Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical research study
Current Issue
Editorial Board
Literature Review
Narrative review
Original Article
Research Article
Review Article
Short Report
Surgical techniques
Systematic Review and Meta-Analysis
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical research study
Current Issue
Editorial Board
Literature Review
Narrative review
Original Article
Research Article
Review Article
Short Report
Surgical techniques
Systematic Review and Meta-Analysis
View/Download PDF
65 (); 283-289
doi:
10.1016/j.jor.2025.06.015

Translate:

3D-printed titanium vertebra in the treatment of cervical spondylotic myelopathy: A comparative analysis of perioperative, radiographic, and clinical outcomes

Author affiliations
Department of Orthopaedics, Second Affiliated Hospital of Xi'an Jiaotong University, No 157, West Five Road, Xi'an, 710004, China
Department of Anesthesiology and Surgery, Second Affiliated Hospital of Xi'an Jiaotong University, No 157, West Five Road, Xi'an, 710004, China
Department of Epidemiology and Health Statistics, School of Public Health, Xi'an Jiaotong University Health Science Center, Xi'an, 710006, China
Article History
Corresponding author(s)

⁎Corresponding author: Leilei Pei. peileilei424@163.com

⁎⁎Corresponding author: Jun Dong. dongjun_orth@xjtu.edu.cn

Article tools · PDF & citations

Abstract

Abstract

Anterior cervical corpectomy and fusion (ACCF) using a titanium mesh cage (TMC) is associated with a high rate of subsidence. This study aims to evaluate the potential advantages of utilizing 3D-printed titanium vertebrae as an alternative to TMC in ACCF procedures.

A retrospective analysis was conducted on patients who underwent ACCF at our hospital between March 2017 and June 2023. Patient demographics, surgical parameters (operation duration and blood loss), functional assessments (Barthel score, Morse Fall Scale (MFS), anterior cervical corpectomy index (aCCI)), hospitalization duration, costs, postoperative complications, unplanned reoperations, ICU admissions, and patient-reported outcomes (Japanese Orthopedic Association (JOA) score, Visual Analog Scale (VAS) score, Neck Disability Index (NDI) score) were recorded. Radiographic outcomes, including C2-C7 Cobb angles, segmental lordosis, and subsidence, were assessed via lateral cervical spine X-rays. Statistical analysis was performed using the Chi-square test and Mann-Whitney test.

A total of 92 patients were included in the study, with 48 patients in the 3D-vertebra group and 44 in the TMC group. Baseline characteristics were comparable between groups. The 3D-vertebra group demonstrated significantly shorter operative time, reduced blood loss, and improved functional scores compared to the TMC group (p < 0.05). Postoperatively, the 3D-vertebra group exhibited lower JOA and VAS scores at both one-week and final follow-up. NDI scores were comparable at one week but were significantly higher in the TMC group at follow-up. While segmental lordosis remained similar between groups, C2-C7 Cobb angles showed significant differences at follow-up. The TMC group experienced an average subsidence of 2.5 mm, whereas the 3D-vertebra group had minimal subsidence.

The use of 3D-printed titanium vertebrae in ACCF surgery offers superior perioperative parameters, radiographic outcomes, and clinical scores compared to TMC implants. Further long-term studies are warranted to establish the extended benefits of 3D-printed vertebrae. Limitations should be considered when interpreting the findings, and prospective, randomized controlled studies are warranted to validate our conclusions.

Keywords

  • Cervical spondylotic myelopathy
  • ACCF
  • 3D-printed titanium vertebra
  • Titanium mesh cage
  • Subsidence
Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

Anterior cervical corpectomy and fusion (ACCF) is a widely accepted surgical approach for treating cervical spondylotic myelopathy (CSM), demonstrating favorable outcomes in neurological recovery and cervical alignment restoration.1 Traditionally, TMC implants combined with autologous bone grafts have been employed to enhance spinal stability and facilitate fusion.2 However, TMC implants have been associated with a high rate of subsidence, which can lead to recurrent neck pain and neurological deterioration.3,4 Previous studies, including research by Chen et al., have reported TMC subsidence rates as high as 79.7 %, highlighting concerns regarding its long-term efficacy.5 Subsidence may result in implant instability, screw loosening, and, in severe cases, anterior plate fracture, necessitating revision surgery.6,7

Biomechanical stability in ACCF is influenced by implant geometry and anatomical alignment.8 The human cervical vertebra exhibits structural variations, with the lower endplate of the adjacent upper vertebra forming a dome-like shape and the upper endplate of the adjacent lower vertebra angling at approximately 4°.9,10 This anatomical discrepancy poses challenges in achieving optimal contact between a manually trimmed TMC implant and the vertebral endplates.11 Furthermore, the sharp edges of TMC implants create a limited contact area, exacerbating the risk of subsidence under axial loading.

