroplasty, the bone is resected to fit the implant in such a way that it is aligned with the pre-arthritic anatomy.10 This technique preserves the femoral flexion axis, so the articulation between the tibia and patella is maintained.11

Few studies have produced definitive findings comparing clinical outcomes of mechanical and kinematic knee alignment. Most studies focus on comparing alignment practices in TKA, not UKA.12 We recently completed a study suggesting that kinematic alignment significantly improved patient outcomes compared to mechanical alignment in knee arthroplasty,13 suggesting that kinematic UKA may be a viable clinical alternative to mechanical UKA.13 This study assessed both patient satisfaction via a post-operative assessment via the Forgotten Joint Score (FJS) and Oxford Knee Score (OKS) and the post-operative Coronal Plane Alignment of the Knee (CPAK).13 The objective of the present study was to reinforce these results with a larger sample size to gather more information and confirm our previous findings.

2

2 Methods

A retrospective cohort analysis was designed to identify 156 unicompartmental knee arthroplasties at Medstar Washington Hospital Center between January 2015 and September 2022. Of these cases, 95 had undergone a unicompartmental knee arthroplasty with mechanical alignment and 61 had undergone a unicompartmental knee arthroplasty with kinematic alignment. Postoperative analysis for CPAK was performed by four separate reviewers within the most recent (usually same day) post operative joint x-ray imaging.14 The first parameters measured were mechanical medial proximal tibial angle (MPTA) and lateral distal femoral angle (LDFA). Following these measurements, the arithmetic hip knee ankle angle (aHKA) and joint line obliquity (JLO) were then calculated via the equations MPTA-LDFA and MPTA + LDFA respectively.14

2.1

2.1 Surgical technique

Mechanical UKA was done using standard technique. This technique is dictated in the Arthrex UKA manual. In this technique, the tibia is cut first and the cut is made in line with the long bone mechanical axis. Gap balancing techniques are used to determine the femoral component valgus position and rotation.

Kinematic UKA was performed using Linked Anatomic Kinematic Arthroplasty (LAKA) technique.15 This technique was originally written and used for total knee arthroplasties in 2020 but was redesignated for partial knee arthroplasties in 2021.15 It confirms the valgus position of the unicompartmental femoral component using either navigation or caliper kinematic technique. After the valgus position is confirmed, this angle is then used to generate a tibial component position and then a gap to balance the femoral rotation. This is all done before making the cut so that the new prosthetic is aligned according to the knees previous anatomical position (see Table 1).

3

3 Results

The CPAK results for the mechanically aligned cohort (Table 2) demonstrated an average MPTA of 86.3 ( ± 2.6), an average LDFA of 85.6 ( ± 2.8), an aHKA average of 0.65 ( ± 4), and an average JLO of 171.9 ( ± 3.6). The CPAK results for the kinematically aligned cohort (Table 3) demonstrated an average MPTA of 86.5 ( ± 2.6), an average LDFA of 84.5 ( ± 2.8), an average aHKA of 2 ( ± 4), and an average JLO of 171 ( ± 3.7). A two-sample t-test of this date (Table 4) demonstrates a statistically significant p-value of 0.004 for LDFA (<0.05), 0.03 for aHKA (<0.05), and 0.02 for JLO (<0.05). Both the mechanically aligned and kinematically aligned cohorts were exclusively CPAK Type I and III (see Tables 5- 8).

Table 1 Kinematic demographics.
Kinematic Demographics (n = 56)
Variable Data
Sex, n (%)
Men 21 38 %
Women 35 63 %
Mean age, yrs 59
Mean age, yrs (SD) 10.8
Race, n (%)
White 13 23 %
African American 35 63 %
Asian 1 2 %
Other 5 9 %
Unknown 2 3 %
Table 2 Mechanical demographics.
Mechanical Demographics (n = 94)
Variable Data
Sex, n (%)
Men 43 46 %
Women 51 54 %
Mean age, yrs 55
Mean age, yrs (SD) 9.03
Race, n (%)
White 20 21 %
African American 65 69 %
Asian 0 0 %
Other 5 5 %
Unknown 3 3 %
Table 3 Mechanical postoperative CPAK measurements.
Mechanical (n = 94) MPTA LDFA aHKA JLO
Median 87.115 86.04 0.615 172.565
Average 86.2811 85.632 0.649 171.913
Standard Deviation 2.599 2.78 4.042 3.553
Table 4 Kinematic postoperative CPAK measurements.
Kinematic (n = 94) MPTA LDFA aHKA JLO
Median 86.96 84.665 2.095 171.1
Average 86.5375 84.498 2.039 171.0355
Standard Deviation 2.608 2.812 3.968 3.690
Table 5 Postoperative T-test results.
T-test results (kinematic vs. mechanical) MPTA LDFA aHKA JLO
p-value 0.7251 0.004357 0.03018 0.01895
Table 6 Kinematic CPAK change results.
Kinematic Change (n = 56) MPTA LDFA aHKA JLO
Median −1.15 −0.28 −1.15 −3.21
Average −1.59 −0.35 −1.24 −1.94
Standard Deviation 3.29 4.01 4.68 5.66
Table 7 Mechanical CPAK change results.
Mechanical Change (n = 94) MPTA LDFA aHKA JLO
Median −3.51 0.68 −3.81 −3.65
Average −3.82 0.5 −4.32 −3.31
Standard Deviation 4.95 4.2 6.98 5.96
Table 8 Change T-test results.
T-test results (kinematic vs. mechanical differences) MPTA LDFA aHKA JLO
p-value 0.003543 0.2627 0.004348 0.2024
4