Additionally, the disparity in Young's modulus between TMC and native cervical bone induces stress shielding, further accelerating subsidence.12 Increased biomechanical stress on adjacent intervertebral discs in ACCF may also contribute to implant-related complications, including screw loosening.13,14

In response to these limitations, three-dimensional (3D) printing technology has emerged as a promising innovation in spinal surgery.15 3D-printed titanium vertebrae provide enhanced biocompatibility, improved anatomical conformity, and greater surface porosity, promoting osseointegration and reducing stress shielding. The expanded endplate contact surface in 3D-printed vertebrae optimizes load distribution, potentially mitigating subsidence and improving clinical outcomes compared to TMC implants.16,17

This retrospective study aims to compare perioperative parameters, radiographic outcomes (including Cobb angles), and clinical outcomes (such as blood loss and operation time) between 3D-printed titanium vertebrae and TMC implants in ACCF for CSM. By evaluating these factors, we seek to elucidate the advantages of 3D-printed titanium vertebrae and their role in enhancing the safety and efficacy of ACCF.

2

2 Methods

2.1

2.1 3D-printed titanium vertebra

The 3D-printed titanium vertebra (Aikang, China) features a 4° inclined slope at both ends, closely approximating the anatomical endplate slope of the adjacent vertebrae. This 8°-lordosis implant is designed to restore the normal segmental alignment of the cervical spine, in contrast to a manually trimmed titanium mesh cage (TMC). The height of the 3D-printed titanium vertebra ranges from 50 mm to 60 mm, with 2 mm increments. Available diameters include 10 × 12 mm, 12 × 14 mm, and 14 × 16 mm (Fig. 1).

3D-printed cervical implant characterization and postoperative imaging. (a) Anterior view; (b) Posterior view; (c) Lateral view; (d) Superior view; (e) Intraoperative placement; (f) Postoperative AP radiograph; (g) Postoperative lateral radiograph.
Fig. 1 3D-printed cervical implant characterization and postoperative imaging. (a) Anterior view; (b) Posterior view; (c) Lateral view; (d) Superior view; (e) Intraoperative placement; (f) Postoperative AP radiograph; (g) Postoperative lateral radiograph.
2.2

2.2 Participants

This study was conducted in accordance with the principles of the Declaration of Helsinki and was approved by the Ethics Committee of the Second Affiliated Hospital of Xi'an Jiaotong University (2023170). A total of 566 consecutive patients diagnosed with cervical spondylotic myelopathy (CSM) between March 2017 and June 2023 were screened. Among them, 92 patients who underwent anterior cervical corpectomy and fusion (ACCF) were included. Of these, 48 patients received 3D-printed titanium vertebrae (3D-vertebra group), while 44 patients were treated with TMC (TMC group). The case selection process is illustrated in the flowchart (Fig. 2).

Patient enrollment flowchart.
Fig. 2 Patient enrollment flowchart.

Inclusion Criteria: 1) Patients with complete clinical and follow-up data; 2) Patients with spinal cord compression caused by cervical disc herniation at two consecutive segments, as confirmed by preoperative imaging; 3) Patients presenting with varying degrees of limb weakness or numbness, sensory impairment, physiological reflex hyperactivity, upper limb swelling or pain, and unstable grip.

Exclusion Criteria: 1) Patients with a history of cervical spine surgery; 2) Patients with cervical spine fractures or tumors; 3) Patients with ossification of the posterior longitudinal ligament; 4) Patients with severe cardiac, pulmonary, hepatic, or renal diseases precluding surgical tolerance; 5) Patients with coagulation disorders; 6) Patients with psychiatric disorders or long-term use of antidepressants; 7) Patients with cranial disorders or peripheral neuropathies.

2.3

2.3 Surgical indication and technique

All procedures were performed by senior surgeon. Patients were positioned supine with their head and neck naturally extended. A transverse anterior cervical incision (3–5 cm) was made, exposing the carotid artery sheath and cervical visceral sheath. These structures were carefully dissected bluntly along their natural cleavage planes to access the vertebral body and anterior intervertebral disc. A retraction hook was used to gently mobilize the trachea and esophagus medially, while the carotid artery sheath was retracted laterally to the right.

Following exposure, the upper and lower intervertebral discs were identified, and the fibrous annulus was incised using a scalpel. The disc material was removed with nucleus pulposus forceps, and the disc and endplates were thoroughly scraped to the posterior vertebral margin. The posterior longitudinal ligament was carefully dissected using a neural stripper, and the posterior cortical bone was gradually excised using Kerrison rongeurs, creating a rectangular decompression trough. The trough was subsequently expanded to ensure complete decompression. After measuring the decompression trough height, an appropriately sized TMC or 3D-printed titanium vertebra was selected. Prior to implantation, the device was filled with autologous bone graft obtained during decompression. Fluoroscopic verification confirmed accurate placement. The surgical field was irrigated, and the wound was closed in layers. Standard postoperative care was administered, and patients were encouraged to perform normal neck movements one day postoperatively.

2.4

2.4 Data collection

All radiographic assessments were independently performed by two experienced spine surgeons who were blinded to the treatment group. Patient demographics, including gender, age, height, weight, smoking history, and medical history, were documented. The age-adjusted Charlson Comorbidity Index (aCCI) was used to assess comorbidities. Operative time, blood loss, and the number of decompressed vertebral levels were recorded. Postoperative complications, major and minor morbidity, unplanned reoperations, ICU admissions, hospital stay duration, and hospitalization costs were also noted. Functional assessments included the preoperative Barthel Index for activities of daily living and the postoperative Morse Fall Scale (MFS) for fall risk evaluation. The Barthel Index measures independence in 10 essential daily activities (e.g., feeding, walking). Each task scores 0–15 (max 100), where a preoperative BI < 60 signifies severe dependence, and postoperative gains ≥20 points denote clinically meaningful functional recovery in spinal disorders—reflecting regained autonomy even without full neurological resolution. The Morse Fall Scale quantifies fall risk in hospitalized patients through six weighted factors (e.g., history of falls, gait instability), with scores ranging 0–125 (higher = greater risk). In spinal surgery patients, a preoperative score >45 predicts postoperative mobility impairment, while a >10-point reduction indicates functional recovery, though absolute score interpretation requires context with neurological deficits. Clinical outcomes were measured using the 17-point Japanese Orthopedic Association (JOA) scale for CSM, Visual Analog Scale (VAS) for neck pain, and Neck Disability Index (NDI) at baseline and final follow-up.

2.5

2.5 Radiological assessment

Anteroposterior and lateral cervical spine X-rays were obtained preoperatively and at final follow-up. Preoperative MRI scans assessed spinal cord status. Radiological parameters included the C2–C7 Cobb angle and segmental lordosis (SL). The subtotal resected vertebra and adjacent vertebrae were considered a fixed unit (FU); for example, FU was C4–C6 when C5 was resected (Fig. 3). SL was defined as the angle between the superior endplate of the upper FU vertebra and the inferior endplate of the lower FU vertebra.

Radiographic measurement protocol. (a) Implant subsidence calculation: (H1+H2)/2; (b) Spinal angles: α (C2-C7 Cobb angle), β (segmental lordosis); (c) Implant design with 4° endplate inclination.
Fig. 3 Radiographic measurement protocol. (a) Implant subsidence calculation: (H1+H2)/2; (b) Spinal angles: α (C2-C7 Cobb angle), β (segmental lordosis); (c) Implant design with 4° endplate inclination.

Implant subsidence was determined by measuring the distance between the vertebral endplate and the implant's edge on X-rays taken within one week postoperatively and at final follow-up (Fig. 1). Subsidence was calculated as H = (H1+H2)/2, with significant subsidence defined as >2 mm18 (Fig. 3).

2.6

2.6 Statistical analysis

Categorical variables, such as gender, smoking history, and medical history, were analyzed using the Chi-square test. Nonparametric data were presented as M (P25, P75) and analyzed using the Mann-Whitney test. To reduce potential confounding inherent in retrospective studies, we performed multivariate linear regression analyses to adjust for key covariates, including age, age-adjusted Charlson Comorbidity Index (aCCI), bone quality, and follow-up duration. These variables were selected based on their known or suspected influence on surgical outcomes. All statistical analyses were conducted using SPSS software (version 26.0; SPSS Inc., Chicago, IL, USA). A P-value <0.05 was considered statistically significant.