4 Discussion

This study was intended to be a follow up study to a previous retrospective analysis done with another patient cohort from Washington Hospital Center.13 Our previous study included an n = 72, and concluded that patient reported outcomes, according to OKS, were significantly improved in kinematically aligned knees. The study also analyzed the post-surgical x-rays according to CPAK and found a significant difference between mechanically aligned and kinematically aligned knees with respect to the LDFA value. We predicted that a limited sample size was the reason for finding only one significant difference between the CPAK angle measurements.

For the current study, we were able to access a larger pool of patients undergoing UKA at Washington Medstar Hospital Center, with an n = 156, which is more than double our last study. The findings were in accordance with our hypothesis that a larger sample size led to more statistically significant results of the CPAK angles, specifically with a significant difference (p < 0.05) with LDFA, aHKA, and JLO. These findings confirm the goal of the kinematically aligned unicompartmental knee arthroplasty. The goal is such that the patient's original unique anatomy is considered, and the arthroplasty is done with respect to the patient's original anatomy allowing for improved post-surgical knee kinematics. This method accounts for more variation in anatomic structure and should result in a greater knee angle variation post-surgically.

This study further supported the idea stated in our previous paper that kinematics for partial knee arthroplasty may be even more important than for a TKA. In the operation for a partial arthroplasty, the parts that are being replaced must fit into the compartment of the original knee that will remain. Therefore, it is crucial to arrange the new prosthetic in accordance with the original knee angles of the patient. It allows for the partial arthroplasty to be more individualized, and for the new knee hardware to fit cohesively within the remaining parts of the patient's original knee structure. Our study shows that kinematic UKA does demonstrate a greater variation in knee angles with three out of the four knee angles being significantly different. This is contrasted to the mechanical UKA that has a standard procedure of defined knee angles, and therefore allows for less angle variability and ultimately lower patient reported outcomes as seen in our previous study.13 This study confirms that there is a benefit to kinematically aligned UKA regarding anatomic variability.

Two key limitations to note are the retrospective nature of this study and the use of a single surgeon for this patient cohort, which could potentially cause performance and selection bias. While this paper was able to collect a larger sample size than the previous study we connected, it is still important to note that the study was still limited by its sample size and its retrospective nature. It is also important to note the use of a single surgeon for this patient cohort, which could potentially cause performance and selection bias. Further prospective studies are needed to confirm the findings of our study. This is also necessary to assess variation across a wider range of patient demographics so that it could be more generalizable to the population at large.

5

5 Conclusion

This study found that there is a significant post-surgical difference in knee alignment comparing kinematic UKA to mechanical UKA. Specifically, the significant differences were between the LDFA, aHKA, and JLO angles of the knee. This suggests that the kinematical unicompartmental knee arthroplasty does consider the patient's original anatomy, and therefore has a wider-angle variation due to the wide anatomical variation.

The findings of this study suggest that kinematic alignment may be superior to the mechanical knee alignment for the general population due to its ability to account for a greater variety of anatomic structure.

CRediT authorship contribution statement

Callie Fernandez: Conceptualization, Methodology, Data curation, Formal analysis, Writing – original draft, Writing – review & editing, Visualization. Grace Knoer: Methodology, Formal analysis, Data curation, Writing – review & editing. Perry Diaz: Methodology, Formal analysis, Data curation, Writing – review & editing. Rachel Eom: Methodology, Formal analysis, Data curation, Writing – review & editing. Jasmine Gulati: Methodology, Formal analysis, Writing – review & editing, Visualization. Christopher P. Bellaire: Formal analysis, Data curation, Writing – review & editing, Supervision. Evan Argintar: Conceptualization, Methodology, Writing – review & editing, Supervision.