3

3 Results

3.1

3.1 Baseline demographic and clinical data of patients included

A single-level anterior cervical corpectomy and fusion (ACCF) procedure was performed at the C4, C5, or C6 level. Patients in both groups had no postoperative adverse events, major and minor morbidity, unscheduled reoperation. The median age of patients in the 3D-vertebra group and TMC group was 56.5 (53, 68.75) years and 54.5 (50.00, 66.75) years, respectively (Table 1). There were no significant differences in age, height, body weight, anterior cervical corpectomy index (aCCI), gender, smoking history, and medical history between the two groups (P > 0.05) (Table 2). However, the 3D-vertebra group had shorter operation time, lower blood loss, Morse score, and Barthel score compared to the TMC group (P < 0.05) (Table 1). Hospital length, hospital cost, and post-operative admission to the intensive care unit (ICU) did not differ significantly between the two groups (P > 0.05) (Table 2).

Table 1 Baseline demographic and clinical characteristics (Mann-Whitney test).
3D-vertebra group(n = 48) TMC group(n = 44) Z P
Age (year) 56.5(53, 68.75) 54.5(50, 66.75) −1.436 0.151
Height (cm) 165(160, 172) 167.5(160, 176.75) −0.352 0.724
Weight (kg) 67(60, 75) 65.5(56, 75.75) −0.861 0.389
Operation time (min) 200(156.25, 220) 214.50(182.75, 263.25) −2.057 0.04
Blood loss (mL) 200(100, 400) 500 (300, 800) −3.685 0.00
aCCI 2(1, 3) 3 (1.25, 4.75) −1.904 0.057
Morse score 4.5(4, 5.75) 6 (5, 9) −3.87 0.00
Barthel score 82.5(71.25, 95) 70 (40, 88) −3.088 0.002
Hospital length (day) 13.5(11.25, 18) 16.00(13.25, 19.50) −1.805 0.071
Hospital cost (RMB /yuan ) 86607.6(73938, 101236.73) 76174.50(6391.78, 96918.48) −1.759 0.079
Average follow-up time(year) 2.06(1.35, 2.60) 3.94(2.90, 4.18) −6.758 0.00
Table 2 Comparison of clinical outcomes between groups (Chi-Square Test).
3D-vertebra group(n = 48) TMC group(n = 44) χ2 P
Gender(F/M) 17/31 19/25 0.581 0.446
Smoking History(N/Y) 22/26 19/25 0.065 0.798
Operation History(N/Y) 33/15 27/17 0.552 0.457
post-operative admission to ICU(N/Y) 48/0 43/1 1.103 0.294
3.2

3.2 Comparison of cervical spine functional characteristics

The comparison of cervical spine functional characteristics revealed that the 3D-vertebra group had a lower preoperative Japanese Orthopedic Association (JOA) score, indicating more severe symptoms in this group. However, at the last follow-up, patients in the 3D-vertebra group still had lower JOA scores than those in the TMC group (P < 0.05) (Table 3). No significant differences were observed in preoperative and one-week postoperative Neck Disability Index (NDI) scores between the two groups. However, at the last follow-up, the TMC group had higher NDI scores compared to the 3D-vertebra group (P < 0.05) (Table 3), suggesting significant improvement in cervical function in the 3D-vertebra group. Interestingly, the preoperative Visual Analog Scale (VAS) scores were comparable between the two groups (P > 0.05). However, patients in the 3D-vertebra group experienced significantly lower VAS scores at one-week postoperative and at the last follow-up (P < 0.05) (Table 3), indicating notable pain alleviation with the 3D-vertebra.

Table 3 Postoperative patient characteristics (Mann-Whitney test).
3D-vertebra group (n = 48) TMC group (n = 44) Z P
JOA
Preoperative 4(3, 6) 6.00(4.00, 9.00) −2.883 0.004
One-week postoperative 6(5, 7.75) 8(7, 10) −4.456 0.000
Last follow-up 8(7, 10.75) 10(9, 12) −2.8 0.005
NDI
Preoperative NDI 27(21, 30) 28.50(24.25, 34) −1.837 0.066
One-week postoperative NDI 19(14, 21.75) 19.00(15.25, 22.00) −0.149 0.882
Last follow-up NDI 10(7.25, 14.75) 13.5(10.00, 16.00) −2.315 0.021
VAS
Preoperative VAS 7(5, 8) 6.00(5, 7) −1.06 0.289
One-week postoperative VAS 3(2, 4) 4(3, 5) −4.297 0.00
Last follow-up VAS 1(1, 2) 1.5(1.00, 3.00) −3.257 0.001
3.3

3.3 Comparison of radiological data

There were no significant differences in SL at one-week postoperative and at the last follow-up between the two groups. Similarly, the C2-C7 Cobb angles were comparable between the two groups (P > 0.05) at one-week postoperative, but showed significant differences at the last follow-up (P < 0.05) (Table 4). During the follow-up period, the 3D-vertebra group exhibited minimal subsidence of the implant, while the TMC group experienced an average sinking of 2.5 mm (Table 4). Multiple linear regression model shows that the implant subsidence of implants is associated with implant type, patient age, smoking history, aCCI score, Morse score, and follow-up duration (Fig. 4).

Table 4 Comparative radiographic outcomes (Mann-Whitney test).
3D-vertebra group (n = 48) TMC group (n = 44) Z P
SL (°)
One-week postoperative 17.45(10.16, 25.01) 18.82(15.88, 24.66) −0.739 0.46
Last follow-up 14.12(9.36, 18.45) 11.27(5.38, 18.07) −1.321 0.187
Cobb angle (°)
One-week postoperative 14.31(10.11, 22.48) 16.35(12.00, 21.81) −0.72 0.471
Last follow-up 13.38(9.06, 16.29) 7.94(4.19, 13.74) −2.773 0.006
Subsidence of implant(mm) 0.00(0.00, 1.00) 2.50(1.00, 4.73) −4.907 0.00
Multiple linear regression model shows that the implant subsidence of implants is associated with implant type, patient age, smoking history, aCCI score, Morse score, and follow-up duration.
Fig. 4 Multiple linear regression model shows that the implant subsidence of implants is associated with implant type, patient age, smoking history, aCCI score, Morse score, and follow-up duration.
4

4 Discussion

TMC subsidence is a prevalent and consequential complication that may arise following ACCF.18 This subsidence not only results in the alteration of cervical spine curvature but also brings a heightened risk of severe neurological complications by pressure on the spinal cord and nerve roots.19 Prior research has indicated that the tilt angle of the TMC plays a significant role.20 When the tilt angle of the titanium cage is set at zero degree, the contact area between the TMC and vertebra becomes severely limited due to the inherent curvature of the cervical spine. This concentrated force at the contact interface facilitates the subsidence of the TMC into the vertebra. Moreover, clinical studies have established a strong correlation between the incidence of titanium cage subsidence and patient age and bone density.21 These factors, characterized by advanced age and reduced bone density, further elevate the susceptibility to subsidence.

Finite element analysis and examinations conducted on cervical cadaveric specimens have demonstrated that several primary factors contribute to cage subsidence in titanium cages.22,23 These factors are as follows: (1) Insufficient contact area: The interaction area between the titanium cage and the upper and lower vertebra is insufficiently small; (2) Mismatched anatomical morphology: The anatomical structure of the adjacent vertebra's endplates reveals a dome-shaped lower endplate of the upper vertebra and a 4–6° inclined slope-type upper endplate of the lower vertebra. This morphology does not align with the trimmed titanium cage and the upper and lower vertebra; (3) Bone quality and elasticity mismatch: The bone composition of the upper and lower vertebra exhibits significant variations and differs significantly from the elastic modulus of the titanium cage. With age, the trabecular bone content of the vertebral body decreases, particularly pronounced in perimenopausal women. Osteoporosis is prevalent among patients undergoing surgery for spinal cervical spondylosis, further heightening the risk.6 Thus, when utilizing a trimmed titanium cage with sharp edges and a limited contact area, penetration of the endplate and subsequent sinking into the vertebral body becomes more probable. Based on these findings, studies have proposed the manual construction of the titanium cage angle and careful determination of the spacing between the transverse midline crest and the anterior border of the vertebral body. However, achieving precise planning and execution through manual trimming of the titanium cage during surgery presents challenges. Even if the titanium cage is accurately trimmed intraoperatively, the issue of limited contact area between the cage and the endplate remains unresolved.