Ethical statement

1.Informed Consent: The retrospective nature of our study involves the use of pre-existing data, and no direct contact with participants occurred. As such, informed consent was not applicable. We have adhered to guidelines and regulations regarding the use of retrospective data while ensuring the privacy and confidentiality of individuals involved.2.Confidentiality: Stringent measures have been implemented to protect the confidentiality of the data used in this study. Personal identifiers have been appropriately anonymized or removed to prevent the identification of individuals. All data handling and storage procedures align with privacy regulations and ethical standards.3.Voluntary Participation: Given the retrospective design, there was no direct involvement or interaction with participants. The study was conducted using existing data, and individuals' participation was not influenced or required.4.Beneficence and Non-Maleficence: Throughout the study, we prioritized maximizing the benefits of the research while minimizing potential harm. Careful consideration was given to the impact of our findings on participants and the broader community.5.Ethics Review Board Approval: This retrospective study received IRB approval (ref: STUDY00007731) from the Georgetown-Medstar Review Board. The review process ensured that our study adheres to ethical standards and guidelines relevant to retrospective research.6.Transparency: We are committed to transparency in reporting our study. The manuscript includes a detailed description of the study methods, data sources, and statistical analyses. Any limitations or potential biases in the study are openly discussed.7.Respect for Participants' Autonomy: While direct participant interaction was not applicable to this retrospective study, we recognize the importance of respecting individuals' autonomy in research. Our study design and analyses were conducted with a commitment to ethical principles and consideration for the welfare of participants.8.Debriefing: As our study involved the use of existing data, direct debriefing of participants was not conducted.9.Continuous Monitoring: Throughout the research process, we implemented continuous monitoring to ensure ethical standards were maintained. Any unforeseen ethical issues were addressed promptly and appropriately.10.Publication and Dissemination: The manuscript submitted for publication accurately reflects the findings of our study. We commit to responsible and unbiased dissemination of information, and we acknowledge any limitations or potential biases present in our research.

Thank you for considering our manuscript for publication. We are confident that our retrospective study contributes valuable insights to the scientific community while upholding the highest ethical standards.

Funding

This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.

References

  1. , , , et al . The global burden of hip and knee osteoarthritis: estimates from the global burden of disease 2010 study. Ann Rheum Dis. 2014 Jul;73(7):1323-1330.
    [Google Scholar]
  2. , , . Strategies for the prevention of knee osteoarthritis. Nat Rev Rheumatol. 2016 Feb;12(2):92-101.
    [Google Scholar]
  3. , , , et al . Global, regional and national burden of osteoarthritis 1990-2017: a systematic analysis of the Global Burden of Disease Study 2017. Ann Rheum Dis. 2020 Jun;79(6):819-828.
    [Google Scholar]
  4. , , , , , , . Unicompartmental knee arthroplasty vs total knee arthroplasty for medial compartment arthritis in patients older than 75 Years: comparable reoperation, revision, and complication rates. J Arthroplasty. 2017 Jun;32(6):1792-1797.
    [Google Scholar]
  5. , , , et al . Total or Partial Knee Arthroplasty Trial - TOPKAT: study protocol for a randomised controlled trial. Trials. 2013 Sep 12;14:292.
    [Google Scholar]
  6. , , , et al . Gait comparison of unicompartmental and total knee arthroplasties with healthy controls. Bone Joint Lett J. 2016 Oct;98-B(10 Supple B):16-21.
    [Google Scholar]
  7. , , . Unicompartmental knee arthroplasty. J Am Acad Orthop Surg. 2008 Jan;16(1):9-18.
    [Google Scholar]
  8. , , , , , . The impact of mechanical and restricted kinematic alignment on knee anatomy in total knee arthroplasty. J Arthroplasty. 2017 Jul;32(7):2133-2140.
    [Google Scholar]
  9. , , , , , , . Kinematic alignment in total knee arthroplasty better reproduces normal gait than mechanical alignment. Knee Surg Sports Traumatol Arthrosc. 2019 May;27(5):1410-1417.
    [Google Scholar]
  10. , , , , , . Kinematic TKA using navigation: surgical technique and initial results. Orthop Traumatol Surg Res. 2016 Feb;102(1):99-104.
    [Google Scholar]
  11. , , , , . Accurate alignment and high function after kinematically aligned TKA performed with generic instruments. Knee Surg Sports Traumatol Arthrosc. 2013 Oct;21(10):2271-2280.
    [Google Scholar]
  12. , , , . Clinical outcomes of kinematic alignment versus mechanical alignment in total knee arthroplasty: a systematic review. EFORT Open Rev. 2020 Sep 10;5(8):486-497.
    [Google Scholar]
  13. , , , et al . A retrospective comparison of mechanically vs. kinematically aligned unicompartmental knee arthroplasties. J Orthop 2024:33-36.
    [Google Scholar]
  14. , , , , , . Coronal Plane assessment of the knee (CPAK) classification. Bone Joint J. 2021;103-B(2):329-337.
    [Google Scholar]
  15. , , , et al . Linked anatomic kinematic arthroplasty: a unique approach to balancing in total knee arthroplasty [published correction appears in J orthop. 2020 dec 15;24:291] J Orthop. 2020;20:198-203.
    [Google Scholar]
Show Sections