To address this concern, the utilization of 3D printing technology in the development of artificial vertebral bodies has emerged as a promising solution.24,25 This approach significantly enhances the contact area between the prosthesis and the upper and lower vertebral bodies while achieving a precise match with the physiological curvature of the cervical spine. As a result, post-surgery biomechanical stability of the patient's cervical spine can be substantially improved, thereby yielding a more reliable outcome. All surgeries were performed by the same senior surgeon to minimize operator-dependent variability. While the sequential introduction of 3D-printed implants (deployed after established titanium cage procedures) may reflect a learning curve effect, the superior outcomes in the 3D cohort likely also capture progressive refinements in surgical technique and patient selection over the study period. During long-term clinical follow-up, this clinical study found that patients with 3D-printed artificial vertebra showed negligible subsidence, whereas patients in the titanium mesh cage (TMC) group had an average subsidence of 2.5 mm. This strongly indicates that artificial vertebral bodies with a larger contact area have better clinical adaptability. The difference in median follow-up duration between groups (titanium cage: 3.94 years vs. 3D-printed: 2.06 years) reflects the sequential clinical introduction of these technologies: 3D-printed implants were only available at our institution from January 2020 onward. Crucially, cage subsidence—our primary endpoint—is predominantly an early radiographic event. Published evidence confirms that >90 % of clinically relevant subsidence occurs within 12 months postoperatively,26 a threshold surpassed by all patients in our 3D-printed cohort. Consequently, the observed reduction in severe subsidence in the 3D-printed group represents a valid evaluation of the technology's immediate biomechanical advantage. While extended surveillance remains necessary for long-term performance validation, this study definitively establishes the superior early stability of 3D-printed implants.

The apparent discrepancy—lower final JOA scores in the 3D-printed group despite superior structural outcomes—can be explained by two key factors. The first is preoperative neurologic deficit disparity. The 3D-printed cohort had significantly more severe baseline dysfunction (mean preoperative JOA: 4 vs. 6 p = 0.004). While both groups showed substantial improvement, the absolute final JOA remained marginally lower in the 3D group (8 vs. 10, p = 0.000). The second is differential follow-up effect. The longer follow-up in the two groups (median 2.06 vs. 3.94 years) conferred two advantages. We suppose that extended time allowed greater resolution of perioperative nerve root edema/irritation, enhancing late functional scores beyond the primary endpoint period. Also, titanium cage subsidence paradoxically stabilized over time by achieving new biomechanical balance at settled positions.

Furthermore, despite the higher cost of 3D-printed artificial vertebra compared to TMC, it was observed that 3D printing eliminates the need for intraoperative trimming, theoretically leading to a significant reduction in surgical time. This observation may be attributed to the significantly higher operative time and increased intraoperative blood loss in the titanium cage group, which could translate into higher anesthesia-related costs and potentially postoperative complications. From a clinical and economic perspective, the superior perioperative parameters and reduced implant subsidence associated with 3D-printed vertebrae may justify the higher initial device cost. Nonetheless, a formal cost-effectiveness analysis is warranted in future prospective studies. In this study, patients in the 3D-printed artificial vertebra group had an average reduction of approximately 14 min in surgical time compared to the TMC group. Surprisingly, intraoperative blood loss was also significantly reduced by approximately 300 ml in the 3D-printed artificial vertebra group when compared to the TMC group. This reduction in surgical time not only benefits patients by minimizing anesthesia duration but also results in faster postoperative recovery due to reduced blood loss. The findings are further supported by improved cervical-related functional indicators in the 3D-printed artificial vertebra group, such as lower Neck Disability Index (NDI) and Visual Analog Scale (VAS) scores compared to the TMC group, indicating superior long-term efficacy. However, there was no significant difference in discharge time between the two groups, possibly because the time of suture removal was primarily after two weeks postoperatively, and wound healing was not influenced by the implant. This partially explains the lack of significant difference in discharge time between the two groups.

When comparing SL and Cobb angle between the two groups, no significant differences were observed in SL at the initial and final follow-ups. However, at the final follow-up, it was found that patients in the 3D-printed artificial vertebra group demonstrated better Cobb angle restoration compared to the TMC group. The divergence in SL and Cobb angle reflects multi-level biomechanical interactions. SL focuses on localized disc space restoration at the instrumented level, heavily influenced by cage morphology and endplate preparation. In contrast, the Cobb angle integrates alignment contributions from adjacent mobile segments. The superior Cobb angle correction in the 3D cohort likely stems from the precise 30°–45° wedge designs of 3D implants counteracting focal kyphosis at pathologic segments, and reduced device subsidence preserving overall alignment over time. This suggests that while SL may be achieved with either implant, 3D printing enables patient-specific sagittal balance control (Cobb angle) through optimized load distribution across multiple segments. It was noted that both groups had lower Cobb angles at the final follow-up compared to the initial follow-up, which might be attributed to the wearing of cervical collars by patients for a short period postoperatively, causing some alteration in the physiological curvature of the cervical spine. This study also identified a certain degree of endplate subsidence when the artificial vertebral bodies were placed at the C5 and C6 levels. Possible reasons include the higher pressure at these cervical vertebral bodies and the greater inclination of the endplates of C5 and C6, making it challenging to position the artificial vertebral bodies optimally. While initial hypotheses focused on implant design superiority, our analysis reveals subsidence is multifactorial. Crucially, 3D implants demonstrated significant protective effects even after controlling for newly identified risks (smoking, mobility status, etc.). This suggests implant selection should be tailored to patient profiles. Future implant innovations must address modifiable risk factors.

This study has several limitations. First, its retrospective design inherently limits the ability to control for all potential confounding variables. Although we used multivariate regression models to adjust for known covariates such as age, comorbidities (aCCI), bone quality, and follow-up duration, unmeasured or unknown confounders may still exist. Additionally, the decision to use 3D-printed versus traditional TMC implants was made by the operating surgeon, which may introduce selection bias. Finally, the shorter follow-up period in the 3D-printed group could potentially underestimate the incidence of long-term complications, including delayed implant subsidence.

Despite demonstrating superior short-term radiographic outcomes, our findings must be interpreted within three key constraints. First, selection bias was inherent in our non-randomized design: 3D-printed cohort patients had more severe preoperative neurological deficits, though propensity-score adjustment confirmed outcome robustness. Second, differential follow-up (median 2.06 vs. 3.94 years) prevents definitive comparisons of late complications. Critically, the substantial cost premium of 3D-printed implants currently challenges cost-effectiveness, despite lower revision rates. Future studies should model lifetime cost-utility ratios at ≥5-year intervals. These limitations should be considered when interpreting the findings, and prospective, randomized controlled studies are warranted to validate our conclusions.

5

5 Conclusion

In conclusion, this study demonstrates that 3D-printed vertebra provides favorable clinical outcomes and lower implant subsidence rates. Limitations should be considered when interpreting the findings, and prospective, randomized controlled studies are warranted to validate our conclusions.

CRediT authorship contribution statement

Gelin Zhang: Data curation, Writing – original draft. Ting Zhang: Data curation, Writing – original draft. Xuyan Zhang: Visualization, Investigation. Yurui Guo: Visualization, Investigation. Liying Fan: Visualization, Investigation. Bin Cheng: Supervision. Leilei Pei: Software, Validation. Jun Dong: Conceptualization, Methodology, Writing – review & editing.

Availability of data and materials

All authors state that all data and materials as well as software application or custom code can support our published claims and comply with field standards.

Ethical statement

This study was performed in line with the principles of the Declaration of Helsinki. Approval was granted by the Ethics Committee of Second Affiliated Hospital of Xi'an Jiaotong University (2023170).

Guardian patient's consent

The data presented in this study are anonymized, and no personally identifiable information is included. Therefore, informed consent for publication was not required.

Funding statement

Key Project of Research and development Program of Shaanxi Province (2024SF-YBXM-196) was received in support of this work. No benefits in any form have been or will be received from a commercial party related directly or indirectly to the subject of this manuscript.

References

  1. , , , , , , . Results of surgical treatment for degenerative cervical myelopathy: anterior cervical corpectomy and stabilization. Spine. 2004;29:2493-2500.
    [Google Scholar]
  2. , , , , , . Multilevel corpectomy with anterior column reconstruction and plating for subaxial cervical osteomyelitis. Spine. 2016;41:E1088-e1095.
    [Google Scholar]
  3. , , , et al . Fusion and subsidence rates of vertebral body sliding osteotomy: Comparison of 3 reconstructive techniques for multilevel cervical myelopathy. Spine J. 2021;21:1089-1098.
    [Google Scholar]
  4. , , , , , , . Anterior cervical corpectomy and fusion versus anterior cervical discectomy and fusion for treatment of multilevel cervical spondylotic myelopathy: insights from a national registry. World Neurosurg. 2019;132:e852-e861.
    [Google Scholar]
  5. , , , et al . Subsidence of titanium mesh cage: a study based on 300 cases. J Spinal Disord Tech. 2008;21:489-492.
    [Google Scholar]
  6. , , , et al . Risk factors for subsidence of titanium mesh cage following single-level anterior cervical corpectomy and fusion. BMC Muscoskelet Disord. 2020;21:32.
    [Google Scholar]
  7. , , , et al . Complication and reoperation rates following surgical management of cervical spondylotic myelopathy in medicare beneficiaries. Spine. 2017;42:1-7.
    [Google Scholar]
  8. , , , , , . The effects of titanium mesh cage size on the biomechanical responses of cervical spine after anterior cervical corpectomy and fusion: a finite element study. Clin Biomech. 2022;91
    [Google Scholar]
  9. , , , , , , . Quantitative morphometric study of the subaxial cervical vertebrae end plate. Spine J. 2017;17:269-276.
    [Google Scholar]
  10. , , , , , , . Geometry of inferior endplates of the cervical spine. Clin Neurol Neurosurg. 2016;142:132-136.
    [Google Scholar]
  11. , , , et al . Construction of a new cervical anatomically adaptive titanium mesh cage based on measurements of cervical geometry: a morphological and cadaveric study. Exp Ther Med. 2021;22:1256.
    [Google Scholar]
  12. , , , , , . The effect of angular mismatch between vertebral endplate and vertebral body replacement endplate on implant subsidence. J Spinal Disord Tech. 2013;26:268-273.
    [Google Scholar]
  13. , , , , . A biomechanical analysis of four anterior cervical techniques to treating multilevel cervical spondylotic myelopathy: a finite element study. BMC Muscoskelet Disord. 2021;22:278.
    [Google Scholar]
  14. , , , . Relationship between screw sagittal angle and stress on endplate of adjacent segments after anterior cervical corpectomy and fusion with internal fixation: a Chinese finite element study. BMC Surg. 2017;17:119.
    [Google Scholar]
  15. , , , et al . 3D printing in orthopaedic surgery: a scoping review of randomized controlled trials. Bone Joint Res. 2021;10:807-819.
    [Google Scholar]
  16. , , , et al . A prospective randomized cohort study on 3D-printed artificial vertebral body in single-level anterior cervical corpectomy for cervical spondylotic myelopathy. Ann Transl Med. 2020;8:1070.
    [Google Scholar]
  17. , , , . 3D-printed titanium prosthetic reconstruction of the C2 vertebra: techniques and outcomes of three consecutive cases. Spine. 2020;45:667-672.
    [Google Scholar]
  18. , , , et al . Comparison of radiological and clinical outcomes of 3D-printed artificial vertebral body with titanium mesh cage in single-level anterior cervical corpectomy and fusion: a meta-analysis. Front Surg. 2022;9
    [Google Scholar]
  19. , , . Interbody cage placement without plate supplementation adjacent to plated segments in multilevel anterior cervical decompression and fusion. Spine. 2023;48:1245-1252.
    [Google Scholar]
  20. , , , et al . Factors affecting titanium mesh cage subsidence in single-level anterior cervical corpectomy and fusion for ossification of the posterior longitudinal ligament. J Orthop Surg Res. 2022;17:515.
    [Google Scholar]
  21. , , , , , . The predictive value of hounsfield units for titanium mesh cage subsidence after anterior cervical corpectomy and fusion. Front Surg. 2022;9
    [Google Scholar]
  22. , , , et al . Biomechanical effects of a novel anatomic titanium mesh cage for single-level anterior cervical corpectomy and fusion: a finite element analysis. Front Bioeng Biotechnol. 2022;10
    [Google Scholar]
  23. , , , et al . A novel anatomic titanium mesh cage for reducing the subsidence rate after anterior cervical corpectomy: a finite element study. Sci Rep. 2021;11
    [Google Scholar]
  24. , , , , , . 3D-printed titanium prosthetic reconstruction of unilateral bone deficiency after surgical resection of tumor lesions in the upper cervical spine: clinical outcomes of three consecutive cases and narrative review. Clin Spine Surg. 2023;36:256-264.
    [Google Scholar]
  25. , , , , , . Accuracy and safety of 3D printed surgical guides combined with monitored guidewires for placement of cervicothoracic pedicle screws: technical note. Neurochirurgie. 2023;69
    [Google Scholar]
  26. , , , , , . Cervical spine surgery complications and risks in the elderly. Spine. 2017;42:E347-e354.
    [Google Scholar]
Show Sections